Forma Scientific 707 Manual de usuario

Forma Scientific, Inc.
Millcreek Road, P.O. Box 649
Marietta, Ohio 45750
U.S.A. Telephone: (740) 373-4763
Telefax: (740) 373-4189
________________________________________
Models:
707, 771, 733 and 754
Non-CFC, Ultra-Low Temperature
Chest Freezers
3.0 and 6.7 cu. ft. capacity
Manual No. 7000707 Rev. 3
Read this Instruction Manual
Failure to read, understand and follow the instructions in this manual may result in
damage to the unit, injury to operating personnel and poor equipment performance.
CAUTION: All internal adjustments and maintenance must be performed
by qualified service personnel.
Refer to the serial tag on the
back cover of this manual

FormaModel 700 Series ____________________________________________________
ii
*Refer to listing of all model numbers on page ii.
*700 Series Freezers
707 6.7 cu ft 120V
771 6.7 cu ft 230V
733 3.0 cu ft 120V
754 3.0 cu ft 230V
The material in this manual is for information purposes only. The contents and the product it
describes are subject to change without notice. Forma Scientific, Inc. makes no representations or
warranties with respect to this manual. In no event shall Forma Scientific, Inc. be held liable for any
damages, direct or incidental, arising out of or related to the use of this manual.
MANUAL NO. 7000707
319279/FR-1402 6/21/00 Revised electrical schematics aks
2FR-1357 12/1/99 Updated per A. Thomas for IEC 1010 (CE listing) ccs
-- 18249/SI-7545 7/7/99 Added P/N 195518 & 195519 air filter kits to parts list ccp
118286/FR-1296 5/11/99 Updated schematics for 771/5477 ccp
-- -- 11/17/98 Added battery change note to Section 3.6 deg
--- FR-1223 6/8/98 Changed temp board heg
-- FR-1203 5/26/98 Added metric units to ref. drawing for IEC-1010
02/98 Original Manual deg
REV ECR/ECN DATE DESCRIPTION By

FormaModel 700 Series ______________________________________________Service
iv
Do You Need Information or Assistance on Forma
Products?
do, please contact us 8:00 a.m. to 7:00 p.m. (Eastern Time) at:
1-740-373-4763Direct
1-888-213-1790Toll Free, U.S. and Canada
1-740-373-4189FAX
http://www.forma.comInternet Worldwide Web Home Page
[email protected]mService E-Mail Address
If you
Our staff can provide information on pricing and giveyou quotations. We
can take your order and provide delivery information on major equipment items or make
arrangements to have your local sales representative contact you. Our products are listed on the
Internet and we can be contacted through our Internet home page.
Ourstaff can supply technical information about proper setup,
operation or troubleshooting of your equipment. We can fill your needs for spare or replacement
parts or provide you with on-site service. We can also provide you with a quotation on our
Extended Warranty for your Forma products.
Whatever Forma products you need or use, we will be happy to discuss your
applications. If you are experiencing technical problems, working together, we will help you
locate the problem and, chances are, correct it yourself...over the telephone without a service
call.
When more extensive service is necessary, we will assist you with direct factory trained
technicians or a qualified service organization for on-the-spot repair. If your service need is
covered by the warranty, we will arrange for the unit to be repaired at our expense and to your
satisfaction.
Regardless of your needs, our professional telephone technicians are available to assist
you Monday through Friday from 8:00 a.m. to 7:00 p.m. Eastern Time. Please contact us by
telephone or fax. If you wish to write, our mailing address is:
ThermoQuest
Forma Scientific Division
Millcreek Road, PO Box 649
Marietta, OH 45750
International customers please contact your local ThermoQuest, Forma Scientific
Division distributor.
Sales Support
Service Support

FormaModel 700 Series _______________________________________________Safety
v
General Safety Notes used in this Manual
Important operating and/or maintenance instructions. Read the accompanying text
carefully.
Ce symbole attire l’attention de l’utilisateur sur des instructions importantes de
fonctionnement et/ou d’entretien. Il peut être utilisé seul ou avec d’autres symboles de
sécurité. Lire attentivement le texte d’accompagnement.
Wichtige Betriebs- und/oder Wartungshinweise. Lesen Sie den nachfolgenden Text
sorgfältig.
Importante instruccions de operacion y/o mantenimiento. Lea el texto acompanante
cuidadosamente.
Potential electrical hazards. Only qualified persons should perform procedures
associated with this symbol.
Ce symbole attire l’attention de l’utilisateur sur des risques électriques potentiels.
Seules des personnes qualifiées doivent appliquer les instructions et les procédures
associées à ce symbole.
Gefahr von Stromschlägen. Nur qualifizierte Personen sollten die Tätigkeiten
ausführen, die mit diesem Symbol bezeichnet sind.
Potencial de riesgos electricos. Solo personas das capacitadadas deben ejecutar los
procedimientos asociadas con este simbulo.

