Furun 406080A-FUR Manual de usuario

AC/DC POWER SUPPLY UNIT
406080A-FUR
OPERATOR'S MANUAL
www.furuno.com
Model


i
Important notice
General
• This manual has been authored with simplified grammar, to meet the needs of
international users.
• The operator of this equipment must read and follow the descriptions in this
manual. Wrong operation or maintenance can cancel the warranty or cause
injury.
• Do not copy any part of this manual without written permission from FURUNO.
• If this manual is lost or worn, contact your dealer about replacement.
• The contents of this manual and equipment specifications can change without
notice.
• The example screens (or illustrations) shown in this manual can be different
from the screens you see on your display. The screens you see depend on your
system configuration and equipment settings.
• Save this manual for future reference.
• Any modification of the equipment (including software) by persons not
authorized by FURUNO will cancel the warranty.
• All brand and product names are trademarks, registered trademarks or service
marks of their respective holders.

ii
How to discard this product
Discard this product according to local regulations for the
disposal of industrial waste. For disposal in the USA, see the
homepage of the Electronics Industries Alliance
(http://www.eiae.org/) for the correct method of disposal.
In the European Union
The crossed-out trash can
symbol indicates that all
types of batteries must not be
discarded in standard trash,
or at a trash site. Take the
used batteries to a battery
collection site according to your national legislation and the
Batteries Directive 2006/66/EU.
In the USA
The Mobius loop symbol
(three chasing arrows)
indicates that Ni-Cd and
lead-acid rechargeable
batteries must be recycled.
Take the used batteries to a
battery collection site according to local laws.
In the other countries
There are no international standards for the battery recycle
symbol. The number of symbols can increase when the other
countries make their own recycle symbols in the future.
Cd
Ni-Cd Pb

iii
Safety instructions
The following general safety precautions must be observed during all
phases of operation, service and repair of this equipment. Failure to
comply with these precautions or with specific warnings elsewhere in
this manual violates safety standards of design, manufacture and
intended use of the equipment. FURUNO assumes no liability for the
customer's failure to comply with these requirements.
GROUND THE EQUIPMENT
To minimise shock hazard, the equipment chassis and cabinet must be
connected to an electrical ground and the cable instructions must be
followed.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Do not operate the equipment in the presence of flammable gases or
fumes. Operation of any electrical equipment in such an environment
constitutes a definite safety hazard.
KEEP AWAY FROM LIVE CIRCUITS
Operating personnel must not remove equipment covers. Component
replacement and internal adjustment must be made by qualified
maintenance personnel. Do not service the unit with the power cable
connected. Always disconnect and discharge circuits before touching
them.
OBSERVE MARKED AREAS
Under extreme heat conditions do not touch areas of the
unit that are marked with this symbol, as it may result
in injury.
COMPASS SAFE DISTANCE
Minimum safety distance: 30 cm (standard), 20 cm (steering)
DISCONNECT THE AC POWER BEFORE REMOVING THE
PROTECTIVE LID
Hazardous voltage exists behind the protective lid.
Failure to comply with the rules above will void the warranty!
Warning!Never insert or remove a power supply while its
power switch is in the On (|) position. Make sure the
power switch is Off (O) first.

iv
About the manual
Intended readers
This manual is an installation and user manual for the
406080A-FUR AC/DC Power Supply Unit. It is important that
you observe all safety requirements listed in the beginning of
this manual, and operate the 406080A-FUR AC/DC Power
Supply Unit according to the instructions and guidelines in this
manual. All installation must be done by qualified service
personnel.
Manual overview
This manual has the following chapters:
•Introduction contains a description of the principle of
operation and uses and features of the power supply.
•Installation contains step-by-step guidelines how to install
the power supply as a stand-alone unit or in a combined
setup and describes the connectors.
•Service and repair contains information on support, how to
return units for repair and instructions how to exchange the
fuses.
• Appendices with Technical specifications, information
about the wall mount tray and wiring 4 or more units.
Typography
In this manual, typography is used as indicated below:
Bold is used to emphasize words and to indicate connector
names of the unit.
Italic is used to emphasize the paragraph title in cross-
references.

v
Table of contents
Chapter 1 Introduction
General description .........................................................1
Features ................................................................................... 2
Block diagram ......................................................................... 3
System configuration .............................................................. 4
Chapter 2 Installation
Unpacking .......................................................................5
Installing the 406080A-FUR AC/DC Power Supply Unit ...... 6
Installing 2 or 3 406080A-FUR AC/DC Power Supply Units
...................................................................................... 15
Chapter 3 Service and repair
Support, repair and service ...........................................19
Exchanging the fuses ............................................................ 20
Returning units for repair ...................................................... 21
App. A Technical specifications...............................................23
App. B Wall-mount tray (option)
Overview ......................................................................25
App. C Special installation
Wiring 4 or more 406080A-FUR AC/DC Power Supply
Units .....................................................................27
App. D Declaration of conformity
OEM declaration ..........................................................29
CE (LVD & EMC) .......................................................30

Table of contents
vi
Packing lists ...................................................................................PL-1

1
Chapter 1
Introduction 1
1.1 General description
1.1.1 Positioning of connectors
When mounted vertically the 406080A-FUR AC/DC Power Supply Unit
fulfills IP32 in areas with more than 42 V and IP22 in other areas.
The 406080A-FUR AC/DC
Power Supply Unit can deliver
300 W output power on
average with a peak of 370 W
for a minimum of
2 minutes.This is useful for
MF/HF applications and DSC
transmissions of 2 minutes
duration. It is AC powered
with a battery switch-over function. The 406080A-FUR AC/DC Power
Supply Unit has an on/off switch. It is lit when the power is turned on.
All connectors are placed at the same end of the power supply to simplify
mounting and installation. The connector panel is protected by a
transparent lid. To secure an installation with heavy cables a cable-relief
bracket can be installed.

Chapter 1: Introduction
2
1.2 Features
The 406080A-FUR AC/DC Power Supply Unit has the following
features:
Two DC connectors, output, range: 28.7 V - 31.2 V
Output power 300 W continuous, 370 W peak (2 min., 100-240 VAC)
or 270 W continuous, 333 W peak (2 min., 90-100 VAC)
Daisy-chaining of up to three units to give up to 1110 W.1
AC input (100-240 VAC operating) with fuse (6.3 A) with Power
Factor Correction
Automatic detection of input voltage range
AC alarm and Short circuit protection
Over-temperature protection (shutdown with automatic restart)
Switch over to battery power in case of AC supply failure
No forced cooling required
On/off switch
IP 32 for internal high voltage areas (>42 V), IP 22 in other areas
when vertically mounted (wall) and connector panel is facing down2
Approval and certification: IEC 60945 Maritime approval
1. Output power capability depend on the mounting position (horizontal or
vertical), input voltage, ambient temperature and ventilation at the place of
installation.
2. IP 30 and IP 20 for other mounting positions.