Furuno IB-781 Manual de usuario

CREDIT CALL ADAPTER
IB-781

C
9-52, Ashihara-cho,
Nishinomiya, Japan
Telephone: 0798-65-2111
Telefax: 0798-65-4200
Your Local Agent/Dealer
All rights reserved.
PUB. No. OME-56094
IB-781
(
TATA
)
FIRST EDITION : DEC. 1999
Printed in Japan

i
SAFETY INSTRUCTIONS
WARNING
Immediately turn off the power at the
switchboard if water leaks into the
equipment or something is dropped in
the equipment.
Continued use of the equipment can cause
fire or electrical shock. Contact a FURUNO
agent for service.
Do not disassemble or modify the
equipment.
Fire, electrical shock or serious injury can
result.
Do not place liquid-filled containers on
the top of the equipment.
Fire or electrical shock can result if a liquid
spills into the equipment.
Immediately turn off the power at the
switchboard if the equipment is emitting
smoke or fire.
Continued use of the equipment can cause
fire or electrical shock. Contact a FURUNO
agent for service.
Make sure no rain or water splash leaks
into the equipment.
Fire or electrical shock can result if water
leaks in the equipment.
ELECTRICAL SHOCK HAZARD
Do not open the equipment.
Only qualified personnel
should work inside the
equipment.
WARNING
Keep heater away from equipment.
A heater can melt the equipment's power
cord, which can cause fire or electrical
shock.
Use the proper fuse.
Fuse rating is shown on the equipment.
Use of a wrong fuse can result in equip-
ment damage.
Do not operate the equipment with wet
hands.
Electrical shock can result.
CAUTION
Do not use the equipment for other than
its intended purpose.
Use of the equipment as a stepping stool,
for example, can result in personal injury
or equipment damage.
A warning label is attached to the
equipment. Do not remove the label.
If the label is missing or illegible,
contact a FURUNO agent or dealer.
WARNING
To avoid electrical shock, do not
remove cover. No user-serviceable
parts inside.
Name: Warning Label (1)
Type: 86-003-1011-0
Code No.: 100-236-230
Safety Instructions for the Operator

ii
WARNING
Turn off the power at the switchboard
before beginning the installation.
Fire or electrical shock can result if the
power is left on.
Do not install the equipment where it
may get wet from rain or water splash.
Water in the equipment can result in fire,
electrical shock or equipment damage.
Be sure that the power supply is
compatible with the voltage rating of
the equipment.
Connection of an incorrect power supply
can cause fire or equipment damage. The
voltage rating of the equipment appears
on the label above the power connector.
ELECTRICAL SHOCK HAZARD
Do not open the equipment
unless totally familiar with
electrical circuits and
service manual.
Only qualified personnel
should work inside the
equipment.
CAUTION
Observe the following compass safe
distances to prevent interference to a
magnetic compass:
Ground the equipment to
prevent electrical shock and
mutual interference.
IB-781
Standard Steering
compass compass
0.65 m 0.45 m
Safety Instructions for the Installer

iii
TABLE OF CONTENTS
FOREWORD..................................................................................................................... iv
SYSTEM CONFIGURATION ............................................................................................. v
EQUIPMENT LIST............................................................................................................ vi
1. OPERATIONAL OVERVIEW ...................................................................................... 1
1.1 Control Description.....................................................................................................................1
1.2 Turning the Power On/Off...........................................................................................................2
1.3 Telephone Credit Card Call Procedure ......................................................................................3
1.4 Fax Credit Card Call Procedure .................................................................................................5
1.5 How to Dial PIN No. ...................................................................................................................8
1.6 Telephone, Fax Usage ...............................................................................................................8
2. MAINTENANCE, TROUBLESHOOTING ................................................................... 9
2.1 Cleaning .....................................................................................................................................9
2.2 Replacement of Fuse .................................................................................................................9
2.3 Troubleshooting..........................................................................................................................9
3. INSTALLATION ........................................................................................................ 11
3.1 Mounting...................................................................................................................................11
3.2 Wiring........................................................................................................................................13
3.3 TEL, FAX Port Setup on FELCOM 80, FELCOM 81 ...............................................................16
SPECIFICATIONS ....................................................................................................... SP-1
OUTLINE DRAWING..................................................................................................... D-1
INTERCONNECTION DIAGRAM .................................................................................. S-1

