Fruitland RCF 172 Guía de instalación

FRUITLAND VACUUM PUMP
Operation and Maintenance
Attention:
Read owner’s manual fully before operating pump.
Failure to do so can result in severe pump damage and may void warranty.
FM-VPM-2020
324 Leaside Avenue
Stoney Creek, ON Canada L8E 2N7
Tel: 905-662-6552 / TF: 1-800-663-9003
Fax: 905-662-5412
www.fruitlandmanufacturing.com
RCF 172, 344 Models


3
Fruitland Manufacturing • Toll Free: 1-800-663-9003 • www.fruitlandmanufacturing.com
CONTENT
Fruitland Vacuum Pump Designations ........................................................... 4
Pump Operation & Maintenance..................................................................... 5
Installation & Adjustments....................................................................... 6
Lubrication & Approved Oils.................................................................... 9
Oil Pump Adjustment .............................................................................. 11
Vacuum Pump Flushing Procedure ....................................................... 12
Vacuum Pump & System Maintenance ................................................. 14
Vacuum Pump Drive Systems ................................................................. 16
Fruitland Right Angle Gearbox ............................................................... 20
Fruitland Hydraulic Motor ....................................................................... 21
Drive Shaft Installation & Phasing .......................................................... 23
Vane Wear Measurement ....................................................................... 24
Trouble Shooting Pump & System Malfunctions ................................. 27
Vacuum Actuated Cooling System (VACS) ............................................. 28
RCF 172 Pump Parts & Dimensions ............................................................... 29
RCF 172 Exploded View ........................................................................... 30
RCF 172 Detailed Item Numbers ............................................................ 31
ELIM A172-PT-L Exploded View .............................................................. 34
ELIM A172-PT-L Detailed Item Numbers ............................................... 35
ELIM G172 Exploded View ....................................................................... 36
ELIM G172 Detailed Item Numbers ....................................................... 37
ELIM H172-PT-L Exploded View .............................................................. 39
ELIM H172-PT-L Detailed Item Numbers ............................................... 40
RCF 344 Pump Parts & Dimensions ................................................................ 41
RCF 344 Exploded View ............................................................................ 42
RCF 344 Detailed Item Numbers ............................................................ 43
ELIM A344-PT Exploded & Dimensional Views ..................................... 46
ELIM A344-PT Detailed Item Numbers .................................................. 49
ELIM G172 Exploded & Dimensional Views .......................................... 51
ELIM G172 Detailed Item Numbers ....................................................... 52
ELIM G344 Exploded & Dimensional Views .......................................... 55
ELIM G344 Detailed Item Numbers ....................................................... 57
Truck Mounting Instructions For Eliminator Systems With Angle Drive .... 59
Warranty ........................................................................................................... 60
Serial Number .................................................................................................... 62

4Fruitland Manufacturing • Toll Free: 1-800-663-9003 • www.fruitlandmanufacturing.com
FRUITLAND VACUUM PUMP DESIGNATIONS
Ordering Information:
1. Choose Rotation L or R
2. Choose drive option A or H; OR specify belt drive or pulley
Sample Model Code:
RCF344LUH – Rotary Compressor Fiber Vane Pump model 344 series pump with left hand
rotation, four-way valve on top and Hydraulic Drive Adapter.
RCF Model Nomenclature:
RCF 344 L U H
MODEL
RFC - Rotary Compresor Fibre (Vane)
SERIES
172
344
ROTATION
L - Counter Clockwise
R - Clockwise
DRIVE OPTIONS
BLANK - Bare Shaft
H - Hydraulic Drive Adapter
A - Right Angle Drive Adapter
VALVE OPTIONS
U - Top Valve (Upper)
S - Side Valve
Model 172 Model 344
RCF 344 L H
MODEL
RCF - Rotary Compresor
Fibre (Vane)
SERIES
172
344
DRIVE OPTIONS
BLANK - Bare Shaft
H - Hydraulic Drive Adapter
A - Right Angle Drive Adapter
ROTATION
L - Counter Clockwise
R - Clockwise

