EUCHNER ESM-F Series Guía del usuario

GB
More than safety.
System Manual
Modular Safety System
ESM-F

System Manual ESM-F
2
Contents
Correct use 3
Exclusion of liability and warranty 3
General safety instructions 3
Function 4
Status LEDs and pin assignment 5
Status LEDs and connections on the base units 5
Status LEDs and connections on the input modules 5
Status LEDs and connections on the output modules 5
Technical data 6
General technical data 6
Items supplied 14
Items supplied, base units 14
Items supplied, input modules 14
Items supplied, output modules 14
Accessories 14
Connection set 14
Mounting and replacing modules 15
Mounting 15
Replacing modules 16
Electrical connection 17
Starting behavior 18
Connecting safety inputs 19
Connecting safety contacts and feedback loop 22
Connecting base unit monitoring outputs 23
Connecting group outputs 23
Connecting expansion modules 24
Connecting input modules 24
Connecting output modules 26
Expanding time-delay output modules 27
Forming safety groups 28
Forming a group with the outputs GO1 and GO2 on an input module 28
Forming a group with the outputs GO1 and GO2 on a base unit 29
Response times of the ESM-F system 29
Setup 30
Trouble shooting 31
Status table 31
Inspection and service 34
Service 34
Declaration of conformity 35

System Manual ESM-F
3
Correct use
The base unit ESM-F-B... is used to evaluate safety-related signals in safety circuits
according to EN 60204-1. With this unit safety category 4 according to EN 954-1
can be achieved. The base unit can only be expanded using expansion devices in
the modular safety system ESM-F from EUCHNER. The device is not allowed to be
opened, tampered with, or modified. The permissible operating parameters are
to be observed during operation (see section “Technical data”).
Before the safety module is used, a risk assessment must be performed on the
machine in accordance with:
EN 954-1, Safety of machinery. Safety related parts of control systems. Gene-
ral principles for design, Annex B
EN 1050, Safety of machinery. Principles for risk assessment
IEC 62061, Safety of machinery - Functional safety of safety-related electrical,
electronic and programmable electronic control systems
Correct use includes compliance with the relevant requirements for installation
and operation, particularly
EN 60204-1, Safety of machinery. Electrical equipment of machines. General
requirements
Exclusion of liability and warranty
In case of failure to comply with the conditions for correct use stated above, or
if the safety instructions are not followed, or if any servicing is not performed as
required, liability will be excluded and the warranty void.
General safety instructions
The device is only allowed to be installed and placed in operation by authorized
personnel
who are familiar with the correct handling of safety components,
who are familiar with the applicable regulations on health and safety
and who have read and understood the operating instructions and the system
manual.
The safety function of the system while the machine is in operation can no longer
be ensured if the device is connected incorrectly or used incorrectly. Fatal injuries
may result.
Important!
Prior to use read the operating instructions and the system manual, and keep
these in a safe place. Ensure the operating instructions and the system manual
are always available during mounting, setup and servicing. EUCHNER cannot
provide any warranty in relation to the readability of the CD for the storage period
required. For this reason you should also archive a printed copy of the system
manual. If you should lose the operating instructions or the system manual, you
can download these documents from www.EUCHNER.de.

System Manual ESM-F
4
Function
The modules in the ESM-F system are used for the evaluation of the safety com-
ponents connected and the safe interruption of a safety circuit.
The base unit ESM-F-B... is part of the ESM-F system from EUCHNER. The ESM-F
system comprises at least one base unit.
The base unit has several inputs for the connection of safety components. The
safety contacts are switched as a function of the input signals. Subsequent parts
of the safety circuit can be monitored using a feedback loop.
Different device states can be signaled using monitoring outputs.
The base unit can be expanded with additional inputs and outputs using expansion
modules. The individual modules are connected together using a special connector
system. Power is supplied and safety signals are sent via the connector system.
If one of the safety components (e.g. an emergency stop) is actuated, the base
unit opens its contacts immediately. If additional output modules are used, these
also receive a signal to open their contacts. The system is designed such that
failures will not result in the loss of the safety function. The occurrence of failures
is detected by cyclic self-monitoring at the latest on the next demand to close
the safety contacts (e.g. on starting). The system can be started either manually
using a start button or automatically using a jumper. Safety groups with varying
safety levels can be formed using appropriate configurations (see section Forming
safety groups).

