Fiberplex FOM-3841 Manual de usuario

USERMANUAL
4ChannelPOTSTelephoneFiberConverter
FOM‐3841/3842

WarningforYourProtection
1.Readtheseinstructions.
2.Keeptheseinstructions.
3.Heedallwarnings.
4.Followallinstructions.
5.Donotusethisapparatusnearwater.
6.Cleanonlywithadrycloth.
7.Donotblockanyoftheventilationopenings.Installinaccordancewiththemanufacturer’sinstructions.
8.Donotinstallnearanyheatsourcessuchasradiators,heatregisters,stoves,orotherapparatus(includingamplifiers)thatproduceheat.
9.Donotdefeatthesafetypurposeofthepolarizedorgrounding‐typeplug.Apolarizedplughastwobladeswithonewiderthantheother.A
groundingtypeplughastwobladesandathirdgroundingprong.Thewidebladeorthethirdprongisprovidedforyoursafety.Iftheprovidedplug
doesnotfitintoyouroutlet,consultanelectricianforreplacementoftheobsoleteoutlet.
10.Protectthepowercordfrombeingwalkedonorpinched,particularlyatplugs,conveniencereceptacles,andthepointwheretheyexitfromthe
apparatus.
11.Onlyuseattachments/accessoriesspecifiedbythemanufacturer.
12.Useonlywiththecart,stand,tripod,bracket,ortablespecifiedbythemanufacturer,orsoldwiththeapparatus.Whenacartisused,use
cautionwhenmovingthecart/apparatuscombinationtoavoidinjuryfromtip‐over.
13.Unplugthisapparatusduringlightningstormsorwhenunusedforlongperiodsoftime.
14.Referallservicingtoqualifiedservicepersonnel.Servicingisrequiredwhentheapparatushasbeendamagedinanyway,suchaspower‐supply
cordorplugisdamaged,liquidhasbeenspilledorobjectshavefallenintotheapparatus,theapparatushasbeenexposedtorainormoisture,does
notoperatenormally,orhasbeendropped.
Theapparatusshallnotbeexposedtodrippingorsplashing.Noobjectsfilledwithliquids,suchasvasesordrinkcups,shallbeplacedonthe
apparatus.
“WARNING:Toreducetheriskoffireorelectricshock,donotexposethisapparatustorainormoisture.”
GeneralInstallationInstructions
Pleaseconsiderthesegeneralinstructionsinadditiontoanyproduct‐specificinstructionsinthe“Installation”chapterofthismanual.
Unpacking
Checktheequipmentforanytransportdamage.Iftheunitismechanicallydamaged,ifliquidshavebeenspilledorifobjectshavefallenintothe
unit,itmustnotbeconnectedtotheACpoweroutlet,oritmustbeimmediatelydisconnectedbyunpluggingthepowercable.Repairmustonlybe
performedbytrainedpersonnelinaccordancewiththeapplicableregulations.
InstallationSite
Installtheunitinaplacewherethefollowingconditionsaremet:
Thetemperatureandtherelativehumidityoftheoperatingenvironmentmustbewithinthespecifiedlimitsduringoperationofthe
unit.Valuesspecifiedareapplicabletotheairinletsoftheunit.
Condensationmaynotbepresentduringoperation.Iftheunitisinstalledinalocationsubjecttolargevariationsofambient
temperature(e.g.inanOB‐van),appropriateprecautionsmustbetaken.
Unobstructedairflowisessentialforproperoperation.Ventilationopeningsoftheunitareafunctionalpartofthedesignandmust
notbeobstructedinanywayduringoperation(e.g.‐byobjectsplaceduponthem,placementoftheunitonasoftsurface,or
improperinstallationoftheunitwithinarackorpieceoffurniture).
Theunitmustnotbeundulyexposedtoexternalheatsources(directsunlight,spotlights).
AmbientTemperature
UnitsandsystemsbyFiberPlexaregenerallydesignedforanambienttemperaturerange(i.e.temperatureoftheincomingair)of+5...+40°C.
Whenrackmountingtheunits,thefollowingfactsmustbeconsidered:
Thepermissibleambienttemperaturerangeforoperationofthesemiconductorcomponentsis0°Cto+70°C(commercial
temperaturerangeforoperation).
Theairflowthroughtheinstallationmustallowexhaustairtoremaincoolerthan70°Catalltimes.
Averagetemperatureincreaseofthecoolingairshallbeabout20C°,allowingforanadditionalmaximum10C°increaseatthe
hottestcomponents.
Ifthecoolingfunctionoftheinstallationmustbemonitored(e.g.forfanfailureorilluminationwithspotlamps),theexhaustairtemperaturemust
bemeasureddirectlyabovethemodulesatseveralplaceswithintheenclosure.
GroundingandPowerSupply
Groundingofunitswithmainssupply(classIequipment)isperformedviatheprotectiveearth(PE)conductorintegratedinthreepinPhoenix™
connector.Unitswithbatteryoperation(<60V,classIIIequipment)mustbeearthedseparately.Groundingtheunitisoneofthemeasuresfor
protectionagainstelectricalshockhazard(dangerousbodycurrents).Hazardousvoltagemaynotonlybecausedbydefectivepowersupply
insulation,butmayalsobeintroducedbytheconnectedaudioorcontrolcables.
Thisequipmentmayrequiretheuseofadifferentlinecord,attachmentplug,orboth,dependingontheavailablepowersourceatinstallation.If
theattachmentplugneedstobechanged,referservicingtoqualifiedpersonnel.

