FS FS-S038-2IO-24F Manual de usuario

24 DOME FIBER OPTICAL SPLICE CLOSURE
24-FASER DOM LWL-SPLEIßMUFFE
DÔME POUR ÉPISSURES OPTIQUES 24 FIBRES
V1.0
Quick Start Guide
Guide de Démarrage Rapide
Quick Start Anleitung
FS-S038-2IO-24F

Introduction
Thank you for choosing the dome fiber optical splice closure (FOSC) & fiber optical splice tray (FOST).
This guide is designed to familiarize you with the layout of the FOSC&FOST and describes how to
deploy them in your network.
EN
1
FS-S038-2IO-24F
CF-24F-FS

EN
2
Accessories
Seal Tape x1 adhesive tape x10 Heat Shrinkable
Protective Sleeve x48
Installation Requirements
To ensure the technical requirements, the following instructions must be
followed:
Fibers with protective coat are fixed with nylon tie at the entrance of FOST.
Grommet should be pressed from inside to outside in order to properly install FOST.
Straight-through and reserved fibers with protective coat should be winded to the fiber holding
tray.
The internal tighteners and fixing nut of reinforced core must be well tightened.
Seal fitting is installed neatly and smoothly.
The heat shrinkable fixing sleeve must be reliable and sealed completely.

EN
3
Installation
Open the Closure
FOSC cover
FOSC hoop (left) FOSC hoop (right)
Hoop connector
Hoop fixing bolt
Bracket
Base
Entry/exit tube(mass)
Hoop locking system
Determine the Length of Fiber Cable
Fiber cable
Temp.
locating mark
100mm sealing and fixing length of fiber cable inside inlet/outlet tube
1750mm length of protective coat of fiber cable to be stripped off
150mm length of fiber with protective coat
(the distance from fixing point of fiber cable to fixing point of FOST)
1600mm length of protective coat of fiber to be stripped
off(to be spliced and winded inside the FOST)
2(A)
Demount hoop fixing bolt and pull hoop locking system out, then proceed in demounting the hoop.
Pull the FOSC cover upwards out.
NOTE: If the weather condition is not good enough, then a tent must be pitched for
waterproof and dustproof.
Grommet
Fiber holding tray
FOST
Fixing device for
reinforced core
Big gasket
ring
Fixing seat
Entry/exit tube

EN
4
NOTE: 1. Reserve enough length of fiber cable to be spliced.
2. Stripping length also could be decided by customers according to installation
requirement.
If all fibers are for branch splicing, please refer to 2(A) for stripping length. If some fibers are for
straight-through, while others are for branch splicing, please refer to 2(B) for stripping length.
Fiber cable
Temp.
locating mark
100mm sealing and fixing length of fiber cable inside inlet/outlet tube
150mm length of fiber with protective coat(the distance
from fixing point of fiber cable to fixing point of FOST)
100mm length of fiber with protective coat to be cut
1600mm length of protective coat of fiber to be
stripped off(branch splicing)
1850mm length of fiber cable
to be stripped off (for straight-through after being winded)
Temp.
locating mark
2(B)
Entry terminal fiber cable Stripping terminal fiber cable
Temp.
locating mark Cutter
Strip off Fiber Protective Coat of Fiber Cable
NOTE: If it is difficult to pull all the protective coat of fiber cable at one time, strip it off
section by section to avoid fiber breakage.
Strip off protective coat of fiber cable from the temp locating mark with the cutter and the stripper,
please refer above drawing for stripping length. Stripping length also could be decided according to
installation requirement.

EN
5
1. Wind 2 layers of insulation tape on protective coat of fiber core for protection. Meanwhile, get rid of
the stuffing to separate fiber core and clean them. Form a ring with the diameter of 100mm or so and
fix it on the fiber temporarily by adhesive tape.
2. Depending on fiber cable stripped, the following two cases are available:
①All fibers are to be branched after being spliced completely.
②Some of fibers are for straight-through after being winded, while the others are for branch splicing.
3. The FOSC is provided with 3 single entry/exit tubes which suit for single fiber cables with max.
diameter ф20mm and 1 mass entry/exit tube which suits for 1piece of fiber cable with max. diameter
ф 20mm or 2 pieces of fiber cables with max. diameter ф 15mm or multi-pieces of fiber cables with
short diameter.
4. Mass entry/exit tube is required if some fibers are for straight-through.
5. The corresponding entry/exit tube cover could be slightly knocked out with screwdriver from
inside to outside according to number and diameter of fiber cable required.
6. Reserve reinforced core in 70mm length and cut off the unnecessary ones.
NOTE: Entry/exit tubes are to be selected accurately to make it easy for splicing and sealing.
Separate Fiber Cores
Adhesive tape
Reinforced core
70mm
Fiber with
protective coat
Fiber cable (1)
Fiber cable (2)
Fiber cable (3)
Fiber
Fiber with
protective coat
Adhesive tape
Adhesive tape
Fiber
Straight-through fiber
with protective coat
Fiber
Reinforced core