FormaModel 700 Series _______________________________________________Safety
vi
Equipment being maintained or serviced must be turned off and locked off to prevent
possible injury.
Risques potentiels liés à l’énergie. L’équipement en entretien ou en maintenance doit
être éteint et mis sous clé pour éviter des blessures possibles.
Geräte, an denen Wartungs- oder Servicearbeiten durchgeführt werden, müssen
abgeschaltet und abgeschlossen werden, um Verletzungen zu vermeiden.
El equipo recibiendo servicio o mantenimiento debe ser apagado y segurado para
prevenir danos.
Hot surface(s) present which may cause burns to unprotected skin or to materials
which may be damaged by elevated temperatures
Présence de surface(s) chaude(s) pouvant causer des brûlures sur la peau non
protégée, ou sur des matières pouvant être endommagées par des températures
élevées.
Heiße Oberfläche(n) können ungeschützter Haut Verbrennungen zufügen oder
Schäden an Materialien verursachen, die nicht hitzebeständig sind.
Superficias calientes que pueden causar quemaduras a piel sin proteccion o a
materiales que pueden estar danados por elevadas temperaturas.
√√ Always use the proper protective equipment (clothing, gloves, goggles etc.).
√√ Always dissipate extreme cold or heat and wear protective clothing.
√√ Always follow good hygiene practices.
√√ Each individual is responsible for his or her own safety.

FormaModel 700 Series _____________________________________________Contents
vii
Table of Contents
Section 1 - Installation and Start-Up
1.1 Unloading and Moving the Freezer.......................................................1-1
1.2 Getting to Know Your Freezer .............................................................1-2
1.3 Environmental Conditions....................................................................1-5
1.4 Installing the Wall Bumpers.................................................................1-5
1.5 Location ...............................................................................................1-6
1.6 Connecting the Alarm Battery..............................................................1-6
1.7 Remote Alarm Contacts........................................................................1-7
1.8 Optional Recorder ................................................................................1-7
a. Connecting recorder battery...........................................................1-7
b. Installing the chart paper...............................................................1-7
1.9 Attaching the Power Cord ....................................................................1-8
1.10 Power Switch (mains disconnect).......................................................1-8
1.11 Electrical Requirements and Connection .............................................1-9
1.12 Factory Settings...................................................................................1-9
1.13 Start Up and Loading...........................................................................1-9
Section 2 - Operation
2.1 Changing the Control Temperature Set Point........................................2-1
2.2 Changing the Over Temperature Alarm Set Point.................................2-1
2.3 Alarms..................................................................................................2-2
2.4 Silencing the Over Temperature Alarm ................................................2-3
Section 3 - Calibration
3.1 Temperature Display Calibration..........................................................3-1
3.2 Optional Recorder Calibration..............................................................3-2
a. Changing the recorder range............................................................3-2
b. Calibrating the chart recorder..........................................................3-3

FormaModel 700 Series _____________________________________________Contents
viii
Section 4 - Routine Maintenance
4.1 Cleaning the Cabinet Exterior ..............................................................4-1
4.2 Cleaning the Air Filter..........................................................................4-1
4.3 Cleaning the Condenser........................................................................4-1
4.4 Defrosting the Chamber........................................................................4-2
4.5 Cleaning the Lid Gasket .......................................................................4-2
4.6 Replacing the Battery............................................................................4-3
4.7 Preparing the Unit for Storage...............................................................4-3
Section 5 - Service
5.1 Servicing the Refrigeration System ......................................................5-1
Section 6 - Specifications
Section 7 - Parts List
Section 8 - Refrigeration Drawings
Section 9 - Electrical Schematics
Section 10 - Warranty Information

FormaModel 700 Series ___________________________________Installation/Start-Up
1-1
Section 1 - Installation and Start-Up
1.1 Unloading and Moving the Freezer
To remove the freezer from the pallet, use the 7/16” wrench to remove all the bolts
securing the shipping bracket to the pallet. Remove the shipping bracket. Remove the ramp
boards from the pallet and place the slotted end over the ramp brackets on the pallet. The support
blocks on the ramps will be facing down. Before moving the freezer, make sure the casters are
unlocked and moving freely. Align the caster with the ramp boards. Use adequate personnel to
roll the freezer off the pallet.
If tipped more than 45°, allow the unit to set upright for
24 hours before start up.
The freezer can be easily pushed to the desired approved location that is described in
Section 1.5. When the freezer is in position, set the front caster brakes.
The freezer must not be moved with the product load inside.

FormaModel 700 Series____________________________________Installation/Start-Up
1-2
1.2 Getting to Know Your Freezer
LED display - Shows
actual chamber temperature
and indicates the control
temperature set point when the
Press-To-Set button is pressed.
Condenser Hot
indicator - Lights when the
thermostat on the condenser
reaches 40°C, indicating
typically a dirty air filter, a
clogged condenser, a fan
failure or high ambient
temperature.
Set Point Adjustment
Screw - Sets the control
temperature set point.
Normal/Standby
switch - Silences the audible alarm.
Low Battery indicator - Flashes when the battery needs to be replaced.
Over Temp indicator - Flashes when the chamber temperature rises above the
Over Temperature Alarm setting.
Voltage Compensation indicator - Indicates when the in-coming electrical
power is being automatically adjusted to ensure that the compressor operates within
specification.
Press-to-Set button - Press to display control temperature set point.
Figure 1-1, Control Panel
AA
B
C
D
E
F
H
G

FormaModel 700 Series____________________________________Installation/Start-Up
1-3
1 2
3
1 2
3
Figure 1-2 Figure 1-3
3.0 cu. ft. Chest Freezer 6.7 cu. ft. Chest Freezer
Figure 1-4
Chest Freezer Base, back view
Figure 1-5
Chamber Probe Assembly
Recorder
Probe
Probe
Cover
Performance Alarm
Monitor and
Temperature Probe
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Otros manuales de Congelador de Forma Scientific