Warranty,ServiceandTermsandConditionsofSale
ForinformationaboutWarrantyorServiceinformation,pleaseseeourpublished‘TermsandConditionsof
Sale’.Thisdocumentisavailableonfiberplex.comorcanbeobtainedbyrequestingitfrom
[email protected]orcalling301.604.0100.
Disposal
DisposalofPackingMaterials
Thepackingmaterialshavebeenselectedwithenvironmentalanddisposalissuesinmind.Allpackingmaterial
canberecycled.Recyclingpackingsavesrawmaterialsandreducesthevolumeofwaste.Ifyouneedto
disposeofthetransportpackingmaterials,recyclingisencouraged.
DisposalofUsedEquipment
Usedequipmentcontainsvaluablerawmaterialsaswellassubstancesthatmustbedisposedof
professionally.Pleasedisposeofusedequipmentviaanauthorizedspecialistdealerorviathepublicwaste
disposalsystem,ensuringanymaterialthatcanberecycledhasbeen.Pleasetakecarethatyourused
equipmentcannotbeabused.Afterhavingdisconnectedyourusedequipmentfromthemainssupply,make
surethatthemainsconnectorandthemainscablearemadeuseless.
Disclaimer
Theinformationinthisdocumenthasbeencarefullycheckedandisbelievedtobeaccurateatthetimeof
publication.However,noliabilityisassumedbyFiberPlexforinaccuracies,errors,oromissions,norforlossor
damageresultingeitherdirectlyorindirectlyfromuseoftheinformationcontainedherein.

Introduction
TheFOM‐3841andFOM‐3842providecompleteelectricalisolationforfourindependentchannelsof2‐wire
telephonecommunications.TheFOM‐3842supportsstandardanalogphones,STU‐III(securetelephoneunit)
phones,STE(securetelephoneequipment)phones,faxmachines,andmodemsandsupportsCallerID.
TheunitscanbeusedinareasofhighelectricalnoiseorinandoutofRFshieldedenclosures.Thefiberoptic
cableisnotsusceptibletointerferencecausedbyimpulsenoise,crosstalk,orEMI.Privacyofcommunications
isalsoenhancedbecausethefiberopticcabledoesnotradiateanyemissions.Inaddition,fiberopticcable
offersmuchlongertransmissiondistancesthantraditionaltelephonelinecordwiring.Multimodeopticson
theunitscanextendthedistanceto2km,whilesinglemodeopticscanfurtherextendthedistanceto20km.A
typicallinkconsistsofanFOM‐3841connectedtothePOTSlineandanFOM‐3842atthesubscriber’sphone
withaduplexfiberopticcablebetweenthem.
KeyFeatures
ChannelTelephonetoFiberModule
TypicalApplicationsInclude:
o StandardPOTSTelephones
o STU‐IIIandSTEPhones
o FaxMachines
o Modem
GettingStarted
InitialInspection
Immediatelyuponreceipt,inspecttheshippingcontainerfordamage.Thecontainershouldberetaineduntil
theshipmenthasbeencheckedforcompletenessandtheequipmenthasbeencheckedmechanicallyand
electrically.Iftheshipmentisincomplete,ifthereismechanicaldamage,oriftheunitfailstooperatenotify
FiberPlexandmaketheshippingmaterialsavailableforthecarrier'sinspection.

TypicalApplication

Features
RearIndicators/Connections
Figure1:FOM‐3841/3842Rear
1
1
1
2 2
3 3
4
6
5
6

ChassisMountingScrews(x2)–ThesecaptivefastenerssecuretheFOMcardinthechassis.Theheads
areknurledsothatnotoolisrequiredformounting/dismounting.
OpticsStatusLED–ThisLED,foreachposition,indicatesstatusasperthefollowingtable;
StatusLED–ThisLED,foreachposition,indicatesstatusasperthefollowingtable;
RJ‐11Exchange(FXO)Connectors–Connecttoexchangeattheseports.Seepinouttablebelow.
RJ‐11Instrument(FXS)Connectors–Connecttoinstrumentattheseports.Seepinouttablebelow.
RJ‐11Pinout
Pin Description
1
2
3 Ring(‐)
4 Tip(+)
5
6
OpticalFiberConnections–ThispositionmaybeapairofSTconnectors,LCconnectorsoranSFPslot,if
soordered.
OpticsStatusLED
Status Description
SteadyGreen Opticsinsyncateachendoflink
FlashingGreen LocalopticalRXisreceivingerrors
SteadyYellow RemoteopticalRXlossofsignalorsync
FlashingYellow LocalopticalRXsignalpresent,butnosync
FlashingOrange Cardtypemismatchatremoteend;thetwocardsarenotcompatible
SteadyRed NoopticalRXsignal
Off Cardfailure
PowerStatusLED
Status Description
SteadyGreen Cardpowersupplynormaloperation
SteadyRed Cardpowersupplyfailureorinover‐currentprotection
Off Cardfailureormainpowerfailure
1
2
3
4
6
5

