Forcepoint S1104 Instrucciones de instalación

Sidewinder
Hardware Guide
Models S1104, S2008, S3008
Revision E

2
Table of contents
Preface...................................................................................................................................... 3
Find product documentation.......................................................................................................................... 3
1 Introducing the appliances................................................................................................................................. 4
Models and features...................................................................................................................................... 4
Supported software........................................................................................................................................ 6
Network ports and NICs................................................................................................................................ 6
Types of management ports..........................................................................................................................7
eUSB support................................................................................................................................................8
Regulatory information................................................................................................................................... 8
2 Configuring the management ports.................................................................................................................10
Configure a dedicated management port.................................................................................................... 10
Configure the Remote Management Module.............................................................................................. 10
3 Re-imaging an appliance................................................................................................................................. 12
Update the eUSB device............................................................................................................................. 12
Re-image the appliance using the eUSB device....................................................................................... 13
Download the USB image and write it to a USB drive............................................................................... 14
Re-image the appliance using a USB drive................................................................................................ 14
4 Diagnosing hardware problems......................................................................................................................16
Run hardware diagnostics.......................................................................................................................... 16
View the system event log.......................................................................................................................... 17
S1104 control panel indicator lights............................................................................................................ 18
S2008 and S3008 control panel indicator lights..........................................................................................19

Preface | 3
Preface
This guide provides the information you need to configure, use, and maintain your product.
Find product documentation
On the Forcepoint support website, you can find information about a released product, including product
documentation, technical articles, and more.
You can get additional information and support for your product on the Forcepoint support website at https://
support.forcepoint.com. There, you can access product documentation, Knowledge Base articles, downloads,
cases, and contact information.

Introducing the appliances | 4
Introducing the appliances
The features and capabilities of models S1104, S2008, and S3008 allow you to plan and configure an appliance.
Models and features
Forcepoint™ Sidewinder® models S1104, S2008, and S3008 include the following features.
Table 1: Model features
Model Network
ports
Dedicated
management port?
Remote Management
Module?
Integrated SSL
accelerator?
Rack
height
S1104 4 No No No 1U
S2008 8 Yes No No 1U
S3008 8 Yes Yes Yes 1U
Model S1104
This figure shows the attributes of model S1104.
Figure 1: Model S1104 front panel
Number Description
1 Power button
2 RS-232 serial port
3 VGA port
4 Network port 1-0
5 Network port 1-1
6 Network port 1-2
7 Network port 1-3
8 USB ports

Introducing the appliances | 5
Model S2008
This figure shows the attributes of model S2008.
Figure 2: Model S2008 front panel
Number Description
1 Network port 1-0
2 Network port 1-1
3 Network port 1-2
4 Network port 1-3
5 Network port 1-4
6 Network port 1-5
7 Network port 1-6
8 Network port 1-7
9 Dedicated management port
10 VGA port
11 USB ports
12 RS-232 serial port
13 Power button
14 USB port
Model S3008
This figure shows the attributes of model S3008.
Figure 3: Model S3008 front panel

Introducing the appliances | 6
Number Description
1 Network port 1-0
2 Network port 1-1
3 Network port 1-2
4 Network port 1-3
5 Network port 1-4
6 Network port 1-5
7 Network port 1-6
8 Network port 1-7
9 Remote Management Module port
10 Dedicated management port mgr1
11 VGA port
12 USB ports
13 RS-232 serial port
14 Power button
15 USB port
Supported software
Several Sidewinder software versions are supported.
Model S1104
•Version 7 — 7.0.1.02.HW02 rev. B and later
•Version 8 — 8.1.1 and later
Models S2008 and S3008
•Version 7 — 7.0.1.02.HW03 and later
•Version 8 — 8.1.1 and later
Network ports and NICs
Sidewinder models S1104, S2008, and S3008 have multiple 1 gigabit RJ45 copper network ports, which are
physically labeled. These port labels correspond to Sidewinder NIC (network interface card) names for software
version 8.1.1 and later.
In version 8.1.1 and later, software NIC names for network ports are derived from a combination of two factors:
• Ethernet port number (labeled on the network module)
• Network module bay number where the Ethernet port is installed (“1” is used for appliances that do not have
network module bays)
This information is combined to create the NIC name as follows:
<module bay number>-<Ethernet port number>