System Manual ESM-F
5
Status LEDs and pin assignment
All modules in the ESM-F system have status LEDs for the important module sta-
tes. The significance of the individual LED states is given in the section Trouble
shooting.
Status LEDs and connections on the base units
23
13
SI SA OV
SO
33 A1
14 24
Y2
Y1OY
O14
34 A2
ESM-F Basic
Pwr
In1 1 2
In2 1 2
In B G
Rx Tx
OG
OI
S23 S21 S22 S24
O2
O1
GO2 GI2
S13
S14
S12S11
GO1 GI1
Out 1
Out 2
Feedb
Out B
Status LEDs and connections on the input modules
ESM-F Input
Pwr
In1 1 2
In2 1 2
Rx Tx
O2
O1 GO2
GO1
S14
S12
S23
S24
S22S21
S13 S11
ESM-F Input
Pwr
In1 1 2
In2 1 2
In3 1 2
Rx Tx
O3
S33 S31 S32 S34
O2
O1
S14
S12
S23
S24
S22S21
S13 S11
Status LEDs and connections on the output modules
ESM-F Output
44
34
24
14
43
33
Y1
Y2
13 23
Pwr
Out 1
Out 2
Feedb
ESM-F Output
32
44
24
14
31
43
Y1
Y2
13 23
Pwr
Out 1
Out 2
Feedb
ESM-F Output
48
38
28
18
47
37
Y1
O17
Y2
17 27
Out 1 2
Pwr
Feedb
t
ESM-F Output
48
38
28
18
47
37
Y1
O17
Y2
17 27
Out 1 2
Pwr
Feedb
ESM-F-BSN-2C2O2
ESM-F-BMN-2C2O2
ESM-F-OSN-O3M1
ESM-F-OSN-O4 ESM-F-OT05NO4 ESM-F-OTNO4
ESM-F-I3I-3C2
ESM-F-ISI-6C1
ESM-F-IMI-3C2
ESM-F-ILI-3C2
ESM-F-ISI-2C2

System Manual ESM-F
6
Technical data
General technical data
Parameter Value Unit
Housing material Polyamide PA6.6
Dimensions ESM-F-B.. ESM-F-I.. ESM-F-O..
114 x 99 x 45 114 x 99 x 22.5 114 x 99 x 22.5 mm
Weight Approx. 0.26 Approx. 0.13 Approx. 0.18 kg
Connection type Plug-in connection terminals
Terminals 0.14 … 2.5 mm²
Ambient temperature
at UB= 24 V DC -15 ... +55 °C
Degree of protection to EN IEC 60529
IP 20
Degree of contamination
2
Mounting Expansion connector on DIN rail 35 mm
according to DIN EN 50022-35
Life Mechanical 1 x 107operating cycles
Electrical 1 x 105operating cycles
Connection data, base units ESM-F-B...
Parameter Value Unit
Operating voltage 24 ± 10% 1) V DC
Reverse polarity protection Yes
Power consumption Approx. 3.5 VA
Control voltage
at start button 18.6 … 26 V DC
Control cable length max.
(cross-section 0.75 mm²) 1000 m
Current consumption, max.
140without monitoring outputs mA
with monitoring outputs 320
External contact fuses
(safety circuit)
according to EN IEC 60269-1
10 AgG (T6A / F8A)
Rated impulse withstand voltage 2.5 kV
Leakage path and air gap acc. to
DIN VDE 0110-1:1997-04 4 kV
Cumulative therm. current for all
contacts 10 A
Safety contacts
Switching current, min., at 24 V DC
20 mA
Maximum switching voltage 50 V DC
250 V AC
Utilization category according to UeIeSIe
EN IEC 60947-5-1 AC-12 250 V 8 A
10 A
AC-15 250V 3 A
DC-12 50 V 8 A
DC-13 24 V 3 A
LEDs 13, diagnostics and status
Monitoring outputs (semiconductor)
Short circuit-proof Yes
Continuous current max. 30 mA
Output voltage 24 V DC
Inputs
Circuit ESM-F-BSN… 2 inputs, NC contact/NC contact, 2-channel
with short-circuit monitoring and earth fault monitoring
ESM-F-BMN… 2 inputs, NC contact/NO contact, 2-channel
with short-circuit monitoring and earth fault monitoring
1) All the electrical connections must either be isolated from the mains supply by a safety transformer according to EN IEC 61558-
2-6 with limited output voltage in the event of a fault, or by other equivalent isolation measures.
Ue= Switching voltage Ie= Maximum switching current per contact
SIe=
Maximum switching current per all safety contacts
(cumulative current)

System Manual ESM-F
7
Dimension drawing
Suitable for 35 mm DIN rail
according to DIN EN 50022-35
99
45 114
23
13
SI SA OV
SO
33 A1
14 24
Y2
Y1OY
O14
34 A2
ESM-F Basic
Pwr
In1 1 2
In2 1 2
In B G
Rx Tx
OG
OI
S23 S21 S22 S24
O2
O1
GO2 GI2
S13
S14
S12S11
GO1 GI1
Out 1
Out 2
Feedb
Out B
Block diagram ESM-F-B...
2313
24
14
Inputs
K2
K1
33
34
S23 S24
Y1 Y2
SO SI SA
O1 O2 OI OG O14 OY
Monitoring outputs
GI1 GI2
A1 A2
-
-
-
-
GO1
0V GO2
Group signal
Expansion connector
S11 S12 S13 S14 S21 S22
Expansion connector
Power
supply
Start function Input circuit 1 Input circuit 2
Feedback
loop

