Evolution 2408 Manual de usuario

EN - Installation Guide
ES -Guía de instalación
www.evolvefan.com

READ AND SAVE THESE INSTRUCTIONS
CONTENTS
Product specifications 1
Before you start 5
Universal Mount Installation 8
Low Profile Mount Installation 18
Troubleshooting 29
Maintenance 30
Warranty 31

1
PRODUCT SPECIFICATIONS
Universal Mount – Integrated LED light
Product: Ceiling Fan
Models 2404 White motor / Wood blades finish
2405 Black motor / Light Wood blades finish
2406 White motor / White blades finish
2407 Black motor / Black blades finish
2411 Black motor / Dark Wood blades finish
Mounting Sloped or flat ceiling from 2.7 to 4.3m (9-14ft)
Quantity: 1 piece
Input Voltage 100-240 VAC, 1 phase, 50-60Hz
Maximum Weight 6.3 kilos (13.88Lbs)

PRODUCT SPECIFICATIONS
Universal Mount – No light version
Product: Ceiling Fan
Models 2408 White motor / white blades finish
2409 Black motor / Light Wood blades finish
2410 Black motor / Black blades finish
2412 Black motor / Dark Wood blades finish
Mounting Sloped or flat ceiling from 2.7 to 4.3m (9-14ft)
Quantity: 1 piece
Input Voltage 100-240 VAC, 1 phase, 50-60Hz
Maximum Weight 6.3 kilos (13.88Lbs)
2

PRODUCT SPECIFICATIONS
Low Profile Mount –Integrated LED light
Product: Ceiling Fan
Models 2432 White motor / wood blades finish
2433 Black motor / Light Wood blades finish
2434 White motor / white blades finish
2435 Black motor / Black blades finish
2437 Black motor / Dark Wood blades finish
Mounting Flat ceiling from 2.4 to 3m (8 - 10ft)
Quantity: 1 piece
Input Voltage 100-240 VAC, 1 phase, 50-60Hz
Maximum Weight 6.3 kilos (13.88Lbs)
3

4
PRODUCT SPECIFICATIONS
Low Profile Mount – No light version
Product: Ceiling Fan
Models 2429 White motor / white blades finish
2430 Black motor / Light Wood blades finish
2431 Black motor / Black blades finish
2436 Black motor / Dark Wood blades finish
Mounting Flat ceiling from 2.4 to 3m (8 - 10ft)
Quantity: 1 piece
Input Voltage 100-240 VAC, 1 phase, 50-60Hz
Maximum Weight 6.3 kilos (13.88Lbs)

5
BEFORE YOU START
WARNINGS
1. To reduce the risk of fire, electrical shock, or personal injury, mount fan directly from building
structure and/or an outlet box marked acceptable for fan support of 70 lbs. (31.8 kg) and use the
mounting screws provided with the outlet box.
2. To avoid possible electrical shock, before installing or servicing your fan, disconnect the power by
turning off the circuit breakers to the outlet box and associated wall switch location. If you cannot
lock the circuit breakers in the off position, securely fasten a prominent warning device, such as a
tag, to the service panel.
3. To reduce the risk of electric shock, this fan must be installed with an isolating wall control/switch.
4. To reduce the risk of personal injury, do not bend the blade brackets when installing the blade
brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
5. This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand the
hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall
not be made by children without supervision. It is recommended that children be supervised to
ensure that they are not using the appliance improperly.
Turn Off Power at Breaker
To avoid possible electrical shock, before installing your fan, disconnect the power
by turning off the circuit breakers to the outlet box associated with the wall switch
location.
WARNING

6
BEFORE YOU START
CAUTIONS
1. All wiring must be in accordance with national and local electrical codes ANSI/NFPA 70. If you are
unfamiliar with wiring, use a qualified electrician.
2. Use only Evolve Ceiling Fans replacement parts.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and if not installed and used in accordance with the instructions may
cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
•Reorient or relocate the receiving antenna.
•Increase the separation between the equipment and receiver.
•Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
•Consult the dealer or an experienced radio/TV technician for help.
Caution: modifications not approved by the party responsible for compliance could void user’s authority
to operate the equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
Do not use this fan with a dimmer switch
Ceiling
Height 2.8m (9’) 3m (10’) 3.4m
(11’) 3.6m (12’) 4m (13’) 4.3m (14’) 4.6m (15’)
Down-rod
Length
30cm
(12”)
45cm
(18”)
60cm
(24”)
91cm
(36”)
121cm
(48”)
152cm
(60”)
182cm
(72”)
Downrod length recommendation:
Outdoor Locations: Damp-rated fans installed in covered outdoor locations must have
fixed/permanent full overhead coverage extending at least 2 ft (0.6 m) out from the airfoil
tips on all sides.

7
BEFORE YOU START
CONGRATULATIONS!
You have chosen the best. Your new EVOLVE ceiling fan will provide you with many
years of comfort and satisfaction.
TIPS BEFORE STARTING!
1. Installation must be carried out by qualified wiring installer.
2. Turn of electrical source before installing.
3. Make sure the power supply range is correct.
4. The ceiling fan must be mounted to a minimum height ceiling of
9 feet or 2.3 meters from the floor.
5. Do not place any objects to the path of the blades.
6. Make sure that all screws and connections are tightly screwed
and secured.
7. When all electrical connections are done, store all wires neatly.
We are here to help!
This Instruction Manual is designed to make installation as simple as possible. We have added video
links to help you through the more technical sections. If you are unfamiliar or uncomfortable with wiring,
contact a qualified electrician. visit us at www.evolvefan.com.

8
UNIVERSAL MOUNT INSTALLATION
Integrated LED light. / No light version
For Low Profile Mount Installation, see page 18
Exploded View Drawing
Model Options:
Integrated LED light. Ceiling fan box will include: Light panel / lampshade.
No light version. Ceiling fan box will include: a lower cover.
Screw cover
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Idiomas: