Flomotion Systems 2001H Series Manual de usuario

2001H Series
Peristaltic Chemical Feed Pump


Installation and Operation Manual
2001H Series
Peristaltic Chemical Feed Pump
December 2019
Flomotion Systems, Inc.
3 N. Main St, Middleport, NY 14105
Toll ree: (800)909-3569 (U.S. & Canada)
Tel: (716)691-3941
ax: (716)691-1253
www.flomotionsystems.com


TAB E OF CONTENTS
1.0 - SYSTEM OVERVIEW.....................................................................................................................................................................4
1.1 SAFETY...............................................................................................................................................................................................4
1.2 WARRANTY..........................................................................................................................................................................................4
1.3 RECEI ING..........................................................................................................................................................................................5
1.4 CUSTOMER MODIFICATION...................................................................................................................................................................5
1.5 INFORMATION FOR RETURNING PUMPS .................................................................................................................................................5
2.0 – 2001H SERIES PUMP AND PUMPHEAD....................................................................................................................................6
2.1 TUBING, SPINDLE AND CO ER INSTALLATION.......................................................................................................................................7
2.2 MOUNTING PUMP ON GEARBOX, INSTALLATION OF COLLET..................................................................................................................8
2.3 PUMP MOUNTING AND COLLET INSTALLATION PROCEDURE...................................................................................................................9
2.4 TUBE AND ROLLER INSTALLATION......................................................................................................................................................10
2.5 TUBING & CONNECTIONS...................................................................................................................................................................16
3.0 – 2001H MOTOR & GEARBOX.....................................................................................................................................................18
3.1 MOTOR SPECIFICATIONS.....................................................................................................................................................................18
3.3 GEARHEAD SPECIFICATIONS...............................................................................................................................................................18
4.0 – 2001H DRIVE ONTROLLER....................................................................................................................................................19
4.1 OPERATION AND WIRING....................................................................................................................................................................19
4.2 PROGRAMMING .................................................................................................................................................................................19
4.3 MANUAL SPEED / AUTO SPEED / RESTART TOGGLE SWITCH................................................................................................................19
5.0 - 2001 SERIES TUBING RUPTURE DETE TOR........................................................................................................................20
RUPTURE DETECTOR SYSTEM O ER IEW.................................................................................................................................................20
5.1 ALARM CAUSES.................................................................................................................................................................................20
5.2 WHAT TO DO IN AN ALARM CONDITION................................................................................................................................................20
5.3 RESETTING THE ALARM......................................................................................................................................................................20
5.4 RESUMING SER ICE...........................................................................................................................................................................20
5.5 INTERFACING TO THE 2001H AC TECH SM ECTOR CONTROLLER................................................................................................21
5.6 CALIBRATION.....................................................................................................................................................................................21

1.0 - System Overview
The 2001H Series Chemical eed Pump consists of a controller, motor, gearbox and peristaltic pump.
Model 2001H
with pump-mounted controller
1.1 Safety
In the interests of safety, this pump and the tubing selected should only be used by competent, suitably trained
personnel after they have read and understood this manual, and considered any hazard involved. Any person
who is involved in the installation or maintenance of this equipment should be fully competent to carry out the
work.
Maintenance and repair should be performed by qualified personnel only. Make sure that no
voltage is applied while work is being carried out on the pump or motor. The motor must be
secured against accidental start up.
1.2 Warranty
lomotion Systems, Inc. warrants the 2001 Series pumps to be free of defects in material and workmanship for
a period of eighteen months from the date of sale to the user, or two years from the date of shipment, which
ever occurs first. An MC Series control, or any component contained therein, which under normal use becomes
defective within the stated warranty time period, shall be returned to lomotion Systems, Inc., freight prepaid,
for examination (contact lomotion Systems, Inc. for authorization prior to returning any product). lomotion
Systems, Inc. reserves the right to make the final determination as to the validity of a warranty claim, and sole
obligation is to repair or replace only components, which have been rendered defective due to faulty material
or workmanship. No warranty claim will be accepted for components which have been damaged due to
mishandling, improper installation, unauthorized repair and/or alteration of the product, operation in excess of
design specifications or other misuse, or improper maintenance. lomotion Systems, Inc. makes no warranty
that its products are compatible with any other equipment, or to any specific application, to which they may be
applied and shall not be held liable for any other consequential damage or injury arising from the use of its
products. This warranty is in lieu of all other warranties, expressed or implied. No other person, firm or
corporation is authorized to assume, for lomotion Systems, Inc., any other liability in connection with the
demonstration or sale of its products.
1.3 Receiving
Inspect all cartons for damage, which may have occurred during shipping. Carefully unpack equipment and
inspect thoroughly for damage or shortage. Report any damage to carrier and/or shortages to supplier. All

major components and connections should be examined for damage and tightness, with special attention given
to PC boards, plugs, knobs and switches.
1.4 Customer Modification
lomotion Systems, Inc., its sales representatives and distributors, welcome the opportunity to assist our
customers in applying our products. Many customizing options are available to aid in this function. lomotion
Systems, Inc. cannot assume responsibility for any modifications not authorized by its engineering department.
1.5 Information for Returning Pumps
Equipment that has been contaminated with, or exposed to, body fluids, toxic chemicals or any other
substance hazardous to health must be decontaminated before it is returned to lomotion Systems or its
distributor.
Please contact Flomotion Systems for a Return Authorization number and instructions for returning
the pump.

2.0 – 2001H Series Pump and Pumphead
The 2001H Series pumphead has two spring-loaded working rollers, which automatically compensate for minor
variations in tubing wall thickness, giving extended tube life.
IMPORT NT: The 2001 Series is equipped with a pump cover for safety and protection against
chemical spills. The cover must be installed whenever the pump is in use.
ROLLER ASSEMBLY
COLLET SCREW
5MM HEX WRENCH
7 NT.M 60 IN.OZ

2.1 Tubing, Roller Assembly and Cover Installation
! IMPORTANT: Disconnect pump controller from power supply BE ORE changing tubing!
Item No. Qty Part No. Description
1 1 n/a Pump Body
2 1 RA-01 Roller Assembly
3 1 100304B Cover
4 1 100324 Collet Screw
5 1 100305C Cover Gasket
6 4 100307C Cover Screw
7 1 varies Tubing
8 1 Varies with tubing selection* Tube Seal
Tubing is shown bent forward out of the pump housing to illustrate the correct tubing
and roller assembly position, prior to sliding the tubing and roller assembly into the
housing and over the collet.

2.2 Mounting Pump on Gearbox, Installation of Collet
Item No. Qty Part No. Description
1 1 na Pump Housing with Tube Seal & Tube
Seal Cover
2 1 100306 Collet
3 2 100312 Pump Mounting Screws
4 1 na Tubing
Otros manuales para 2001H Series
2
Tabla de contenidos
Otros manuales de Bomba de agua de Flomotion Systems
Manuales populares de Bomba de agua de otras marcas

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guía de solución de problemas

DUROMAX
DUROMAX XP WX Series Manual de usuario

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manual de usuario

Franklin Electric
Franklin Electric IPS Manual de usuario

Xylem
Xylem e-1532 Series Manual de usuario

Milton Roy
Milton Roy PRIMEROYAL Manual de usuario