FJDynamics PowerSec MP2000 Manual de usuario

PowerSec MP2000
User Manual
Thank you for purchasing the PowerSec MP2000 portable power station.
Toensure personal and property safety and proper use of the product, read this manual
carefully before operation and keep it for subsequentreference.
Charging Instructions
Before using the product, ensure that it is fully charged.

1
FJ Dynamics Technology Co., Ltd. All rights reserved.
Safety Instructions
Read the following instructions before use to ensure your safety. Improper use may cause fire,
property damages, or personal injuries.
Instructions for use:
1)
The charging power is up to 1,200 W. Use the provided AC charging cable for fast charging.
Plug the cable directly into an AC wall outlet and ensure that the output current is higher than
10 A. FJ Dynamics is not liable for any consequences caused by failure to follow the
instructions, including but not limited to charging with other AC charging cables.
2)
Do not place the product near a fire source. Keep away from direct sunlight.
3)
Do not charge, use, or store the product in a bathroom or in the rain or wet areas.
4)
Do not put the product in water. Water intrusion into the product may cause chemical reactions
of the battery, resulting in fire or explosion. Donot use swollen, leaking, or damaged batteries.
If your battery is abnormal, contact our technical support staff.
5)
Do not use the battery around strong electrostatic or electromagnetic fields. Otherwise, the
battery control board may malfunction during use, causing serious accidents.
6)
Do not disassemble or puncture the product in any way, as it may cause leakage, fire, or
explosion.
7)
Avoid collision. Do not use the product if a serious collision occurs to it.
8)
If the product falls into water during use, take it out immediately, put it in a safe area, and keep
a safe distance until it is completely dry. Do not use it again, and dispose of it properly
according to the "Disposal and recycling" section below.
9)
If the product catches fire, it is recommended to use the fire extinguishers in the following
order: water or water mist, sand, fire blanket, dry powder, and carbon dioxide fireextinguisher.
10)
Do not insert pins, wires, or other metal objects into the housing, sockets, or control board of
the product, as they may cause a short circuit.
11)
Do not place heavy objects on the product.
12)
Use and store the product in a clean and dry environment. If the surface of the plug or outlet
is dirty, clean it with a dry cloth. Otherwise, it may cause poor contact, energy loss, or
charging failure.
13)
Do not put the product in a microwave oven or pressurized container.

2
FJ Dynamics Technology Co., Ltd. All rights reserved.
Precautions for Charging
1)
Charge the product with a 200-240 V power supply.
2)
When using solar panels for charging, the open circuit voltage should notexceed 55 V.
3)
The product must be charged with the original charging cables according to the specifications.
FJ Dynamics is not liable for any damage caused by charging with third-party charging cables.
4)
During charging, do not place the product near flammable or combustible materials or leave
the product unattended.
5)
Do not charge the product immediately after a longtime heavy load discharge, because the
temperature of the product may be too high. Wait until it cools down to room temperature.
6)
The product must be charged at an ambient temperature of 0-40°C (32-104°F).
Storage and Transportation
1)
Keep the product out of children's reach. If a child accidentally swallows certain parts, seek
medical attention immediately.
2)
If a warning of low battery power appears, charge the battery before storage.
3)
Store the product in a dry environment and avoid contact with water.
4)
Ensure that no small metal objects fall on or around the product in storage.
5)
The battery power cannot be higher than 30% when it is transported byair.
Maintenance
1)
Do not store the product in an environment below -15°C or above 45°C.
2)
Longtime storage may shorten the battery service life.
3)
Fully charge and discharge the battery at least once every 3 months to preserve the service life.

3
FJ Dynamics Technology Co., Ltd. All rights reserved.
What's in the Box?
PowerSec MP2000 / solar charging cable / AC charging cable / 12 V car charging cable / user
manual.
PowerSec MP2000 Solar charging
cable AC charging
cable 12 V car
charging cable User manual
It is recommended to use DC 36 V 120 W/200 W/400 W/600 W solar panels.
PowerSec MP2000
The PowerSec MP2000 is a high-quality portable power station with a replaceable battery pack.
The convenient product can meet your emergency off-grid demands such as sudden power
failure caused by snowstorms or hurricanes, outdoor travel, outdoor operations, and RV power
supply. The product features a high output power of up to 2,000 W, fast charging, large capacity,
and long cycle life.
Technical Support
Users are provided with long-term technical support and upgrade services by FJ Dynamics
Technology Co., Ltd. from the date of purchase of this product.
Official website: https://www.fjdynamics.com/

4
FJ Dynamics Technology Co., Ltd. All rights reserved.
CONTENTS
1. Product Description ------------------------------------------------------------5
2. LCD Screen------------------------------------------------------------------------6
3. Charging ---------------------------------------------------------------------------8
4. Applicable Devices ----------------------------------------------------------- 10
5. Battery Replacement----------------------------------------------------------11
6. Operation Instructions------------------------------------------------------- 13
7. Specifications ------------------------------------------------------------------ 16
8. Troubleshooting --------------------------------------------------------------- 17
9. Maintenance and Warranty------------------------------------------------- 17

