10
Soloclim
Technical specications
*4) Outdoor air temperature 35 °C, relative humidity 41%. Ambient temperature 27 °C; relative humidity 47%.
*5) Outdoor air temperature 7 °C; relative humidity 87%. Ambient temperature 20 °C; relative humidity 59%.
*6) Indoor sound pressure measured in semi-anechoic chamber at a distance of 2 m.
Max work conditions
Cooling temperature, (indoor/outdoor, Dry Bulb) ; minimum 18 °C/-5 °C, maximum 35 °C/43 °C
Heating temperature, (indoor/outdoor, Dry Bulb) ; minimum 5 °C/-10 °C, maximum 27 °C/24 °C
Energy classication according to the directive 626/2011
Energy eciency class cooling: A. (SC1DCI-MINI: A).
Energy eciency class heating: A.
Art. no Type Cooling
output*1
[kW]
Heat
output*1
[kW]
EER COP Voltage
[V]
Refrigerant
amount
[kg]
WxHxD
[mm]
Weight*2
[kg]
282044 SC17DCI-MINI 2,35 2,40 3,01 3,15 230V~ 0,14 (R290) 810x549x165 38
283421 SC21DCIN 2,64 2,64 3,29 3,31 230V~ 0,65 (R32) 1010x549x165 41
283422 SC23DCIN 3,10 3,05 3,25 3,28 230V~ 0,65 (R32) 1010x549x165 41
283423 SC23DCI1000N*33,10 ,00, 3,25 3,28 230V~ 0,65 (R32) 1010x549x165 41
SC17DCI-MINI SC21DCIN SC23DCIN SC23DCI1000N
Cooling*1
Max. cooling output Dual Power*4kW 2,35 2,64 3,10 3,10
Nominal cooling output*4kW 1,73 2,09 2,33 2,33
Min. cooling output*4kW 0,70 0,83 0,92 0,92
Dehumidication capacity l/24h 0,70 0,80 0,90 0,90
Total power consumption *4kW 0,57 0,64 0,72 0,72
Heating*1
Max. heat output Dual Power*5kW 2,40 2,64 3,05 3,95
Nominal heat output*5kW 1,71 2,08 2,31 2,31
Minimum heat output*5kW 0,75 0,71 0,79 0,79
Total power consumption*5kW 0,54 0,63 0,71 0,71
Max. breaking current A 3,90 4,10 4,60 8,50
Air ow at max fan speed in/out m³/h 360/430 380/460 400/480 400/480
Air ow at med fan speed in/out m³/h 300/360 310/380 320/390 350/390
Air ow at min fan speed in/out m³/h 240/320 260/330 270/340 270/340
Max/Min sound pressure*6dB(A) 39/27 39/26 41/27 41/27
*1) According to standard EN 14511
*2) Weight without refrigerant
*3) Equipped with an electric coil that provides an additional 900 W