Fanmaster IAC-27 Manual de usuario

FA NM A ST E R
cooling heating ventilation extraction
INSTRUCTION MANUAL
MODEL: IAC-27, IAC-45, IAC-65
INDUSTRIAL PORTABLE AIR CONDITIONERS
TO PREVENT SERIOUS INJURY, READ & UNDERSTAND ALL WARNINGS &
INSTRUCTIONS BEFORE USE. PLEASE KEEP THIS DOCUMENT FOR YOUR RECORDS
FOR INDUSTRIAL USE ONLY

FOR YOUR INFORMATION
Thank you for purchasing a Fanmaster portable air condtioner. Please read this
instruction manual carefully before using this heater.
Disclaimer:
Fanmaster reserves the right to make alterations to specications, quantities,
dimensions, for production or other reasons, subsequent to publication.
While we believe the information is accurate and complete, we make no warranty
or representation for any particular purposes. The information is offered in good faith
and with the understanding that any use of the units or accessories in breach of the
directions and warnings in this document is at the sole discretion and risk of the user
Disposal Guidelines:
Do not dispose of this product with general household waste. This product must be
disposed according to the laws governing Waste Electrical and Electronic Equipment.
If required, contact your local authorities for information regarding the available
disposal facilities.

1. GENERAL SAFETY RULES & WARNINGS
• PLEASE READ INSTRUCTIONS CAREFULLY.
• PLACE INSTRUCTION MANUAL IN A SAFE PLACE FOR FUTURE REFERENCE. DO NOT ALLOW
ANYONE WHO HAS NOT READ THESE INSTRUCTIONS TO ASSEMBLE, ADJUST OR OPERATE THIS
APPLIANCE.
• IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION
MAY RESULT IN CAUSING PROPERTY DAMAGE, SERIOUS INJURY OR LOSS OF LIFE.
• FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS
APPLIANCE, CAN RESULT IN DEATH, SERIOUS INJURY AND PROPERTY LOSS OR DAMAGE FROM
HAZARDS OF FIRE, EXPLOSION, BURN, ASPHYXIATION, CARBON MONOXIDE POISONING,
AND/OR ELECTRICAL SHOCK.
• ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR
SERVICE THIS APPLIANCE. IF YOU NEED ASSISTANCE OR REQUIRE HEATER INFORMATION
SUCH AS AN INSTRUCTION MANUAL, LABELS, ETC. CONTACT FANMASTER.
• ADEQUATE VENTILATION IS REQUIRED. DO NOT USE IN ENCLOSED ENVIRONMENTS.
• DO NOT STORE OR USE GASOLINE, PETROL OR ANY OTHER FLAMMABLE OR COMBUSTIABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS APPLIANCE.
• FIRE, BURN, INHALATION, AND EXPLOSION HAZARD. KEEP SOLID COMBUSTIBLES, SUCH
AS BUILDING MATERIALS, PAPER OR CARDBOARD, A SAFE DISTANCE AWAY FROM THE
APPLIANCE AS RECOMMENDED BY THE INSTRUCTIONS. NEVER USE THE APPLIANCE IN SPACES
WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES, OR PRODUCTS SUCH
AS GASOLINE, SOLVENTS, PAINT THINNER, DUST PARTICLES OR UNKNOWN CHEMICALS
• NOT FOR DOMESTIC OR RECREATIONAL VEHICLE USE
• THE ELECTRICAL SYSTEM TO WHICH THE APPLIANCE IS CONNECTED MUST COMPLY WITH
LOCAL REGULATIONS. A RESIDUAL-CURRENT DEVICE (RCD) MUST BE INSTALLED.
• UNPLUG THE APPLIANCE BEFORE PERFORMING ANY MAINTENANCE OPERATIONS.
• ALWAYS CHECK THE POWER CABLE BEFORE USING THE APPLIANCE. IT MUST NOT BE BENT,
TAUT, STRETCHED, CRUSHED OR ANY WAY DAMAGED.
• IF THE POWER CORD AND/OR PLUG IS DAMAGED, IT MUST BE REPLACED BY FANMASTER, A
SERVICE AGENT OR A QUALIFIED PERSONS.
• THE EXHAUST OUTLET IS VERY HOT DURING OPERATION. DO NOT TOUCH! BURN DANGER.
• DO NOT LEAVE THE APPLIANCE UNATTENDED WHEN IN USE.
• NEVER USE THE APPLIANCE WITH WET HANDS OR WHEN EITHER THE APPLIANCE OR THE POWER
CABLE IS WET.
• CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY DO NOT PLAY WITH THE APPLIANCE.
• THE APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN) WITH
REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES, OR LOCK OF EXPERIENCE &
KNOWLEDGE.
FOR YOUR INFORMATION