5
FJ Dynamics Technology Co., Ltd. All rights reserved.
⑦
⑧⑨
Product Description
1.
LCD screen
2.
12 V/4 A DC5525 outputport ×2
3.
12 V/8 A cigarette lighter outputport
4.
USB-C output port ×2
5.
USB-A output port ×4
6.
AC output port ×3
7.
Cooling fan
8.
Photovoltaic input port ×2
9.
AC input port
Note:
If the battery level is low, charge it before use.
①
②
④
⑤
⑥
③

6
FJ Dynamics Technology Co., Ltd. All rights reserved.
Buttons
A: Main power button
B: DC power button
C: USB power button
D: AC power button
Button A: main power switch. Press to turn on or off the product.
Button B: DC output switch. Before pressing this button to turn on DC output, ensure that the
product is powered on. Press this button to turn off the output when it is not in use.
Button C: USB output switch. Before pressing this button to turn on USB output, ensure that
the product is powered on. Press this button to turn off the output when it is not in use.
Note: The USB-C cables of different devices may support different protocols. If the USB-C
ports do not work, try to use an AC adapter for charging.
Button D: AC output switch. Before pressing this button to turn on AC output, ensure that the
product is powered on. Press this button to turn off the output when it is not in use.
LCD Screen
M N O P
I
H
H: Battery indicator
I: Input power
J: DC output
J K: AC output
L: USB output
M: AC charging cable indicator
N: Temperature alarm
O: Fan cooling
P: UPS
K L
POWERIN DCOUT
W
W
ACOUT USB OUT
% W
W
A
B
C
D

7
FJ Dynamics Technology Co., Ltd. All rights reserved.
Battery indicator: indicates the battery level with a bar graph and a percentage. The battery
level of 0-5% is shown with no bars, 6-20% with one bar, 21-40% with two bars, 41-60% with three
bars, 61-80% with four bars, and 81% and above with all five bars. It is recommended to fully
charge the product before using it for the first time. The higher remaining power, the more
accurate battery level percentage. Charge the product whenever the battery level is below 20%
to preserve the service life.
Note: When you plug the product into a power source like a solar panel or a wall outlet for the first
time, it may take a minute for the product to check and adjust its charging circuit before charging.
Input power: input power in watts during operation, or the fault code in case of error.
DC output: DC output power during operation, or the fault code in case of error.
AC output: AC output power during operation, or the fault code in case of error.
Note: This value varies with the power consumption of the connected devices, and this variation is
evident when the port initially outputs power to a connected device.
USB output: USB output power during operation, or the fault code in case of error.
AC charging cable indicator: displayed when an AC charging cable is plugged.
Temperature alarm: displayed when the inverter or the battery is overheated.
Fan cooling: displayed when the fan is running.
UPS: displayed when the product is charged from a wall outlet while providing power for devices
through its output ports.

8
FJ Dynamics Technology Co., Ltd. All rights reserved.
Fault codes:
Fault Code on
LCD Screen
Fault
Solution
E01
Battery overvoltage
Disconnect the charging cable and stop
charging.
E02
Battery undervoltage
Cut off the output and charge the
product.
E03
Inverter overheating
Cut off the output and wait for 1-2 hours
before using it again.
E04
Abnormal input voltage
Disconnect the AC charging cable or the
solar charging cable.
E05
Abnormal mains
frequency
Disconnect the charging cable.
E06
Abnormal output voltage
Cut off the output and check the
devices.
E07
AC output short circuit
Cut off the output and check the
devices.
E08
AC output overload
Cut off the output.
E09
Inverter fault
Contact customer service.
E16
AC charging overload
Cut off the output.
Note: In case of abnormal DC load, the system automatically turns off the output with no fault code
displayed. When this occurs, cut off the output, check the devices, and then try again. In case of
abnormal USB load, the USB output power changes to zero with no fault code displayed. When this
occurs, cut off the output, check the devices, and then try again.
Charging
AC wall charging
Charging the PowerSec MP2000 with the AC charging cable takes 1.8 to 2.5 hours. When the
battery level reaches 100% on the LCD screen, the battery is fully charged, and the charging
input will be turned off in several minutes.
AC outlet

9
FJ Dynamics Technology Co., Ltd. All rights reserved.
(Not included)
Note: When the product is being charged, the total power of the devices connected through
the AC output ports must not exceed 1,100W.Otherwise,the charging current will decrease.
Charging time
From solar panel
600 W 4-5 hours
Depending on solar conditions
From wall outlet
1.8-2.5 hours
Solar charging
The total open circuit voltage of solar panels connected in series-parallel must not exceed 55 V.
Place as many solar panels in direct sunlight as possible. The product can be charged through
12-55 V, 60 W/80 W/100 W/120 W/150 W/600 W solar panels. The charging time is dependent on
the sunlight intensity.
Caution:
1)
When charging the product through both PV input ports, ensure that same voltage is applied to the two ports.
2)
When charging the product with solar panels through both PV input ports, use solar panels of the same specifications for the two ports
to ensure that same voltage is applied to them.
Tabla de contenidos