ETS AP-30W Manual de usuario

AP-30W
Operang instrucons
Thank you for buying our air cleaner. Each system is carefully manufactured and subjected
to a test run to ensure safety and reliability. Please read the instrucons carefully before
inial use and save them for future reference.
www.ets-products.com

2
Table of contents:
* Voltage and frequency depend on the standard of the country or region in which the devices are
used. Device data can be found on the product label. Use only devices that are intended for your
region.
Speci ca ons:
Scope of delivery:
Air cleaner: 1, Power cable 1, Opera ng instruc ons: 1, Remote control: 1, Moun ng plate 1,
Moun ng dowels: 6
200 m³/h
220 V / 240 V
50 Hz
60 W
520 x 310 x 140
8,9 kg
5 °C – 40 °C
< 80%
~ 54 dB at the highest fan level
With Tuya app control
Scope of delivery Page 2
Speci ca ons Page 2
Areas of applica on Page 3
System overview Page 3
Wall moun ng Page 4
Control and display eld Page 5
Remote control Page 6
Tuya app control Page 7
Maintenance and cleaning Page 11
Filter replacement Page 12
Safety instruc ons Page 12
Air volume (CADR):
Mains voltage:*
Frequency:*
Power:
Dimensions (mm)
Weight:
Ambient temperature:
Rela ve humidity:
Noise level:
WiFi technology IEEE 802.11 b/g/n, 2,4 GHz
WiFi security WEP, WPA, WPA2
frequency 2,412 - 2,484 GHz
Transmission power < 20 dBm
Transmission range max. 50 m

3
Areas of applicaon:
System overview:
The system is equipped with a highly ecient ltraon and cleaning system including a HEPA
lter, an acvated carbon lter, a tanium oxide photocatalyst lter, a UV sterilizaon lamp
with a 254-nm wavelength, and a plasma generator.
ETS air cleaning systems are used to eecvely remove toxins, viruses, bacteria, pathogens,
dust, allergens, and odors from the ambient air.
1 Maintenance panel
2 TiO2 photocatalyst
3 Prelter
4 HEPA lters and acvated carbonlter
5 UV-C lamp
6 TVOC
7 Temperature/moisture sensor
8 PM2.5-Sensor
9 Fan
10 Plasma generator
11 Primary housing
12 Air cleaner rear wall
13 Wall-mounng plate
14 Control board
- Four-layer air lter and four-stage air cleaning
- High-precision parcle sensors and organic gas sensors installed for real-me air quality
tesng
- Remote control, manual controls, and night mode
- Four cleaning modes: 1) Manual, 2) Auto, 3) Quick cleaning, and 4) Night operaon with
cleaning and four fan levels
- Warning display for replacing the HEPA lter, acvated carbon lter, and UV lamp

4
Wall mounng:
> 20 cm
> 20 cm
> 40cm
1
2
3
4
Before xing the mounng plate to the wall, ensure
that there are no pipes or electrical cables in the
wall.
1. Leave more than 40 cm free to the right of the
plate. Leave more than 20 cm free above and to
the le of the plate. The mounng plate should be
placed near a power outlet.
2. Use a spirit level to mount the mounng plate in
the correct posion. Make six marks through the
holes in the mounng plate with a marking pen.
Drill holes of the proper size for the dowels in the
accessories package, and x the mounng plate
rmly to the wall.
3. Fix the air cleaner to the mounng plate using
the three adjustable pins.
4. Connect the air cleaner to the power source.

5
Control and display eld:
On/off
Auto mode
Timer
WiFi
Humidity
Air volume
Sleep mode
Sterilization
Temperature
A. On/off: Standby mode is green. On mode is white.
Touch the On/off icon to switch the air cleaner on or off. Standard mode is manual mode
with Air Volume Level 1 after the air cleaner is switched on.
B. Auto/manual: Manual is white, auto is green.
In manual mode: Air volume can be measured and the UV lamp switched on. In auto mode:
Sensors automatically measure the air volume for PM2.5 and TVOC. After five minutes in
auto mode, the UV lamp is automatically switched on, and after 30 minutes in auto mode,
it is switched back off.
C. Air speed: No backlighting on the user interface except for the sleep mode indicator.
D. Timer: Switched off – lit up white. Switched on – green. The air cleaner can be switched
off automatically in 1-9 hours.
E. Child safety: Switched on – lit up white.
Touch the screen to switch on child safety, and touch sleep mode and the timer for three
seconds to switch it back off. Child safety can be switched on and off with the remote
control.
F. Air volume: +/-. The air volume can be adjusted according to application environment.
G. UV: Switched off: Lit up white. Switched on – green.
H. Plasma is always on
I. Night mode: In night mode, the display lighting switches off, and the system no longer
runs at high fan levels.
Touchscreen-Display
Child safety

6
Remote control:
Sterilization
Timer
Dewcrease air volume
Dewcrease air volume
Increase air volume
On/off
Increase air volume
Sleep mode
Plasma
Not assiggned
Auto mode
Child safety

7
Tuya App control
1. Scan the QR code to download the Tuya
app or search for it. When it has been
downloaded, install it.
2. Start the Tuya app and click “Login”
(click “Register” before your rst use) or
“Test now” (some app funcons may not
be available without login).
3.Connect the device. Click Switch on
and press for ve seconds on the con-
trol panel unl the light on the control
panel light begins to ash. When the
AI buon is pressed for ten seconds, the
system switches to connecon mode so
that it can connect to the Tuya app. The
app automacally nds the system and
asks for the WiFi connecon data. Aer
the network ID and password are entered
into the app, the access data are transfer-
red to the system. The system then has in-
ternet access and can be controlled from
the internet. More operaon instrucons
can be found in the Tuya app manual.

8
4. Click AUTO SCAN; start locaon ser-
vices, WiFi (ensure that the cell phone and
the device are using the same network),
and Bluetooth; and click AUTO SCAN to
search for available devices nearby.
5. Click “NEXT” when the app has located
the available devices.
7. The app is automacally connected to
the device. Connecon can take 1-3 minu-
tes. Aer the “Successfully added” no-
caon, click “Finish”. Click the device name
(“Air cleaner”, for example).
6. Enter the account and the WiFi pass-
word for the device (ensure that the de-
vice uses the same network as the cell
phone with the same correct password).
Then click “NEXT”.

9
8. The app control interface now appears.
Click the icons to control the device remo-
tely. You can now control this device via
1. In the sengs interface, click next
to the device name.
2. Click “Enable device” to enable the
device.
How other users control the device via app.

10
3. Click “Enable a new user” to enter ano-
ther user’s account name.
4. If “Added successfully” is displayed, the
other user can now control the device, too.
Otros manuales para AP-30W
1
Tabla de contenidos
Otros manuales de Purificador de aire de ETS