Power
Alpha Technologies
®

FlexPoint FPR1207-F
Technical Manual
010-344-B1-001, Rev. A
Effective Date: February 2014
Copyright 2014
Alpha Technologies, Inc.
Photographs contained in this manual are for illustrative purposes only. These photographs may not match
your installation.
Alpha shall not be held liable for any damage or injury involving its enclosures, power supplies, generators,
batteries, or other hardware if used or operated in any manner or subject to any condition not consistent with
its intended purpose, or if installed or operated in an unapproved manner, or improperly maintained.
Operator is cautioned to review the drawings and illustrations contained in this manual before proceeding. If
there are questions regarding the safe operation of this powering system, please contact Alpha Technologies
or your nearest Alpha representative.
NOTE:
NOTE:
NOTE:
member of The Group
TM
To contact Alpha Technologies:
Visit www.alpha.com
or
For general product information and customer service (7 AM to 5 PM, Pacic Time), call
1-800-863-3930,
For complete technical support, call
1-800-863-3364
7 AM to 5 PM, Pacic Time or 24/7 emergency support
To report errors in this document, send email to:
3

Table of Contents
Safety Notes.......................................................................................................................... 6
1.0 Introduction................................................................................................................. 7
1.1 List of Terms..................................................................................................... 7
1.2 Theory of Operation......................................................................................... 7
1.3 System Features.............................................................................................. 8
1.4 Options............................................................................................................. 9
1.5 Items Included ................................................................................................. 9
2.0 Installation ................................................................................................................ 10
2.1 Installation and Connection............................................................................ 10
2.2 Battery Installation / Replacement Procedure................................................ 12
3.0 Operation ................................................................................................................. 13
3.1 Power On....................................................................................................... 13
3.0 Operation, continued ............................................................................................... 14
3.2 Audible Alarms and Visual Indicators............................................................. 14
3.3 Battery............................................................................................................ 14
3.4 Operational Modes......................................................................................... 15
3.4.1 Normal Mode ....................................................................................... 15
3.4.2 Back-Up Mode ................................................................................... 15
3.4.3 Emergency Use.................................................................................. 15
3.4.4 Charging Mode ..................................................................................... 15
4.0 Specications............................................................................................................ 16
010-344-B1-001 Rev. A (2/2014)
4

Figures and Tables
Fig. 1-1, Front View .................................................................................................... 8
Fig. 1-2, Rear View..................................................................................................... 8
Fig. 1-3, System Block Diagram ................................................................................. 8
Fig. 1-4, Items Included with each unit ....................................................................... 9
Fig. 2-1, Unit Dimensions ......................................................................................... 10
Fig. 2-2, FPR1207-F Output Cables and Connections..............................................11
Fig. 2-3, Function List (Inside Lid of Enclosure) ........................................................11
Fig. 2-4, Battery Terminals........................................................................................ 12
Fig. 2-5, Battery Compartment, FPR1207-F............................................................. 12
Fig. 2-6, Completed Installation................................................................................ 12
Fig. 3-1, Controls and Indicators............................................................................... 13
Table 3-1, Audible Alarm and Visual Indicators......................................................... 14
5
010-344-B1-001 Rev. A (2/2014)

Safety Notes
Review the drawings and illustrations contained in this manual before proceeding. If there are any questions
regarding the safe installation or operation of the system, contact Alpha Technologies or the nearest Alpha
representative. Save this document for future reference.
To reduce the risk of injury or death, and to ensure the continued safe operation of this product, the following
symbols have been placed throughout this manual. Where these symbols appear, use extra care and
attention.
A NOTE provides additional information to help complete a specic task or procedure.
NOTE:
A WARNING presents safety information to PREVENT INJURY OR DEATH to the
technician or user.
The use of CAUTION indicates safety information intended to PREVENT DAMAGE to material or
equipment.
CAUTION!
The use of ATTENTION indicates specic regulatory/code requirements that may affect the placement of
equipment and installation procedures.
ATTENTION:
WARNING!
010-344-B1-001 Rev. A (2/2014)
6