iv
FOREWORD
FURUNO Electric Company thanks you for purchasing the FURUNO IB-781 Credit Call Adapter.
The IB-781 is designed to meet the rigorous demands of the marine environment. However, no
machine can perform to the utmost of its ability unless it is properly installed and maintained.
Please carefully read and follow the recommended procedures for installation, operation and
maintenance to get maximum performance from this equipment.
Features
The IB-781 Credit Call Adapter and its companion card reader connect between the TEL or FAX
port on the FURUNO FELCOM 80 or FELCOM 81 Inmarsat B Mobile Earth Station and a
telephone or fax to provide credit card calling by telephone or fax.
The major features of the IB-781 are
•Fully complies with Inmarsat B technical standards (SDM Issue 3.0).
•Reads most major credit cards.
•4 (FELCOM 80) or 5 units (FELCOM 81) may be connected.
•Operates independently of the card reader plugged into the TEL, FAX connector on the
FELCOM 80, FELCOM 81.

v
SYSTEM CONFIGURATION
System configuration with FELCOM 80
: Option
COMMUNICATION
UNIT
IB-280
CREDIT CALL
ADAPTER
IB-781
JUNCTION BOX
IB-311
TEL or FAX
CARD READER
System configuration with FELCOM 81
: Option
COMMUNICATION
UNIT
IB-281
ANTENNA
UNIT
IB-180
ANTENNA
UNIT
IB-181
CREDIT CALL
ADAPTER
IB-781
TEL or FAX
CARD READER
Ship's Mains 100/200 VAC,
1φ, 50/60 Hz
Ship's Mains 100/200 VAC,
1φ, 50/60 Hz
ANTENNA
UNIT
IB-180
ANTENNA
UNIT
IB-180

vi
EQUIPMENT LIST
Standard Supply
Name Type Qty Remarks
Credit Call
Adapter IB-781 1 w/Card Reader MCT-1504-4, mounting base
Installation
Materials,
Spare Parts
–1 set
Installation Materials
1) Connection cable RS-232C (0.5 m, IB-781 ↔Card Reader)
2) Modular jack cable (2 core, 3 m, IB-781 ↔FELCOM)
3) Power cable (3 m)
4) Tapping screw (4 pcs.)
Spare Parts
1) Fuse (1A)

1
1. OPERATIONAL OVERVIEW
1.1 Control Description
The IB-781's lone control is a POWER switch, and it is located on the rear panel. LEDs on the
front panel light or flash according to equipment status. The 1A fuse on the rear panel protects the
equipment from overvoltage and equipment fault.
FURUNO
CREDIT CALL ADAPTER IB-781
POWEROK ERROR
Lights when equipment is powered.
•Lights when card is successfully read.
•Flashes for equipment error.
• Flashes for equipment error.
• Lights for card reading error.
RS-232C connector
(Connects to CARD
READER connector
on IB-781.)
Not used.
CARD
READER
LED (Lights when card reader is ready for operation.)
Front view
LINE TEL/FAX CARD READER 1A POWER
100V-220VAC 50-60Hz
LINE connector
(Connects to TEL or FAX connector
on FELCOM 80/FELCOM 81).
TEL/FAX connector
(Connects to telephone
or fax.)
CARD READER connector
(Connects to RS-232C
connector on card reader.)
POWER connector
(Connects to
AC ship's mains.)
POWER switch
Fuse holder (1A fuse)
Ground terminal
DC IN RS-232C
Rear view

2
1.2 Turning the Power On/Off
The IB-781 checks itself and the card reader when powered on, in the following sequence.
Turn on the POWER switch on the rear
panel.
The POWER LED on the front panel lights.
The diagnostic test lights and extinguishes the
OK and ERROR LEDs in order and then
lights and extinguishes them together.
The card reader is checked for proper
connection. If proper, a beep sounds for
0.25 sec. and then the LED on the card
reader lights.
The above tests last about eight seconds.
For any fault the OK and ERROR LEDs on
IB-781 flash.
Should this occur, turn off the IB-781, check
the connection with the card reader and then
turn on the IB-781 again.