Furuno MFD8 Manual de usuario

Installation Manual
Multi Function Display
Model MFD8/MFD12
SAFETY INSTRUCTIONS ............................................................................ i
SYSTEM CONFIGURATION ....................................................................... ii
EQUIPMENT LISTS.................................................................................... iv
1. MOUNTING............................................................................................ 1
1.1 Mounting Considerations..............................................................................................1
1.2 Flush Mounting .............................................................................................................2
1.3 Desktop Mounting.........................................................................................................4
2. WIRING .................................................................................................. 5
3. SETTING UP THE EQUIPMENT ......................................................... 11
3.1 Setup for Single MFD in the Network .........................................................................12
3.2 Setup for Multiple MFDs in the Network .....................................................................25
PACKING LISTS...................................................................................... A-1
OUTLINE DRAWINGS............................................................................. D-1
INTERCONNECTION DIAGRAM ............................................................ S-1
www.furuno.com
www.furuno.com
www.furuno.com
www.furuno.com


i
WARNING
Indicates a potentially hazardous situation which, if not avoided,
could result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation which, if not avoided,
may result in minor or moderate injury.
Warning, Caution
Mandatory Action
Prohibitive Action
SAFETY INSTRUCTIONS
The user and installer must read the appropriate safety instructions before attempting to install
or operate the equipment.
WARNING
ELECTRICAL SHOCK HAZARD
Do not open the equipment unless
totally familiar with electrical circuits.
Only qualified personnel should work
inside the equipment.
Turn off the power at the switchboard
before beginning the installation.
Fire or electrical shock can result if the
power is left on.
Be sure that the power supply is
compatible with the voltage rating of the
equipment.
Connection of an incorrect power supply
can cause fire or damage the equipment.
Standard
compass Steering
compass
MFD8
MFD12
0.90 m 0.60 m
0.85 m 0.55 m
CAUTION
Ground the equipment to prevent
electrical shock and mutual interference.
Observe the following compass safe distances
to prevent interference to a magnetic compass:
Use the proper fuse.
Use of an incorrect fuse may damage the equipment.

ii
SYSTEM CONFIGURATION
MFD8
RADAR SENSOR
DRS4A/DRS6A/DRS12A/DRS25A
OR
RADAR SENSOR
DRS2D/DRS4D
MONITOR
MU-155C/170C, etc.
VIDEO IN(CCD
CAMERA, MAX. 2)
LINE OUT
(SPKR, ETC.)
12-24 VDC*2
HUB -101
GPS NAVIGATOR
GP-320B/330B
AIS RECEIVER,
HEADING SENSOR or
EXTERNAL BUZZER
USB DEVICE
(MOUSE, KYBD)
NMEA 2000
(GP-330B, ETC.)
POWER SUPPLY UNIT*1
PSU-012 or PSU-013
: Standard Supply
: Optional Supply
: Local Supply
*1 PSU-012: w/DRS4A/6A/12A
PSU-013: w/DRS25A
*2 See the figure below for rectifiers used in the system.
MULTI FUNCTION
DISPLAY MFD8
FISH FINDER
(DFF series, ETR-6/10N, ETR-30N, FCV-1150)
12-24 VDC*2
DRS2D/4D
MFD8
RU-3423
DRS4A/6A/
12A
MFD8
PSU-012
RU-3423
PR-62
DRS25A
MFD8
PSU-013
RU-1746B
DRS4A/6A/
12A/25A
MFD8
PSU-012/013
RU-1746B
PR-62
LINE IN(MIC,
FUTURE USE)
FAX-30
FA- 50
Rectifiers used in the system

