Connections for standby power to a building's electrical system must be
made by a qualified electrician and must comply with all applicable laws and
electrical codes. Improper connections can allow electrical current from the
generator to back feed into the utility lines. Such back feed may electrocute
utility company workers or others who contact the lines during a power
outage, and when utility power is restored, the generator may explode, burn
or cause fires in the building's electrical system.
WARNING!
WARNING!
WARNING!
WARNING!
1. General safety
Exhaust gas contains poisonous carbon monoxide.
Never run the generator in an enclosed area. Be sure to provide adequate
ventilation. When installed in ventilated protection are to be observed.
The muffler becomes very hot during operation and remains hot for a while
after stopping the engine.
Be careful not to touch the muffler while it is hot. Let the engine cool before
storing the generator indoors. The engine exhaust system will be heated
during operation and remain hot immediately after stopping the engine.
To prevent scalding, pay attention to the warning marks attached to the
generator.
Gasoline is extremely flammable and explosive under certain conditions.
Refuel in a well ventilated area with the engine stopped.
Keep away from cigarette, smoke and sparks when refueling the generator.
Always refuel in a well-ventilated location.
Wipe up spilled gasoline at once.
WARNING! BEFORE USING THE MACHINE READ THE INSTRUCTION MANUAL
CAREFULLY!
Our generators are designed to give safe anddependable service if operated
according to instructions.
Read and understand the anual before operating the generator . Failure to
do so could result in personal injury or equipment damage.
FUBAG
FUBAGm
www.fubag.ru
Omperator's anual

- 2 -
-
-5
-
-
-
-
-
-
Always make a pre-operation inspection before you start the engine. You
may prevent an accident or equipment damage.
Place the generator at least m away from buildings or other equipment during operation.
Operate the generator on a level surface. If the generator is tiled, fuel spillage may result.
Know how to stop the generator quickly and understand operation of all the controls.Never permit
anyone to operate the generator without proper instructions.
Keep children and pets away from the generator when it is in operation.
Keep away from rotating parts while the generator is running.
The generator is a potential source of electrical shocks when misused; do not operate with wet
hands.
Do not operate the generator in rain or snow and do not let it get wet.
- The power generator is a mains replacement that generates electrical power for supply to a mobile
distribution system.
- The power generator must be operated outdoors within the prescribed voltage, output and rated
speed limits (see type plate).
- The power generator must not be connected to other electrical supply systems or electric generation
systems (e.g. other power generators).
- The power generator may not be used in environments where there is a risk of explosion.
- The power generator may not be used in environments where there is a risk of fire.
- The power generator must be operated in accordance with the conditions set out in the technical
documentation.
- All improper use of the power generator including all uses not described in these instructions will
constitute unauthorized incorrect usage for which the manufacturer is not legally liable.
- Operation in environments where there is a risk of explosion and fire.
- Operation in enclosed areas and under direct exposure to rain or snowfall.
- Operation without the requisite safety precautions and connected to existing supply network
systems.
- Spraying with high-pressure cleaners or fire extinguishing equipment.
- Non-compliance with regular servicing requirements.
- Failure to carry out measurements and checks for early detection of defects.
- Know and apply the Prevention of Injury regulations and the safety instructions for the power
generator.
- Understand and be able to practically implement the technical documentation.
- The operator must know the functions of, and be able to use, the components of the power generator.
- The operator must wear the appropriate personal safety equipment.
- The labelling on the electrical generator must be complete and maintained in a readable condition.
- Constructive changes may not be carried out on the electrical generator.
- The rated speed of the motor has been set during manufacture and may not be changed.
- The operating safety and correct functioning must be checked before and after each use.
- No naked flames, lights or spark-emitting appliances may be used within the hazard area of the
power generator.
- Smoking within the hazard area of the power generator is strictly forbidden.
- During operation, the power generator must be protected from dirt and foreign matter.
- The power generator may only be transported when cold.
- The power generator may only be lifted using the carry handles intended for this purpose.
- The electrical safety must be checked before each operational use.
- The appliance may not be covered. The air intake may not be blocked or obstructed.
- When starting, the load may not be connected.
- Only certified and approved cables may be used for the wired network.
- The power drawn may not exceed the maximum rated power.
www.fubag.ru
Omperator's anual
WARNING!

- 3 -
2. Safety symbols
- The power generator may not be operated without the sound absorber.
- The power generator may not be operated without the air filter or with the air filter cover open.
- The generator's tank may not be refilled during operating.
- The tank may not be refilled when the power generator is hot.
- The power generator may not be cleaned and serviced when in operation; when hot.
-Always remove spark plug connector prior to commencing servicing and repair work.
- The power generator must be shut down when not required for periods longer than 30 days.
- The power generator must be stored in a dry enclosed room.
www.fubag.ru
Omperator's anual
1. Precautions that involve your safety
2. Start and run the generator outdoors. Do not run the generator in an
enclosed area, even if doors or windows are open
3. To reduce the risk of serious injury, avoid attempting to touch the hot
surface
4. Units should not be operated or stored in wet or damp conditions or on
highly conductive locations such as metal decking and steel work
5. Could not use under the rain
6. Fuel and its vapors are extremely flammable and explosive. Fire or
explosion can cause severe burns or death
7. Ear protection
8. Read carefully and understand operator manual prior to operation of this
product. Follow all warnings and instructions
.
.
.
.
.
.
.
.