5
Fruitland Manufacturing • Toll Free: 1-800-663-9003 • www.fruitlandmanufacturing.com
PUMP OPERATION &
MAINTENANCE

6Fruitland Manufacturing • Toll Free: 1-800-663-9003 • www.fruitlandmanufacturing.com
INSTALLATION & ADJUSTMENTS
Lifting
Lift pump by eye bolts, if provided, or with slings around body of pump close to legs.
Mounting
Secure pump unit to at sturdy surface with four bolts, washers and lock washers, through
holes in the base of the pump legs.
RPM
Fruitland Vacuum Pumps should never exceed the RPM stated on the plate tag (pump damage
is possible). Pump may be run 20% slower than the stated RPM on the tag if required.
*Vacuum-Pressure Gauge:
Required to SAFELY operate and monitor the systems performance. Locate this gauge at an
Operational location and or after the primary and secondary shut-os/scrubbers to prevent
failure due to foreign material.
*Pressure & Vacuum Relief Valves:
Regulates the operating Pressure & Vacuum levels within the system. There should be a min-
imum of two of each relief valve within your system. One set of reliefs upon the tank and one
set of reliefs near the pump. All Relief Valves are rated per CFM (cubic feet per minute) and
must be sized accordingly to your vacuum pump system and as recommended by the vacu-
um tank manufacturer.
WARNING
Read Operations and Maintenance Manual fully before operating the
vacuum pump. Failure to do so may result in severe system damage
that may cause severe injury, death, and void the pumps warranty.
WARNING
AlwaysverifythecorrectReliefvalve settingswiththetankmanufacturer.
Failure to do so may cause catastrophic failure, injury and/or death.

7
Fruitland Manufacturing • Toll Free: 1-800-663-9003 • www.fruitlandmanufacturing.com
Vacuum & Pressure Relief Adjustment
*Fruitland Pressure Relief - PART # PRV2”
Release the anti-rotation screw (1) - turn the upper ring (3) - ro-
tate clockwise - CW - to increase pressure OR rotate counter
clockwise - CCW - to decrease pressure in vessel.
When the desired pressure in the vessel is achieved, slightly turn
the upper ring (3) until the attened spot upon the wheel’s shaft
is achieved. Tighten the anti-rotation screw and the pressure re-
lief is now set.
Fruitland suggests this procedure and verication of your pres-
sure reliefs operation within your system are re-checked and or
set during your routine maintenance schedule for the tank and
truck.
*Fruitland Vacuum Relief - PART # VB
Remove the setting screw cover (1) - insert a at tip screwdriver into the incision and pry o
the cover carefully. Loosen the stop set nut (3) - hold rm the vacuum relief bell (2) - Turn the
bell clockwise - CW - to increase pressure and turn the bell counter clockwise - CCW - to re-
duce pressure in the vessel.
During this adjustment it is not necessary to hold the set nut stem (3) with a screwdriver.
When desired pressure in the vessel is achieved, tighten the stop set nut (3) - hold rm the
vacuum relief bell (2). Install the setting screw cover (1) - and the vacuum relief is now set.
To eliminate tampering with the adjusted setting of the vacuum relief - insert wire through
the screw cover (1) and then into bell (2) and connect wire with a permanent seal.
Fruitland suggests this procedure and verication of your pressure reliefs operation within
your system to be re-checked and or re-set during your routine maintenance schedule for the
tank and truck.

8Fruitland Manufacturing • Toll Free: 1-800-663-9003 • www.fruitlandmanufacturing.com
ATTENTION
All Fruitland Vacuum pumps should never run for a prolonged period
of time without air passing through the pump & system itself.
Incorporating vacuum & pressure relief valves is highly recommended
In addition to the incorporation of vacuum & pressure reliefs the outside of these valves,
vacuum pump housing, pump shroud and pumps cooling fan blades should, at all times be
kept clean of all debris to allow proper pump & system cooling.
Failure to allow air to be conveyed through your vacuum pump & system may result in severe
system damage that may cause severe injury, death, and void the pumps warranty.
SERVICE NOTE
USE AUTHENTIC FRUITLAND PARTS ONLY!
If you have any questions, or require further information on installing,
operating and or the maintenance of your vacuum pump contact:
1-800-663-9003 - [email protected] - [email protected]
*If you require these components, please contact your supplier or Fruitland Manufacturing
(They may not be included in the pump or package you acquired)

