ESI Access 5D Thermal Reader Manual de instrucciones

Page 1 of 106 0455-0271 Rev A
5D Access Thermal Reader
Administration Guide
This guide is for Administrators who need to prepare for, configure and operate the 5D Access Thermal
Reader.

Page 2 of 106 0455-0271 Rev A
Contents
1 Application Scope of the Manual___________________________________________7
2 Product Overview__________________________________________________________7
3 Product Appearance________________________________________________________8
4 Product Installation______________________________________________________9
5 Local Operations__________________________________________________________9
5.1
Initial Interface
___________________________________________________________ 9
5.2
Main Interface
_____________________________________________________________ 10
5.3
Ad Mode
____________________________________________________________________ 13
5.4
Mask/Temperature Measurement Interface
_____________________________________ 14
5.5
Activation Config
__________________________________________________________ 20
5.5.1 Basic Info ______________________________________________________________________22
5.5.2 Device Location _________________________________________________________________22
5.5.3 Network Setting _________________________________________________________________24
5.5.4 User Management _________________________________________________________________25
5.5.5 Activation Password _____________________________________________________________29
5.5.6 Admin Password __________________________________________________________________30
5.5.7 Authentication Scene ____________________________________________________________30
5.6
Door Opening Method
________________________________________________________ 32
5.6.1 Face Scan-based Door Opening ____________________________________________________32
5.6.2 Card Swiping-based Door Opening _________________________________________________33
5.6.3 QR Code-based Door Opening ______________________________________________________34
5.6.4 Remote Opening __________________________________________________________________34
6 Web Operations___________________________________________________________35
6.1
Login
______________________________________________________________________ 35
6.1.1 Preparation _____________________________________________________________________35
6.1.2 Logging In to the Web Interface _________________________________________________37
6.2
Photo
______________________________________________________________________ 40
6.2.1 Photo Naming Rules ______________________________________________________________40
6.2.2 Refreshing the Photo Library ____________________________________________________41
6.2.3 Exporting Records _______________________________________________________________41
6.2.4 Exporting Photos ________________________________________________________________41
6.2.5 Deleting a Photo ________________________________________________________________42
6.2.6 Exporting and Deleting Photos ___________________________________________________43
6.3
Parameter Configuration
____________________________________________________ 44
6.3.1 Common __________________________________________________________________________44
6.3.2 Network _________________________________________________________________________64
6.3.3 Image ___________________________________________________________________________65

Page 3 of 106 0455-0271 Rev A
6.3.4 Intelligent _____________________________________________________________________76
6.3.5 Events __________________________________________________________________________93
6.3.6 Storage _________________________________________________________________________98
6.3.7 Security ________________________________________________________________________99
6.3.8 System _________________________________________________________________________101
7 Live View_______________________________________________________________104
8 FAQs____________________________________________________________________106

Page 4 of 106 0455-0271 Rev A
Disclaimer
No part of this manual may be copied, reproduced, translated, or distributed in any form or by any means
without prior written consent from Estech Systems, Inc. (ESI).
The manual may be updated from time to time due to version upgrade or other reasons.
The manual is for reference only. All the statements, information, and suggestions contained herein do not
constitute warranties of any kind, express or implied.
Estech Systems, Inc. (ESI) shall not under any circumstances be liable for any special, consequential,
incidental or indirect damages arising from the use of this manual or Estech Systems, Inc. (ESI)'s product,
including but not limited to any loss of commercial profits, losses caused by missing data or documents,
and anomalies during product running or information leakage due to cyber-attacks, hacker attacks, or virus
attacks.
Privacy Rule for HIPAA
The Standards for Privacy of Individually Identifiable Health Information (“Privacy Rule”) establishes,
for the first time, a set of national standards for the protection of certain health information. The U.S.
Department of Health and Human Services (“HHS”) issued the Privacy Rule to implement the
requirement of the Health Insurance Portability and Accountability Act of 1996 (“HIPAA”).1The
Privacy Rule standards address the use and disclosure of individuals’ health information—called
“protected health information” by organizations subject to the Privacy Rule — called “covered
entities,” as well as standards for individuals' privacy rights to understand and control how their
health information is used. Within HHS, the Office for Civil Rights (“OCR”) has responsibility for
implementing and enforcing the Privacy Rule with respect to voluntary compliance activities and civil
money penalties.
A major goal of the Privacy Rule is to assure that individuals’ health information is properly protected
while allowing the flow of health information needed to provide and promote high quality health care
and to protect the public's health and well being. The Rule strikes a balance that permits important
uses of information, while protecting the privacy of people who seek care and healing. Given that the
health care marketplace is diverse, the Rule is designed to be flexible and comprehensive to cover
the variety of uses and disclosures that need to be addressed.
This is a summary of key elements of the Privacy Rule and not a complete or comprehensive guide
to compliance. Entities regulated by the Rule are obligated to comply with all of its applicable
requirements and should not rely on this summary as a source of legal information or advice. To
make it easier for entities to review the complete requirements of the Rule, provisions of the Rule
referenced in this summary are cited in the end notes. Visit our Privacy Rule section to view the
entire Rule, and for other additional helpful information about how the Rule applies. In the event of a
conflict between this summary and the Rule, the Rule governs.
HHS.gov/HIPPA

