3. TROUBLESHOOTING
The troubleshooting information provided inthe following chartwillhelpisolateand
identifycrimping problems.
TroubleshootingChart,PV™ReceptaclesHT-95
PROBLEM POSSIBLECAUSE CORRECTIVE ACTION
1. Bellmouth(s)isdeformed
orimproperlypositionedon
wirebarrel.
Terminalisnot properly
positioned incrimping
area.
Loosen thetwo2-56 setscrews
on the sideof theanvilholder
and reposition guide pinsuntil
properbellmouth(s)is
achieved.
2. Disconnect(box)portionof
terminalisbent down.
Terminalissticking inwire
barrelcrimper.
Tooling isbroken or
cracked.
Replacewirebarrelcrimperas
described inSection 2,para-
graph 2.
3. The sidesof the terminals
wirebarrelarescoredor
scratched.
Wirebarrelcrimperis
defective.
Replacewirebarrelcrimperas
described inSection 4,para-
graph 2.
4. Flashingsformed on the
bottomof the wirebarrelare
unequalorabnormal.
Anviliswornorbroken.
Replaceanvilasdescribedin
Section 4, paragraph 1.
5. Insulationbulgesbetween
wireand insulation barrels.
Wireisinsertedtoo farinto
terminal.
Position the endof the
insulation sothatitliesmidway
between the endsof the wire
barreland theinsulationbarrel.
6. Insulationbulgesaround
insulation barrel.
Wiresizeorinsulation
diameterisincorrect for
the terminalbeingused.
RefertoSection1, paragraph
4(specifications)forcorrect
insulation diameter
requirements.