System Manual ESM-F
8
Connection data, input modules ESM-F-I
Parameter Value Unit
Operating voltage 24 ± 10% 1) V DC
Reverse polarity protection Yes
Power consumption Approx. 4.2 VA
Control cable length max.
(cross-section 0.75 mm²) 1000 m
Current consumption, max.
100
without monitoring outputs
mA
with monitoring outputs 160 (ESM-F-ISI-2C2)
190 (ESM-F-I3I-3C2, ESM-F-ISI-6C1,
ESM-F-IMI-3C2, ESM-F-ILI-3C2)
LEDs 9, diagnostics and status
Monitoring outputs (semicon-
ductor)
Short circuit-proof Yes
Continuous current max. per
output 30 mA
Output voltage 24 V DC
Inputs
Circuit ESM-F-I3I-3C2 3 inputs, NC contact/NC contact, 2-channel
with short-circuit monitoring and earth fault monitoring
ESM-F-ILI-3C2 3 inputs, NC contact/NC contact, 2-channel
without short-circuit monitoring and earth fault monitoring
ESM-F-ISI-2C2
2 inputs, NC contact/NC contact, 2-channel
with short-circuit monitoring and earth fault monitoring
outputs for forming a group
ESM-F-ISI-6C1 6 inputs, NC contact/NC contact, 1-channel
with short-circuit monitoring and earth fault monitoring
ESM-F-IMI-3C2
3 inputs, NC contact/NO contact, 2-channel
with short-circuit monitoring and earth fault monitoring
for the connection of safety switches
with NO contact/NC contact combination (e.g. CMS from
EUCHNER)
1) Supplied via expansion connector

System Manual ESM-F
9
Dimension drawing
99
22,5 114
ESM-F Input
Pwr
In1 1 2
In2 1 2
Rx Tx
GO2GO1
O2
O1
S14
S12
S23
S24
S22S21
S13 S11
99
22,5 114
ESM-F Input
Pwr
In1 1 2
In2 1 2
In3 1 2
Rx Tx
O3
S33 S31 S32 S34
O2
O1
S14
S12
S23
S24
S22S21
S13 S11
Block diagram ESM-ISI-2C2
S14 S21
Inputs
S22 S23 S24
GO1
Group
signal
S11
S12
S13
O1 O2
Monitoring
outputs
Input circuit 1 Input circuit 2
Expansion connector
Expansion connector
GO2
Block diagram ESM-I3I-3C2, ESM-F-IMI-3C2 and ESM-F-ILI-3C2
S14 S21
Inputs
S22 S23 S24 S31 S32
S11
S12
S13
O1 O3
O2
Monitoring
outputs
S33 S34
Input circuit 1 Input circuit 3Input circuit 2
Expansion connector
Expansion connector
Block diagram ESM-I..-6C1
S14 S21
Inputs
S22 S23 S24 S31 S32
S11
S12
S13
O1 O3
O2
Monitoring
outputs
S33 S34
Input circuit 1 Input circuit 2 Input circuit 3 Input circuit 4 Input circuit 5 Input circuit 6
Expansion connector
Expansion connector
Suitable for 35 mm DIN rail
according to DIN EN 50022-35

System Manual ESM-F
10
Connection data, output modules ESM-F-O...
Parameter Value Unit
Operating voltage 24 ± 10% 1) V DC
Reverse polarity protection Yes
Power consumption Approx. 2.4 VA
Current consumption, max. 100 mA
External contact fuses
(safety circuit)
according to EN IEC 60269-1
10 AgG (T6A / F8A)
Rated impulse withstand voltage 2,5 kV
Leakage path and air gap acc. to
DIN VDE 0110-1:1997-04 4 kV
Cumulative therm. current for all
contacts 10 A
Safety contacts
Switching current, min.,
at 24 V DC 20 mA
Maximum switching voltage 50 V DC
250 V AC
Utilization category according to UeIeSIe
EN IEC 60947-5-1 AC-12 250 V 8 A
10 A
AC-15 250 V 3 A
DC-12 50 V 8 A
DC-13 24 V 3 A
LEDs 4, diagnostics and status
Auxillary contact
(on ESM-F-OSN-O3M1)
Switching current, min.,
at 24 V DC 20 mA
Maximum switching voltage 50 V DC
250 V AC
Utilization category according to UeIe
EN IEC 60947-5-1 AC-12 250 V 8 A
AC-15 250 V 3 A
DC-12 50 V 8 A
DC-13 24 V 3 A
1) Power supplied via expansion connector
Ue= Switching voltage Ie= Maximum switching current per contact
SIe=
Maximum switching current per all safety contacts
(cumulative current)
Este manual sirve para los siguientes modelos
11
Tabla de contenidos
Manuales populares de Electricidad industrial de otras marcas

S&C
S&C Vista SD Manual de usuario

Murata
Murata GRM0335C2A7R3CA01 Series Manual de usuario

Siemens
Siemens 3VA9988-0BM10 Manual de usuario

Siemens
Siemens SITRANS LVS100 Manual de usuario

Murata
Murata GRM32ER60G227ME05 Series Manual de usuario

Siemens
Siemens SENTRON SUPERSWITCH 3KL82 Series Manual de usuario