Page 5 of 106 0455-0271 Rev A
Safety Precautions
CAUTION!
The default password is used for your first login. T
o ensure account security, please change
the password after your first login. You are recommended to set a strong password (no less
than eight characters).
Before performing operations, be sure to carefully read through and observe safety specifications in this
manual.
•Screenshots provided in this document are used as examples only and the UI layout varies with
versions.
•Estech Systems, Inc. (ESI) (hereinafter referred to as "ESI") reserves the right to modify the content in
this manual without prior notice or prompt, but ESI does not ensure that this manual is completely error-
free.
•Subject to uncertain factors such as the physical environment, actual values of data may differ from the
reference values described here. In case of any question or dispute, the right of final interpretation
resides with ESI.
•Follow operational instructions in this manual when using the product. ESI is not responsible for
problems caused by the violation of the instructions. Thank you for your cooperation.
Environmental Protection
This product has been designed to comply with the requirements on environmental protection. For the
proper storage, use and disposal of this product, national laws and regulations must be observed.
Conventions
•The figures, charts or photos in this manual are used for illustration only, which may differ from the
actual product.
•Subject to uncertain factors such as the physical environment, actual values of some data may differ
from the reference values described here. In case of any question or dispute, the right of final
interpretation resides with ESI.
•Follow this manual when using the product. Professional guidance is recommended.
•National conventions used in this document are described as follows:
Format Description
Boldface Indicates buttons, menus, tabs, window names, dialog names, and parameter
names. For example, click OK or select Device Management.
" " Indicates messages. For example, "Hanging Up" is displayed on the interface.
>
Directs you to go to a multi-level menu. For example, go to Device
Management > Add Device. In this example, Add Device is a submenu under
Device Management.
•The symbols in the following table may be found in this manual. Carefully follow the instructions
indicated by the symbols to avoid hazardous situations and use the product properly.

Page 6 of 106 0455-0271 Rev A
Symbol Description
WARNING!
Contains important safety instructions and indicates situations that could
cause bodily injury.
CAUTION! Be careful. Improper operation may cause damage or malfunction to product.
NOTE! Means useful or supplemental information about the use of product.

Page 7 of 106 0455-0271 Rev A
1 Application Scope of the Manual
Table1-1 Application Scope of the Manual
Name
5D Access Thermal Reader with Thermal Detection Module
2 Product Overview
The 5D Access Thermal Reader is a face recognition access control product featuring high performance
and high reliability. The face recognition technology is perfectly integrated into the access control device,
which relies on deep learning algorithms to support face authentication in order to open the door and
achieve precise control of human movement in and out of secured areas. Moreover, using remote control
to open the door is also supported via an indoor monitor. Additionally, it can be widely applied to the
scenarios of building systems such as smart communities, public security, parks, and other important areas.

Page 8 of 106 0455-0271 Rev A
3 Product Appearance
1.Light supplement lamp 1 2.Camera 1
3. Infrared light supplement lamp 4.Camera 2
5.Light supplement lamp 2 6.Display screen
7. Pass-through indicator 8.Microphone
9. Card reading area 10.Loudspeaker
11.Reset 12.USB2.0
13.Network interface 14. Power input (DC 12V±25%)
15.20-pin interface 16.Tamper proof button

Page 9 of 106 0455-0271 Rev A
4 Product Installation
Please reference the 5D Access Thermal Reader Install guide.
Reference the Digital Thermal Detection Module Install Guide if installing the optional Thermal Detection
Module.
5 Local Operations
5.1 Initial Interface
When the Access Control Terminal is used for the first time or the factory defaults are restored, users need
to set the activation password, which is used to log in to the “Activation Config” interface.
NOTE!
The password must contain at least eight characters (including at least two
of the following
types: upper case letters, lower case letters, digits, underscores, and hyphens).
The activation password is consistent with the password for the admin to log in to the
Web interface. If the activation password is changed, use the new password to “log in to
the Web interface”.
After the activation password is configured, the “main interface of the 5D Access Thermal Reader” is
displayed. If the activation password needs to be changed later, refer to "Activation Password" to change
the password.
Figure5-1 Activation Password Configuration Interface

Page 10 of 106 0455-0271 Rev A
5.2 Main Interface
Figure5-2 Main Interface (Video Intercom Mode)
No. Description
1
Displays the current date, time, and connection status of different services.
Indicates the following items from left to
right:
Whether to enable the face scan mode
Whether an ID card reader is connected properly
Whether server 1 is online
Whether server 2 is online
NOTE!
An icon marked with indicates "No".
Otros manuales para Access 5D Thermal Reader
1
Tabla de contenidos
Otros manuales de Equipos de oficina de ESI