Introducing the appliances | 7
The following table shows the NIC names for version 8.1.1 and later.
Table 2: NIC names in version 8.1.1
Model Software NIC names
S1104 1-0 to 1-3
S2008 1-0 to 1-7
S3008 1-0 to 1-7
Types of management ports
There are two types of management ports: dedicated management ports and Remote Management Module
ports.
Dedicated management ports
Models S2008 and S3008 include a single 10/100/1000 RJ45 copper dedicated management port, which
provides additional network connection options for management traffic.
Note: Model S1104 does not include a dedicated management port.
Supported types of network traffic
Dedicated management ports can be used for several types of network traffic.
• Firewall administration, including:
• Sidewinder Admin Console
• Forcepoint Sidewinder
• Secure Shell
• Streaming log data to remote servers, including:
• Syslog server
• High Availability heartbeat
Note: Conventional network ports can also be used for these types of traffic.
Identifying the management port
For Sidewinder version 8.1.1 and later, the management port NIC is named mgr1.
Remote Management Module port
Model S3008 includes a single 10/100 RJ45 copper Remote Management Module port, which provides system
management features independent from the Sidewinder operating system.
The Remote Management Module port cannot be used by Sidewinder and the port does not appear in the list of
firewall interfaces.

Introducing the appliances | 8
Note: Models S1104 and S2008 do not include Remote Management Module ports.
Features
You can use the Remote Management Module web interface to perform several tasks.
• View system information
• View system health, including:
• Sensor readings
• Event log
• Control the appliance remotely using console redirection
• Turn the appliance on or off
eUSB support
Some S2008 or S3008 models contain an integrated eUSB device that allows you to re-image the appliance or
run hardware diagnostics without the use of external media.
To determine if your model includes the eUSB device, locate the appliance part number. The part number can be
found on your activation certificate, or printed on a label on the appliance cover.
Appliances with the following part numbers contain the eUSB device:
•S2008 — 610-1653-05 or higher
•S3008 — 610-1654-05 or higher
Related tasks
Update the eUSB device on page 12
You can use the eUSB Flashing Utility to update the versions available on the eUSB device.
Regulatory information
In compliance with Federal Communications Commission (FCC) regulations, this section provides information
about the appliance models and contact information.
Model information
The regulatory information applies to Sidewinder S1104, S2008, and S3008 models.
Table 3: Regulatory model information
Sidewinder model Regulatory model
S1104 S1104
S2008 S2008/S3008
S3008 S2008/S3008

Introducing the appliances | 9
Contact information
Use the following information to contact us.
Forcepoint LLC
10900-A Stonelake Blvd
Quarry Oaks 1, Ste 350
Austin TX 78759
USA
+1-800-723-1166

Configuring the management ports | 10
Configuring the management ports
You need to enable the dedicated management ports for models S2008 and S3008, and Remote Management
Module for model S3008 to manage network traffic.
Configure a dedicated management port
The dedicated management ports included with models S2008 and S3008 are disabled by default. To configure
and enable a dedicated management port, perform these steps.
1. Create a zone for the management network.
2. Configure the NIC that corresponds to the dedicated management port and assign it to the management
zone.
3. Create or modify access control rules to allow the appropriate management traffic.
Related concepts
Dedicated management ports on page 7
Models S2008 and S3008 include a single 10/100/1000 RJ45 copper dedicated management port, which
provides additional network connection options for management traffic.
Configure the Remote Management Module
The Remote Management Module included with model S3008 is disabled by default. Perform these tasks to
configure and use the Remote Management Module.
If the appliance is deployed in a production environment, schedule a maintenance interval to enable the Remote
Management Module.
Related concepts
Remote Management Module port on page 7
Model S3008 includes a single 10/100 RJ45 copper Remote Management Module port, which provides system
management features independent from the Sidewinder operating system.
Connect the Remote Management Module port
To use the Remote Management Module, connect the Remote Management Module port to a network.
CAUTION: We recommend connecting the Remote Management Module port to a dedicated
management network that meets the security needs of your organization.
Enable the Remote Management Module
You can configure and enable the Remote Management Module.
1. Enter the appliance BIOS menu.
1. Restart or turn on the appliance.
2. Press F2 to enter the BIOS menu.
3. Navigate to the Server Management tab.
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Hardware de red de Forcepoint
Manuales populares de Hardware de red de otras marcas

Matrix Switch Corporation
Matrix Switch Corporation MSC-HD161DEL Manual de usuario

B&B Electronics
B&B Electronics ZXT9-IO-222R2 Manual de usuario

Yudor
Yudor YDS-16 Manual de usuario

D-Link
D-Link ShareCenter DNS-320L Manual de usuario

Samsung
Samsung ES1642dc Instrucciones de uso

Honeywell Home
Honeywell Home LTEM-PV Instrucciones de montaje