EN
6
Fix Reinforced Core & Pyrocondense, Fix and Seal fiber cable
NOTE: 1. Fixing nut of reinforced core should be tightened.
2. While heating, heat shrinkable fixing tube should shrink evenly, and there should be no
bubbles, pores and other defects inside the tube.
1. Insert fiber cable into the corresponding heat shrinkable fixing tube, further insert the them into
entry/exit tube at the bottom of FOSC.
2. Demount fixing nut of reinforced core with a special wrench (plastic one), which is to be inserted
into the fixing slot afterward and tighten it. Then re-tighten it with a metal wrench (the metal wrench
is to be provided by operator).
3. Hitch heat shrinkable fixing sleeve to the fiber cable till its root by hand.
4. Please refer to above drawing for installing branching clip.
5. Heat heat shrinkable fixing sleeve with fire sprayer to make it hugging entry/exit tube and fiber
cable to reach complete sealing.
Adhesive tape
Braching clip
Fiber sprayer
Fiber cable (3)
Fiber cable (2)
Fiber cable (1)
Heat shrinkable
fixing sleeve (mass)
Base
Entry/exit
tube cover
Heat shrinkable fixing
sleeve (single)
Bracket Fiber with
protective coat
Fixing device for
reinforced core
Fiber
FOST cover
FOST
Fiber holding tray
Adhesive tape
Fiber
Fiber
Fiber with
protective coat
Adhesive tape

EN
7
Install Heat Shrinkable Protective Sleeve and House fibers
Check up Comprehensively
When having completed splicing the fibers, the first fiber ring should be housed on the farthest side
of FOST, the remaining fiber optic should be winded, forming a ring with diameter not less than
80mm. then put it into FOST (Fiber Optic Splice Tray) together with heat shrinkable protective sleeve.
(Firstly fix heat shrinkable protective sleeve into the slot, then enlarge the diameter of fiber ring
properly.)
NOTE: Pay attention to the twist and bend of fiber.
Nylon tieNylon tie
Fiber
(bunchy or ribbon)
Heat shrinkable
protective sleeve
Grommet
FOST
Fiber
(bunchy or ribbon)
Fixing slot of heat
shrinkable protective
sleeve (bunchy or ribbon)
Fiber with
protective coat
Fiber with
protective coat
Reinforced core
Base
Fiber cable (1)
Fiber cable (3)
Fiber cable (2)
Branching clip
Fiber holding tray
Straight-through fiber
with protective coat
Nylon tie
Fixing device
for reinforced core
Seal fitting
Reinforced core
Fiber with
protective coat
Bracket
Heat shrinkable
fixing sleeve (single)
Heat shrinkable
fixing sleeve (mass)
Grommet
FOST cover
FOST
Nylon tie
Fiber with
protective coat

EN
8
Assemble FOSC Housing and Fix FOSC
1. Put desiccant into FOSC.
2. Put FOSC cover on base directly.
3. Install plastic hoop between FOSC cover and base, tighten hoop locking system, which is to be
fixed by hoop fixing bolt then.
4. FOSC installation:
①Aerial application: fix metal hoop and transom to the pole. Please refer to above Drawing;
②Wall mounting application: fix the bracket on the wall with bolt. (metal hoop is not required.)
③Underground application: metal hoop is not required.
Online Resources
Download
Help Center
Contact Us
https://www.fs.com/products_support.html
https://www.fs.com/service/fs_support.html
https://www.fs.com/contact_us.html
NOTE: 1. Pay attention while installing plastic hoop.
2. The specification of bolt for fixing the bracket is M8.
Bracket (metal)
Base Heat shrinkable
fixing sleeve (single)
Entry/exit tube
Hoop (left)
Hoop locking system
Hoop fixing bolt
Label
Hoop (right)
Fiber
Hoop (metal)
Transom (metal)
FOSC cover

9
DE
Einführung
Vielen Dank, dass Sie sich für die Dom LWL-Spleißmuffe FOSC und die Spleißablage FOST entschieden
haben. Diese Anleitung soll Sie mit dem Aufbau von FOSC und FOST vertraut machen und beschreibt,
wie Sie diese in Ihrem Netzwerk einsetzen können.
FS-S038-2IO-24F
CF-24F-FS
Tabla de contenidos
Idiomas:
Otros manuales de Recinto de FS