Display for rotative transducer F20K-EN20M
Data:13/01/16 file: F20K+EN20M_ing.doc pg 4/7
Number of decimal digits +%
+%+%
+%
It is the number of decimal digits to visualize on the display, range allowed from 0 to 5.
Example 1: each turn of the hollow shaft will have a displacement on the machine of 50, set
0 =50 and +%=0.
Example 2: each turn of the hollow shaft will have a displacement of 12,345 and on display has to appear
12,3. The constant has to be set at 12,3450 and constant at 1.
Count direction %.+
%.+%.+
%.+
Set out the count direction of the display, range allowed 0 or 1.
Setting 0, the value on the display increases rotating the shaft in the counter clockwise.
Setting 1, the value on the display increases moving the sensor to the anticlockwise.
Keys opening mode //
////
//
This parameter programmes the functions linked to the keys.
The value to set is a number of three digits so each key corresponds to a digit; the digit on the right stands for
setting of key RESET, the digit in the middle stands for key while the last digit on the left stand for key
The Factory default is 101 or rather with the functions of absolute/relative quote (ABS/REL key) and reset
(RESET/ENTER key) activated.
The values allowed are the following:
VALUE KEY KEY KEY RESET/ENTER
0 Not open Not open Not open
1 Function ABS/REL Conversion mm/inch Reset
2 Not open Display in degrees Preset
3 Not open Not open Fast Preset
4 Not open Not open Change of origin 1,2,3,4,5
Reset: function of reset of quota, pressing on key RESET/ENTER the quota is zero-set .
Preset: function of preset of quota, pressing on key RESET/ENTER the quota on the display became the same
of the one set in parameter Preset. The setting of Preset value appears immediately after parameter
//
////
// (if chose value 2).
Fast Preset: the fast setting of the quota on the display, pressing on key RESET/ENTER appears Preset and
pressing still 2 times RESET/ENTER is possible to set the value directly (use keys and confirm with
RESET/ENTER). This function is useful when the quote on the display has often be corrected.
Origin change (quota correction for tool change): with this function 5 different origins (1,2,3,4,5 are
programmable and passes from an origin to the other wit key RESET/ENTER. Activating the function of origin
change on the display appear two small arrows and the indication of the selected origin happens with the
switching on of the origin indicators (see paragraph meaning of symbols ). After setting 4 in the first digit on
the right of //, will appear . and pressing 2 times RESET/ENTER has to be set the value to be
read in this position of sensor for origin 1, confirm with RESET/ENTER. It will appear . which is the value
to be read for origin 2 in the present position of sensor: set the correct value and confirm with RESET/ENTER.
It will appears . which is the value to be read for origin 3 in the present position of sensor: set the
correct value and confirm with RESET/ENTER.
For . and . to proceed as mentioned above.
It means ., ., ., ., . are references for the calibration, in a certain position of the
shaft, in 5 different origins.
Function ABS/REL:Enables the pass from absolute to relative value, pressing key zero-set temporary the
value to allow a relative shifting. On the display switches on indicator REL to indicate that the current quote is
relative to the zero-point just created. Pressing still key reappears the absolute value and on the display
switches on the indicator ABS.
Conversion mm/inch: Pressing key converts the measure from millimetre to inches and back with
indication of inch/mm on the display and a decimal number more then for millimetres. By choosing 5
decimals for millimetres the conversion in inches is not allowed.
Visualization in degrees: Pressing on key on the display appears Deg to indicate the visualization of
measure in degrees.