Evolution Aqua Varipump 10000 Manual de usuario

INSTRUCTION MANUAL
Evolution Aqua Ltd. - Evolution House - Kellet Close - Wigan - Lancashire - United Kingdom - WN5 0LP
UK
English
VARIPUMP12209221MAN
PLEASE READ ALL OF THE INSTRUCTION MANUAL BEFORE
ATTEMPTING TO INSTALL OR OPERATE THE VARIPUMP.
In the unlikely event the pump is supplied with a plug, this can be cut off
and removed in the UK, as the mains supply cable should be wired into a
safe, compliant, outdoor electrical system, with an RCD cut-off.
Cutting the plug off will not invalidate the warranty.

WARNING: PLEASE READ THE FOLLOWING
SAFETY INFORMATION FIRST.
IMPORTANT SAFETY INFORMATION
- Please read the instruction manual carefully.
- The electrical installation is to be done by a qualified electrician,
in accordance with applicable electrical codes.
- WARNING: Always shut off electrical power before installation and /
or servicing this pump.
- A residual current device (RCD), also known as the residual current
circuit breaker (RCCB), with a tripping current not exceeding 30mA
must be installed in the supply circuit.
- A means of disconnection from the supply having a contact separation
of at least 3mm in all poles must be incorporated in the wiring.
- Check the pumps name plate for the following:
Voltage, Amp draw and Cycle.
- Do not use this power cord if there is any visible damage.
- Do not use this power cord in water or if the motor or electrical
receptacle is in contact with any standing water.
- This power cord should only be plugged into a properly installed RCD.
- Always test cycle a RCD to determine its condition before use.
- Improper installation can create electrical hazards which could result
in property damage, serious injury or death. Improper installation will
void the warranty.
- Do not submerse the controller in water.
- The pump should be operated when permissible temperature is
between 0˚C and 35˚C. The pump should never be operated
outside of these temperatures or damage may occur.
- Do not operate he pump without water.
- Young children must always be supervised near ponds.
Disposal Of Your Old Product
Your product is designed and manufactured with high quality material and components,
which can be recycled and reused. When this crossed-out wheeled bin symbol is attached
to a product, it means the product is covered by the European Directive 2002/96/EC.
Please contact your local authority about correct disposal for electrical and electronic
equipment. Our WEEE Registration Number is WEE/FE1471RR.
Please act according to your local rules and do not dispose of your old products with
your normal household waste. The correct disposal of your old product will help prevent
potential negative consequences for the environment and human health.

3
INTRODUCING THE EVOLUTION AQUA VARIPUMP
Congratulations on purchasing an Evolution Aqua Varipump.
Varipump by Evolution Aqua is a fully controllable pond pump, suitable for large ponds.
Output and energy consumption can be controlled at the push of a button allowing you to
set the flow rate to your needs whilst monitoring the operating wattage. The motor is quiet
and reliable, delivering consistent performance, while being very economical to run.
Available in three sizes, 10,000lph, 20,000lph and 30,000lph, Varipump is powerful
enough to run the largest of ponds and filters, and in the most demanding of situations.
It can be used as a submersible pond pump or it can be installed out of the pond,
drawing water from the pond and through your filtration system.

4
Varipump 10,000 Connectors & Washers
WHAT’S IN THE BOX?
Varipump 10,000
INSTALLATION ADVICE: Instead of using the fittings supplied we recommend purchasing
two 1½” Single Unions (Threaded Female To Plain Female), (EA Code: K82-76-55),
to connect the inlet and outlet of the Varipump 10,000 to 1½” Pressure Pipe.
Fittings and pressure pipe are available from Evolution Aqua stockists.
Varipump 10,000
(Strainer Basket & Base Plate)
Inlet & Outlet Connectors
To 40mm Pipe
Hosetail For
Inlet / Outlet
1 x Washer For Hosetail
2 x O-Rings For Connectors
45mm OD
33mm ID
x 3mm
36.5mm OD
x 2.65mm
36.5mm OD
x 2.65mm
Control
Box