2. PRODUCT DESCRIPTION & SPECIFICATIONS
PRODUCT DESCRIPTION
Industrial portable air conditioner, cooling only.
https://www.fanmaster.com.au/product/industrial-portable-air-conditioner-2-7kw-240v/
https://www.fanmaster.com.au/product/industrial-portable-air-conditioner-4-5kw-240v/
https://www.fanmaster.com.au/product/industrial-portable-air-conditioner-6-5kw-240v/
SPECIFICATIONS
MODEL IAC-27 IAC-45 IAC-65
Cooling Output* 2.7KW
9,200 BTU
4.5KW
15,300 BTU
6.5KW
22,000 BTU
Air Flow (L/s) 111 222 333
Rated Power 0.95KW 2.0KW 3.3KW
Voltage (V/Hz) AC220-240V/50 AC220-240V/50 AC220-240V/50
Current Rating (A) 4.2 9.0 1.5
Plug Connection 3 Pin 10amp 3 Pin 15amp 3 Pin 15amp
Refrigerant R410A R410A R410A
Refrigerant Charge 460 grams (+/- 10g) 800 grams (+/- 10g) 1050 grams (+/- 10g)
No. of Cool Air Duct 1 2 3
Cooloing Duct Dia (mm) 120 120 120
Exhaust Duct Dia (mm) 160 200 250
Fan Speed 2 2 2
Noise (dBa) 55 60 65
Condenstation Tank (L) 5 8 13
Net Weight (kg) N/G 42 / 47 70 / 75 94 / 150
Product Dimensions
(mm) (W)405x(D)430x(H)855 (W)520x(D)480x(H)1035 (W)630x(D)560x(H)1245
Packaged Dimensions
(mm) 1 (W)484 x (D)515 x (H)965 (W)570x(D)610x(H)1110 (W)720x(D)650x(H)1350
Packaged Dimensions
(mm) 1 -(W)260x(D)350x(H)370 (W)380x(D)280x(H)515
SAFETY DEVICES:
• Compressor Overheat & Overload Protection - power will be cut off if the
compressor overheats or there is high or low voltage .

3. GETTING TO KNOW YOUR APPLIANCE2. PRODUCT DESCRIPTION & SPECIFICATIONS
Cool Air
Duct Arm
Hot Exhaust Duct
Control Panel/
Swtiches
Filter Screen
Front Panel
Castors
Condensation
Tank
Handle

4. ASSEMBLY/INSTALLATION
ATTACHING THE COOL DUCT & ELBOW
• Elbow - attach elbow to the base plate (on the machine) by inserting the attach
point of the elbow into the base plate and rotate it anticlockwise. You will hear a
click.
• Cool Duct - insert the attach point to the top of the elbow and rotate it
anticlockwise.
Cool Air
Duct Arm
Indents
Attach Point
Attach Point
Indents
Base Plate
Top of Elbow
ATTACHING THE HOT EXHAUST DUCT
• Attach hot exhaust duct on to the heat vent on the machine.

4. OPERATING INSTRUCTIONS4. ASSEMBLY/INSTALLATION
TURN ON & OFF
• Rotate the selector switch to setting 1 or 2 , the compressor will turn on.
• To turn the appliance off, rotate the selector switch to “0”.
Always to turn the appliance off from the switch on the appliance before unplugging
it from the power source.
ADJUSTING THE COOL DUCT ARMS & EXHAUST DUCT
• Cool duct arms can rotate left or right to 360 degrees
• Cold duct arms can be moved up or down to 150 degrees
When adusting the cool duct arms, grip the elbow then make the adjustments.

4. OPERATING INSTRUCTIONS - CONTINUED
WATER TANK
• When the water tank is full, the appliance will stop operating. Turn selector switch
to “0”, remove water tank and empty.
OTHER
• When the appliance is running, both the lter screen and the cool duct arms shall
be 30cm or more away from the wall or other obstacles, and the hot exhaust
pipe shall be 80cm or more from the roof or obstacle.
• Position the appliance so it stands upright and is on a rm/at surface.
• It is prohibited to use it in rain, snow and other humid sites.
• Please do not place obstacle in front of the lter screen or air outlet of the cold
air pipe and the hot exhaust pipe. Please do not point the hot air from the hot
exhaust pipe to articles with poor heat resistance.

5. CLEANING, MAINTENANCE & STORAGE4. OPERATING INSTRUCTIONS - CONTINUED
• Before starting any maintenance task, shut down, unplug and let the appliance
cool down for at least 15 minutes.
• Do not attempt any electrical repair yourself. If the appliance needs service or
repair, contact a qualied person.
• When cleaning, make sure that water does not enter the unit.
• Do not open the enclosure to clean the inner parts. Do not spray water into the
appliance.
• Never use solvents, gasoline, toluene and similar aggressive chemicals to clean
the heater.
Regularly wipe the enclosure using a soft sponge or cloth. For very dirty parts, use a
sponge wetted with lukewarm water and a mild detergent, then dry using a clean
cloth.
Clean the lters (black) on a regular basis. Use a vacuum cleaner to remove the
dust and use clean water to wash it. Ensure the lter screens are dry before using the
appliance.
Check the power cord and plug for any damages, if damaged replace the cord or
plug immediately by a qualied person only.
STORAGE
• Remove any water from the condensation tank.
• Ensure the appliance is standing upright, do not place it horinzontally or upside
down.
• Ensure it is stored inside in a dry area.

6. WIRING DIAGRAM
IAC-27 IAC-45 & IAC-65
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Acondicionador de aire de Fanmaster

Fanmaster
Fanmaster OUBER PAC280-A Manual de usuario

Fanmaster
Fanmaster OUBER PAC280-A Manual de usuario

Fanmaster
Fanmaster OUBER PACISD Manual de usuario

Fanmaster
Fanmaster OUBER PACIMD Manual de usuario

Fanmaster
Fanmaster OUBER PACISD Manual de usuario

Fanmaster
Fanmaster Ouber PAC500 Manual de usuario

Fanmaster
Fanmaster Ouber PACISD-PA Manual de usuario