FrontDisplays
Figure2FOM‐3841/3842FrontDisplay
TheseLEDsindicatesstatusasperthefollowingtable
POT S Exchange
Power
Optics
SW Option
Off Hook
Off Hook
Off Hook
Off Hook
Ringing
Ringing
Ringing
Ringing
CH 1
CH 2
CH 3
CH 4
FOM-3842
POTS Subscriber
Power
Optics
SW Option
Off Hook
Off Hook
Off Hook
Off Hook
Ringing
Ringing
Ringing
Ringing
Ring Down
CH 1
CH 2
CH 3
CH 4
DisplayLEDIndicators
Label Status Description
Power SteadyGreen Thepowersuppliesonthecardareoperatingproperly.
SteadyRed Thepowersuppliesonthecardarenotregulatingthecorrectvoltagesorthereisan
openfuseonthecard.Unplugthepowerfromthecardfor30secondsandthenplug
itinagainsothatthefuseonthecardhastimetoreset.IfthePowerledisstillredor
notaconstantgreen,replacethecard.
Off Cardfailureormainpowerfailure.
Optics SteadyGreen Opticsinsyncateachendoflink
FlashingGreen LocalopticalRXisreceivingerrors
SteadyYellow RemoteopticalRXlossofsignalorsync
FlashingYellow LocalopticalRXsignalpresent,butnosync
FlashingOrange Cardtypemismatchatremoteend;thetwocardsarenotcompatible
SteadyRed NoopticalRXsignal
Off Cardfailure
SWOption SteadyGreen NoFunction
OffHook Yellow Lineisoffhook
Off Lineisonhook
Ringing Yellow Lineisringing
Off Lineisidle
RingDown Yellow Fom‐3842ispairedwithanotherFOM‐3842for4‐channelringdown
Off NormalPOTSoperation

PowerRequirementsandMounting
FlexiblemountingallowstheFOM‐5400tobemountedinanyofanumberofFOM‐serieschassis.
ChassismountingusingRMC‐5000
Combinationsofupto16FiberPlexFOM‐seriescardsmaybeinstalledintoaRMC‐5000rackchassis.Aloaded
RMC‐5000isshownbelow;
Figure3FOMCardbeinginstalledintoanRMC‐5000
StandaloneusingSAC‐1‐AC
SingleFOM‐seriescardsmaybeinstalledintotheSAC‐1chassis,eitherdesk,wall,orrackmounted,depending
ontheaccessorybrackets(includedineverySAC‐1shipment)utilized.
Figure4FOMCardbeinginstalledinaSAC‐1‐AC

InsertingandRemovingSFPModules
IdentifytheLatchTypeoftheSFPModule
SFPModuleshavevariouslatchingmechanismstosecurethemintotheSFPCageofadevice.FiberPlex
ModulescansupportahostofmanufacturersandbrandsofSFPModulessotheusermayencounterany
numberofdifferentlatches.Someofthesearedescribedbelow.
BailClasp
ThebailclaspSFPmodulehasaclasp
thatyouusetoremoveorinstalltheSFP
module.
ActuatorButton
TheactuatorbuttonSFPmoduleincludesabuttonthatyou
pushinordertoremovetheSFPmodulefromaport.This
buttoncaneitherlift‘Up’orpress‘In’toreleasetheSFP
Moduledependingonthemanufacturer.
MylarTab
TheMylartabSFPmodulehasatabthat
youpulltoremovethemodulefroma
port.
SlideTab
TheslidetabSFPmodulehasatabunderneaththefrontofthe
SFPmodulethatyouusetodisengagethemodulefromaport.
HandlingWarnings
SFPModulesarestaticsensitive.Topreventdamagefromelectrostaticdischarge(ESD),itis
recommendedtoattachanESDpreventativewriststraptoyourwristandtoabaremetalsurfacewhen
youinstallorremoveanSFPModule.
DisconnectallopticalorcoppercablesfromSFPModulespriortoinstallingorremovingtheSFPModule.
Failuretodosocouldresultindamagetothecable,cableconnectorortheSFPModuleitself.Removing
andinsertinganSFPModulecanshortenitsusefullife,soyoushouldnotremoveandinsertSFPModules
anymoreoftenthanisabsolutelynecessary.
ProtectopticalSFPmodulesbyinsertingcleandustcoversintothemafterthecablesareremoved.Be
suretocleantheopticsurfacesofthefibercablesbeforeyouplugthembackintotheopticalportsof
anotherSFPmodule.AvoidgettingdustandothercontaminantsintotheopticalportsofyourSFP
modules,becausetheopticswillnotworkcorrectlywhenobstructedwithdust.
Este manual sirve para los siguientes modelos
1
Tabla de contenidos