- 4 -
www.fubag.ru
Omperator's anual
4. Description
3. Specifications
The manufacturer reserves himself the right to make the manual's content or
function change without any preliminary notification of the users.
power generator
1. SOCKET
2. CIRCUIT BREAKER
3. FUEL GAUGE
4. DIGITAL DISPLAY
5. FUEL TANK CAP
6. ENGINE SWITCH
7. FUEL VALVE
8. CHOKE LEVER
9. RECOIL STARTER
10. OIL DRAIN PLUG
11. OIL FILLER CAP
12. EARTH TERMINAL
ATS SOCKET
14. BATTERY
13.
Model BS 4400 BS 5500 BS 5500 A ES BS 6600 BS 6600 A ES BS 6600 DA ES
Generator type
Rated frequency/ IP
Rated voltage 230 V 1~ / 400 V 3~
Max. output 4,4 kVA 5,5 kVA 5,5 kVA 6,5 kVA 6,5 kVA 7,5 kVA
Rated output 4,0 kW 5,0 kW 5,0 kW 6,0 kW 6,0 kW 5,6 kW
Cos φ 0,8
Motor type
Starter electic starter recoil starter
Motor power 9,3 hp
Tank capacity
Noise level
Relative humidity
Dimension, LxWxH
Weight 74 kg 77 kg 85 kg 80 kg 87 kg 90 kg
0-75%
700х530х570 mm
10,3 hp 10,9 hp
25 l
97dB(A)
230 V 1~
1
1-cylinder, 4-stroke, air-cooled
recoil starter electic starter
Synchro
50 Hz / IP 23

- 5 -
www.fubag.ru
Omperator's anual
15. AIR CLEANER
16. SPARKPLUG
17. MUFFLER
A - Digital display
B - AC voltage indicator
C - Frequency indicator
D - Hour indicator
E - Low lubricant alert
F - Select button
DIGITAL DISPLAY

- 6 -
www.fubag.ru
Omperator's anual
5. Pre-Operation checks
Check engine oil
-
-.
-
.
-.
Before checking or refilling oil, be sure the generator is
put on a stable and level surface with engine stopped.
Remove oil filler cap and check the engine oil level
If oil level is below the lower level line, refill with
suitable oil (see table below) to upper level line. Do not
screw in the oil filler cap when checking oil level
Change oil if contaminated
Ambient
temperature
Single grade
Multi grade

- 7 -
www.fubag.ru
Omperator's anual
Check engine fuel
WARNING!
-
.
-.
-.
-
.
-
.
-.
-.
-
.
-
.
Do not refuel while smoking or near open flame or
other such potential fire hazards. Otherwise fire
accident may occur
Close fuel cock before refueling with fuel
Do not refill tank while engine is running or hot
Be careful not to admit dust, dirt, water or other
foreign objects into fuel
Wipe off spilt fuel thoroughly before starting
engine
Keep open flames away
Check fuel level at fuel gauge
If fuel level is low, refill with unleaded automotive
gasoline
Be sure to use the fuel filter screen on the fuel filter
neck
Fuel tank capacity 25l.
Checking components
Check following items before starting engine
fuel leakage from fuel hose
bolts and nuts for looseness
components for damage or breakage
:
-.
-.
-.
FULL
EMPTY

- 8 -
www.fubag.ru
Omperator's anual
Checking generator surroundings
WARNING!
Make sure you review each warning in order to prevent fire hazard
- Keep area clear of inflammables or other hazardous materials.
- Keep generator at least 3 feet (1 meter) away from buildings or other structures.
- Only operate generator in a dry, well ventilated area. Keep exhaust pipe clear of foreign objects.
- Keep generator away from open flame.
- Keep generator on a stable and level surface.
- Do not block generator air vents with paper or other material.
.
6. Operating procedures
Starting
(а) .
(b) .
(с)
.
Set the engine switch to "ON" position
Open the fuel cock
Set the choke lever to "CLOSE" (arrow mark). Not
necessary if the engine is warm
ОТКРЫТО
ЗАКРЫТО

- 9 -
www.fubag.ru
Omperator's anual
(d)
.
(е)
.
(f) .
(а)
.
(b) .
(с) .
:
Pull the starter handle slowly until resistance is felt.
This is the "Compression" point. Return the handle to its
original position and pull swiftly.
Do not fully pull out the rope. After starting, allow the
starter return to its original position while still holding the
handle. If the engine fails to start after several attempts,
repeat above procedures with choke lever returned
"OPEN" position
After the engine started, return the choke lever
gradually to "OPEN" position
Warm up the engine without load for a few minutes
Check the digital display for proper voltage. This generator is thoroughly tested and adjusted in
the factory.
If the generator does not produce the specified voltage, consult your nearest FUBAG generator
dealer
Turn off the switch(es) of the electrical appliance(s) before connecting to the generator
lnsert the plug(s) of the electrical appliance(s) into the receptacle
WARNING
- Be sure to ground the generator if the connected electrical equipment is grounded.
Using electric power
ОPEN