General Operation of Control Panel........................................................................................28
Control Panel Front........................................................................................................................................ 28
LED Indication................................................................................................................................................ 29
Fire Alarm Controls........................................................................................................................................ 30
System Controls............................................................................................................................................. 31
User .................................................................................................................................................. 31
Supervisor......................................................................................................................................... 31
Engineer............................................................................................................................................ 31
Access Levels and Codes ................................................................................................................ 32
Access Level 0 (Normal): Controls Enabled LED off........................................................................ 32
Access Level 1 (User): Controls Enabled LED on............................................................................ 33
Access Level 2 (Supervisor): Controls Enabled LED flashing slowly............................................... 34
Access Level 3 (Engineer): Controls Enabled LED flashing quickly ................................................ 40
Alarm Confirmation Technology .............................................................................................45
Alarm Confirmation Delay.............................................................................................................................. 46
Selecting the Devices .................................................................................................................................... 46
Commissioning.........................................................................................................................47
Installation 1st Stage ...................................................................................................................................... 47
Installation 2nd Stage...................................................................................................................................... 47
Initialisation.................................................................................................................................................... 47
Commissioning .............................................................................................................................................. 48
Configuration Example .................................................................................................................................. 49
End User Training.....................................................................................................................49
Good Practice ...........................................................................................................................50
Number of Devices ........................................................................................................................................ 50
Label the Loop Ends...................................................................................................................................... 50
Note the Loop Readings................................................................................................................................ 50
Configuration Printout and Drawings............................................................................................................. 51
Initialisation...............................................................................................................................52
Normal Readings........................................................................................................................................... 52
Initialisation Process...................................................................................................................................... 52
Initialisation Faults ......................................................................................................................................... 54
Earth Faults.................................................................................................................................................... 56
General............................................................................................................................................. 56
General Fault Finding...............................................................................................................57
Common Faults.............................................................................................................................................. 57
Intermittent and Recurring Faults .................................................................................................................. 58
IMPORTANT NOTE....................................................................................................................................... 59
Advanced Connections............................................................................................................60
Monitored Relays........................................................................................................................................... 60