5
Varipump 20,000 / 30,000 Connectors & Washers
WHAT’S IN THE BOX?
Varipump 20,000 / 30,000
Varipump 20,000 / 30,000
(Strainer Basket & Base Plate)
Inlet & Outlet Connectors
To 50mm Pipe
Hosetail For
Inlet / Outlet
3 x Washers For
Hosetail And Connectors
Control
Box
INSTALLATION ADVICE: Instead of using the fittings supplied we recommend purchasing
two 2” Single Unions (Threaded Female To Plain Female), (EA Code: K82-76-66),
to connect the inlet and outlet of the Varipump 20,000 / 30,000 to 2” Pressure Pipe.
Fittings and pressure pipe are available from Evolution Aqua stockists.
56mm OD
45mm ID
x 3mm

6
SPECIFICATIONS
INLET OUTLET
MAX.
FLOW
(LITRES
PER HOUR)
MAX.
FLOW
(GALLONS
PER HOUR)
MAX.
FLOW
(US GALLONS
PER HOUR)
MAX.
HEAD DIMENSIONS
Varipump
10000 1½” 1½” 10,000 2,200 2,642 3.1m
267mm (L)
122mm (W)
162mm (H)
Varipump
20000 2” 2” 20,000 4,400 5,283 5.5m
319mm (L)
142mm (W)
181mm (H)
Varipump
30000 2” 2” 30,000 6,600 7,925 5.5m
370mm (L)
155mm (W)
205mm (H)
PUMP CURVES

7
CONNECTION TO THE ELECTRICITY SUPPLY
Electrical installations must be done by a qualified electrician.
In the unlikely event the pump is supplied with a plug,
this can be cut off and removed, as it should be wired into a safe,
compliant, outdoor electrical system, with an RCD cut-off.
Cutting the plug off will not invalidate the warranty.
The power supply must meet the specifications on the product.
The cores in the supply cable are coloured in accordance with the following code:
Brown = Live. Blue = Neutral. Earth = Green/Yellow
(WHERE FITTED).
DO NOT use the supply cable to lift the pump as this may
cause damage.
WARNING - A Residual Current Device (RCD), also known as the Residual Current Circuit
Breaker (RCCB), with a tripping current not exceeding 30mA must be installed in the
supply circuit. A means of disconnection from the supply having a contact separation of at
least 3mm in all poles must be incorporated in the wiring.
Caution: Use in the area of the garden pond only if the installation complies with the
relevant wiring regulations. Please consult a qualified electrician.
Caution: Always disconnect all pond appliances from the mains supply before putting your
hands into the water.
All electrical installations and wiring must be adequately protected to prevent
any damage.
2 metres of electrical cable is supplied to connect the mains power to the control box.
10 metres of cable is provided to connect the control box to the pump.
This unit must be connected to permanent wiring. A switch with 3mm contact separation
must be provided in the fixed wiring to provide disconnection from the electricity supply.
Install this product where it will not come into contact with water or other liquids. Install
this product where it will be weather protected. Electrically ground this product. Failure to
follow these instructions can result in death, fire or electrical shock.
The control box is rated IPX4. It is therefore weather / rain-proof and can be kept outside,
it MUST NOT be submerged in water.
The pump is rated IPX8 and can be fully submerged in water.