iii
MFD12
RADAR SENSOR
DRS4A/DRS6A/DRS12A/DRS25A
OR
RADAR SENSOR
DRS2D/DRS4D
MONITOR
MU-155C/170C, etc.
VIDEO IN (CCD
CAMERA, MAX. 2)
LINE OUT
(SPKR, ETC.)
12-24 VDC*2
HUB-101
GPS NAVIGATOR
GP-320B/330B
AIS RECEIVER,
HEADING SENSOR or
EXTERNAL BUZZER
USB DEVICE
(MOUSE, KYBD)
NMEA 2000
(GP-330B, ETC.)
POWER SUPPLY UNIT*1
PSU-012 or PSU-013
: Standard Supply
: Optional Supply
: Local Supply
*1 PSU-012: w/DRS12A
PSU-013: w/DRS25A
*2 See the table and figure below for
rectifiers used in the system.
MULTI FUNCTION
DISPLAY MFD12
12-24 VDC*2
DR2D/4D/
4A/6A
MFD12
RU-3423
DRS25A
MFD12
PSU-013
RU-1746B-2
PR-62
DRS12A
MFD12
PSU-012
PR-62 RU-3423
LINE IN(MIC,
FUTURE USE)
FAX-30
FA-50
FISH FINDER
(DFF series, ETR-6/10N, ETR-30N, FCV-1150)
Rectifiers used in the system

iv
EQUIPMENT LISTS
Standard supply
*See the lists at the back of this manual.
Optional supply
Name Type Code No. Qty Remarks
Multi Function
Display MFD8 - 1 Choose one.
MFD12 -
Instalaltion mate-
rials CP19-00900 000-011-780 1 set For MFD8, CP19-00901*, cables
CP19-01000 000-011-781 For MFD12, CP19-01001*, cables
Spare Parts SP19-00701 001-028-020 1 set For MFD8, fuses
SP19-00801 001-028-030 For MFD12, fuses
Accessories FP19-01101 001-023-060 1 set Panel remover
Name Types Code No. Remarks
Cable Assy MJ-A7SPF0007-050C 000-154-028-10 5 m, NMEA0183, w/connector
M12-05BM+05BF-010 000-167-962-10 φ6, 1 m, NMEA2000, w/micro
connectors
M12-05BM+05BF-020 000-167-963-10 φ6, 2 m, NMEA2000, w/micro
connectors
M12-05BM+05BF-060 000-167-964-10 φ6, 6 m, NMEA2000, w/micro
connectors
M12-05BFFM-010 000-167-965-10 φ6, 1 m, NMEA2000, w/micro
connector
M12-05BFFM-020 000-167-966-10 φ6, 2 m, NMEA2000, w/micro
connector
M12-05BFFM-060 000-167-967-10 φ6, 6 m, NMEA2000, w/micro
connector
CB-05PM+05BF-010 000-167-968-10 φ10, 1 m, NMEA2000, w/
micro connectors
CB-05PM+05BF-020 000-167-969-10 φ10, 2 m, NMEA2000, w/
micro connectors
CB-05PM+05BF-060 000-167-970-10 φ10, 6 m, NMEA2000, w/
micro connectors
CB-05BFFM-010 000-167-971-10 φ10, 1 m, NMEA2000, w/
micro connector
CB-05BFFM-020 000-167-972-10 φ10, 2 m, NMEA2000, w/
micro connector
CB-05BFFM-060 000-167-973-10 φ10, 6 m, NMEA2000, w/
micro connector

v
Cable Assy MOD-Z072-020+ 000-167-175-10 LAN cross, 4-pair, 2 m
MOD-Z072-050+ 000-167-176-10 LAN cross, 4-pair, 5 m
MOD-Z072-100+ 000-167-177-10 LAN cross, 4-pair, 10 m
MOD-Z073-030+ 000-167-171-10 LAN straight, 2-pair, 3 m
MJ-A6SPF0016-005C 000-159-689-11 For FAX-30, ETR6N/10N con-
nection
NMEA Connector LTWSS050505FMF-
TS001
000-168-603-10 NMEA 2000 distributor, micro
style
LTWMC-05BMMT-
SL8001
000-168-604-10 NMEA 2000 terminator, male,
micro style
LTWMC-05BFFT-
SL8001
000-168-605-10 NMEA 2000 terminator,
female, micro style
LTWNC050505FMF-
TS001
000-160-507-10 NMEA 2000 distributor, mini
style
LTWMN-05AMMT-
SL8001
000-160-508-10 NMEA 2000 terminator, mini
style
LTWMN-05AFFT-
SL8001
000-160-509-10 NMEA 2000 terminator,
female, mini style
In-line Terminator FRU-0505-FF-IS 000-172-037-10 NMEA 2000 connector w/ter-
minator, micro style
DVI-D Cable DVI-D/D SINGLELINK 000-149-054-10 5 m, for Multi-purpose LCD
connection
DVI-D/D S-LINK 000-150-200-10 10 m, for Multi-purpose LCD
connection
External Buzzer OP03-136 000-086-443
Junction Box FI-5002 000-010-765 For FI-50 series connection
Rectifier RU-3423 000-030-443 w/o PSU-012
PR-62 000-013-484 100VAC, w/PSU-012
000-013-485 110VAC, w/PSU-012
000-013-486 220VAC, w/PSU-012
000-013-487 230VAC, w/PSU-012
RU-1746B-2 000-030-439 220VAC
-For PSU-012 and MFD
-PSU-013
Network Hub HUB-101 -
Joint Box TL-CAT-012 000-167-140-10 For LAN cable extension
Connector Boot OP19-7 001-028-090
Operator’s Manual OME-4440 000-167-802
NMEA 2000 Inter-
face Unit
IF-NMEA2K1 -
Name Types Code No. Remarks

1
1. MOUNTING
1.1 Mounting Considerations
When selecting a mounting location for the MFD8/12, keep the following in mind:
• The temperature and humidity at the mounting location should be moderate and stable.
• Locate the unit away from exhaust pipes and ventilators.
• The mounting location should be well ventilated.
• Mount the unit where shock and vibration are minimal.
• Keep the unit away from electromagnetic field generating equipment such as motors and gen-
erators.
• For maintenance and checking purposes, leave sufficient space at the sides and rear of the
unit and leave slack in cables. Minimum recommended space is shown the outline drawing for
the display units.
• Do not mount the MFD8/12 on the overhead.
• A magnetic compass will be affected if the display unit is placed too close to it. Observe the
compass safe distances shown in the SAFETY INSTRUCTIONS to prevent disturbance to the
magnetic compass.
•For the flush mount, make sure the mounting location is flat.
The MFD8/12 can be flush mounted in a console or panel, or mounted on a desktop.
MFD12
MFD8

2
1.2 Flush mounting
1. Prepare a cutout in the mounting location using the template sheet (supplied) for the MFD8 or
12.
2. Remove the front panel from the MFD by unfastening the catches at the rear of the panel, in
the order as shown in the figure below.
Note: Catches are tight to unfasten. Take care not to break the panel.
3. Attach the mounting sponge to the display unit.
4. Fix the display unit by using four self-tapping screws (supplied).
5. Attach the front panel to the display unit.
How to detach the front cover from the mounting place.
To detach the front panel after mounting the unit, use the remover (supplied) as below. Note that
the front cover may be damaged if the following is not done.
1. Set the remover to a notch on the lower side of the unit.
Mounting
sponge
Front panel
Cutout
Display unit
(ex. MFD12)
Self-tapping screws
(4 pcs.)
MFD, rear view
(catches’ locations and order to unfasten)
1
2
3
4
5
6
7
1
8

3
2. Pull the remover to raise the panel slightly. Do this for all notches on the lower side of the unit.
3. Insert the remover to the space at the both sides of the unit, and pull the remover to raise the
panel slightly.
4. Use your hands to detach the front panel at lower side of it.
Otros manuales para MFD8
5
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Manuales populares de Impresora todo en uno de otras marcas

Triumph Adler
Triumph Adler DC 2016 Manual

Epson
Epson WorkForce WF-2510 Guía del usuario

Epson
Epson Stylus Scan 2000 Manual de instalación y operación

Epson
Epson PictureMate Snap PM 240 Manual de instrucciones

Konica Minolta
Konica Minolta bizhub C35 Manual de usuario

Brother
Brother MFC-J430w Manual de usuario