1.2 Theory of Operation
The FlexPoint 1207-F unit is an optical network terminal (ONT) power supply providing 7W of 12Vdc
primary and standby power.
A customer-provided 120Vac/230Vac, 50/60Hz power outlet provides primary power to the input of the
FlexPoint unit. The AC voltage is then converted to a usable 12Vdc output. The power supply is to be
installed near an AC power outlet.
Backup power and batteries are user friendly with features including, but not limited to, long life, ease of
replacement, purchase, installation and disposal. Power status is provided to the customer via audible
alarms and visual indicators.
The FlexPoint FPR1207-F power supply utilizes a Type-F Coaxial connector and cable for the output
connection to the SFU ONT.
Upon loss of AC service, the duration of standby power is determined by one 7.2Ah, or optional 8Ah
battery installed in the unit.
During a prolonged AC outage the unit monitors remaining battery capacity. When 25% of the battery
capacity remains, the 12Vdc supply to the ONT will be interrupted while the unit enters a sleep mode,
conserving the remaining capacity for emergency calls. Interruption of the 12Vdc supply to the ONT will
continue until the AC Mains is restored or the customer initiates the “Battery Emergency Use” mode by
pressing the Emergency Use button under the face plate.
FPR1207-F FlexPoint 1207-F Series Indoor 7W UPS with Type-F Coaxial connector
FTTH/FTTx Fiber To The Home/House/etc.
ONT Optical Network Terminal
ONT-PPS ONT Primary Power Supply
PFS Product Functional Specication
PON Passive Optical Network
PSTN Public Switched Telephone Network
SOC
State of Charge @25°C: 100% SOC i.e. fully charged battery @ 13.6V in oat mode after 24 hours (13.2V
open circuit)
0% SOC i.e. fully charged battery @ 10.5V during discharge (11.5V open circuit)
SFU:ONT Single Family Unit Optical Network Terminal; for this document ONT
UPS Uninterruptible Power Supply
1.0 Introduction
1.1 List of Terms
Terms used in this document:
The FlexPoint 1207-F power supply utilizes a Type-F Coaxial connector and cable for the output connection
to the ONT.
NOTE:
7
010-344-B1-001 Rev. A (2/2014)

1.0 Introduction, continued
1.3 System Features
• A robust power system which provides 7W of 12Vdc primary and standby power for FTTx
activity
• Easy customer replaceable hot swappable 7.2Ah battery
• Emergency battery reserve for greater E911 availability
• Battery management system engineered to provide optimum service life and runtime
• Local visual and audible status indicators
Fig. 1-1, Front View Fig. 1-2, Rear View
Fig. 1-3, System Block Diagram
ONT
FPR1207-F
12Vdc UPS
Up to 6’,
(1.8 meters)
Network
Area
Customer
Area
120Vac/230Vac
FlexPoint FPR1207-F
Coaxial cable with Type-F connector
FPR1207-F: Up to 5’ (~1.5 meters)
010-344-B1-001 Rev. A (2/2014)
8

1.5 Items Included
Verify the following items are included wth each unit.
Fig. 1-4, Items included with each unit
Optional Batteries
AX-STDBAT-7 Battery 7.2AH AGM, 1-year Warranty
AX-LONGBAT-7 Battery 7.2AH AGM, 3-year Warranty
AX-LONGBAT-8 Battery, Longlife, 8Ah, AGM 3-year Warranty
1.0 Introduction, continued
1.4 Options
The FlexPoint FPR1207-F supports three models of batteries:
1Quick Start Guide
FlexPoint FPR1207-F: Alpha P/N 010-344-B0
Bag with 2 cable ties
2
3
2
4
3
FlexPoint unit
4Line cord
1
9
010-344-B1-001 Rev. A (2/2014)

2.0 Installation
2.1 Installation and Connection
Observe wiring harness polarity. Improperly connecting these wires can result in non-operation of
the unit, cause equipment damage, and void the warranty.
CAUTION!
Mounting holes for #12
hardware or equivalent
“Keyhole” slots for
easy mounting
1
2
Center of Gravity
(with battery installed)
Fig. 2-1, Unit Dimensions (in/mm), FPR1207-F as viewed from back
1. Unpack and inspect the unit.
2. The unit is designed for use in a sheltered environment protected from rain and snow.
Its operating temperature range is 0°C to 40°C / 32°F to 104°F (ambient). Install the unit
near an AC outlet.
3. Remove battery compartment door by pressing tab and opening door. Remove the door
and set aside until the installation process is complete.
4. Determine the necessary cable length to provide appropriate service loops between the
unit, the ONT, and the outlet. Plug the line cord into the receptacle on the back of the unit
and secure with a wire tie. DO NOT plug the unit into an AC outlet until the last step of the
installation procedure.
5. Mount the unit to the wall with #12 fasteners or equivalent, using the keyholes for easy
mounting. For applications (with 7.2Ah battery only) with higher seismic requirements,
use the round holes in the back of the unit for direct fastening to a stud or other structural
feature.
The power supply cord is used as the main disconnect device. Verify the socket/outlet is located/
installed near the equipment and is easily accessible.
CAUTION!
7.8"
198mm
3.0"
76mm
2.5"
63.5mm
2.4"
61mm
3.0"
76mm
1.3"
33mm
8.7"
221mm
1
1
2
2
0.380"
9.7mm
.200"/5mm
0.250"
6.35mm
010-344-B1-001 Rev. A (2/2014)
10
Tabla de contenidos
Manuales populares de Unión Postal Universal de otras marcas

Pylontech
Pylontech Victron & Pylontech US5000 Manual de usuario

Tecnoware
Tecnoware EVO DSP PLUS MM 6.8 Manual de usuario

Mecer
Mecer ME-1000-WTU Manual de usuario

Mustek
Mustek PowerMust 530(B) Plus Manual de instalación y operación

Emerson
Emerson Liebert NXL series Manual de usuario

MAKELSAN
MAKELSAN BOXER SERIES Manual de usuario