8
VARIPUMP 10,000 TO 1½” PRESSURE PIPE
We recommend connecting Varipump 10,000 to 1½” Pressure Pipe.
To do this we recommend screwing a 1½” Single Union, Threaded Female To Plain Female
(EA Code: K82-76-55) onto the inlet and outlet of the Varipump. This also enables easy
access to the pump for maintenance when on a gravity fed set-up.
You can then glue 1½” Pressure Pipe (U15-050) directly into these connectors,
using Solvent Weld Adhesive (EA Code: S79-0-500).
VARIPUMP 20,000 AND 30,000 MODELS TO 2” PRESSURE PIPE
We recommend connecting Varipump 20,000 and 30,000 pumps to 2” Pressure Pipe.
To do this we recommend screwing a 2” Single Union, Threaded Female To Plain Female
(EA Code: K82-76-66) onto the inlet and outlet of the Varipump. This also enables easy
access to the pump for maintenance when on a gravity fed set-up.
You can then glue 2” Pressure Pipe (U15-063) directly into these connectors,
using Solvent Weld Adhesive (EA Code: S79-0-500).
If you want to connect the Varipump 20,000 or 30,000 to 1½” Pressure Pipe, follow steps
above and add a 2” to 1½” Plain Reducing Bush (EA Code: R81-063).
CONNECTING THE VARIPUMP TO PRESSURE PIPE
INLET
OUTLET
Pressure Pipe
Pressure Pipe
Single Union
Threaded Female
To Plain Female
Single Union Threaded
Female To Plain Female

9
CONNECTING VARIPUMP 10,000
TO FLEXIBLE HOSE
The stepped hosetail supplied allows connections
to 38mm (1½”), 32mm, 26mm Flexible Hose.
When fitting the hosetail, ensure the flat washer
provided is seated correctly inside the thread
before screwing to the outlet of the pump.
We advise using the largest connection therefore
the smaller sections of the hosetail must be cut off
to ensure sufficient water flow. Once the hosetails
have been trimmed, secure the flexible hose to
using a stainless steel hose clip (not provided).
CONNECTING VARIPUMP 20,000 & 30,000
TO FLEXIBLE HOSE
The stepped hosetail supplied allows connections
to 50mm (2”), 40mm, 32mm Flexible Hose.
When fitting the hosetail, ensure the flat washer
provided is seated correctly inside the thread
before screwing to the outlet of the pump.
We advise using the largest connection therefore
the smaller sections of the hosetail must be cut off
to ensure sufficient water flow. Once the hosetails
have been trimmed, secure the flexible hose to
using a stainless steel hose clip (not provided).
CONNECTING THE VARIPUMP TO FLEXIBLE HOSE

10
POND
Water Level Return to pond
UV
Alternative return via waterfall / blade
Alternative
return
Varipump
4” Pipe
Gravity fed filter installation example shown
INSTALLATION ADVICE - GRAVITY FED SET-UP
1. The pump suction line should be not smaller than 1½” (40mm imperial)
or 50mm true metric.
2. We recommend using Single Unions, Threaded Female To Plain Female,
to connect to Pressure Pipe (see page 8 for advice).
3. The suction line is to have as few bends or elbows as possible. There must not
be an air trap on the suction line.
4. Tighten the pump fittings only as much as is required to ensure a tight connection.
Excessive torque is unnecessary and may cause damage to the pump.
5. All wiring (electrical) work must be carried out by a qualified electrician and must
be installed in accordance to the local codes.
6. The motor must be earthed.
7. The weight of the plumbing and fittings is to be independently supported and not
carried by the pump.
8. The pump is not self-priming. Therefore, if the water level is below the pump,
a non-return valve must be installed below water level. The pump and inlet line
must be primed prior to start up. For non-flooded installations a check valve
(non-return valve) is recommended.
9. The controller must not be submerged in water.
10. Do not operate the pump without water.
Otros manuales para Varipump 10000
1
Este manual sirve para los siguientes modelos
2
Tabla de contenidos
Otros manuales de Bomba de agua de Evolution Aqua
Manuales populares de Bomba de agua de otras marcas

Sykes AmeriPumps
Sykes AmeriPumps GP100M Guía de solución de problemas

DUROMAX
DUROMAX XP WX Series Manual de usuario

BRINKMANN PUMPS
BRINKMANN PUMPS SBF550 Manual de usuario

Franklin Electric
Franklin Electric IPS Manual de usuario

Xylem
Xylem e-1532 Series Manual de usuario

Milton Roy
Milton Roy PRIMEROYAL Manual de usuario