9
Fruitland Manufacturing • Toll Free: 1-800-663-9003 • www.fruitlandmanufacturing.com
RCF172 RCF344
1 Litre 18 hr 8 hr
1 Imp. Gal. 82 hr 36 hr
1 US Gal. 68 hr 30 hr
LUBRICATION & APPROVED OILS
Lubrication: If the suction temperature is >50°F (summer conditions), a SAE-40 non detergent
motor oil or an ISO 150 compressor oil can be used. If the suction temperature is <50°F (Winter
Conditions) a SAE-30 non detergent motor oil or an ISO 100 compressor oil is recommended.
Always check oil level before starting unit.
NEVER ALLOW OIL RESERVOIR TO
GET LOW!!!
Vacuum pumps dispose of and or consume oil during operation and
do not have a return within the system. All vacuum pumps will have
an oil sight glass, tube or dipstick. If a remote reservoir is used, verify that this
reservoir has oil. Always use the manufacturer’s recommended oil. The oil level
needs to be checked on a routine basis during the vacuum pumps operation.
All Pump Models
Oil Tank - Important! During routine cleaning & freezing weather, drain possible
condensation build-up in the bottom of the oil tank. Water can enter oil tank and be ingested
into the oil pump, this could cause the oil pump to freeze and damage the internal gears of the
oil pump. If you suspect water is present within the oil tank reservoir, drain and clean the oil
tank with diesel fuel.
Oil ConsumptionConsumption --approximateapproximate::

10 Fruitland Manufacturing • Toll Free: 1-800-663-9003 • www.fruitlandmanufacturing.com
Oils Approved for use in Fruitland Vacuum Pumps
OIL TYPE WINTER WEIGHT SUMMER WEIGHT
FRUITLAND® GREEN™ OIL (100% Biodegradable) SAME SAME
¹SHELL TURBO T OIL 32 68 or 100
¹ ISO COMPRESSOR OIL 100 150
MONOLEC COMPRESSOR OIL* SAME SAME
MOBIL SHC 525 (Synthesized Hydrocarbon) SAME SAME
¹ MOBIL DTE LIGHT OR HEAVY MEDIUM
ANDEROL 497 MEDIUM SAME SAME
¹ CHEVRON GST 32 68
¹ PENNZOIL PENNZBELL TO OIL 32 or 46 68
¹ TEXACO REGAL R & O OIL 32 68
¹ SAE NON DETERGENT OIL 10 or 20 30 or 40
SHELL ROTELLA 15W-40 MOTOR OIL SAME SAME
These oils have been approved for use in Fruitland Vacuum Pumps. Use of these oils will
maintain the vacuum pump warranty as well as extend the life of the vacuum pump and
ensure proper performance and lubrication.
When operated properly, Fruitland vacuum pumps will run cooler, use less oil
and provide much longer service than any other rotary vane vacuum pump.
*Monolec Compressor Oil is colored red and should not be confused with transmission uid.
¹ Recommended for the best performance and lubrication at all temperature levels.
Oils & Fluids That Are Not Approved For Use In
Fruitland Vacuum Pumps
OIL TYPE OIL TYPE OIL TYPE
BRAKE FLUID HYDRAULIC FLUID TRANSMISSION FLUID
DEF FLUID POWER STEERING USED OIL VEGETABLE
GEAR OIL FLUID SCENTED OIL USED OIL
WARNING
Always check oil level before starting vacuum pump, Fill if necessary.
Operating your Fruitland vacuum pump with the incorrect oil
can result in misuse of this product that may result in severe
injury, death, severe system damage, and or void the pump’s warranty.
Este manual sirve para los siguientes modelos
6
Tabla de contenidos
Otros manuales de Bomba de agua de Fruitland
Manuales populares de Bomba de agua de otras marcas

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guía de solución de problemas

DUROMAX
DUROMAX XP WX Series Manual de usuario

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manual de usuario

Franklin Electric
Franklin Electric IPS Manual de usuario

Xylem
Xylem e-1532 Series Manual de usuario

Milton Roy
Milton Roy PRIMEROYAL Manual de usuario