enware Custodian WMSSB-000 Manual de usuario

I00348_Jun 20
Installation and Maintenance Instructions
The Custodian
®
Smart Board
Call 1300 369 273
www.enware.com.au
Enware Australia Pty Limited
9 Endeavour Rd Caringbah NSW 2229 Australia
Ph: 02 8536 4000 info@enware.com.au
WMSSB-000 - without solenoids
WMSSB-001 - with solenoids

2 Call 1300 369 273 www.enware.com.au
product description
The Custodian®Smart Board directly controls and monitors the delivery of water in secure or
controlled bathroom environments. The compact and easy to install unit houses the Electronic
Thermostatic Mixing Valve (eTMV), eTMV Control Hub (WMSSB-000 model), with Basin/
Shower solenoids and service isolation/strainers and check valves (WMSSB-001 model).
Features:
• Rapid installation of pre-assembled and tested plumbing assembly
• Integrated control of water flow and thermostatic temperature control of shower and basin
• Toilet full and half flush connections
• Plug-and-play cable connectors for all fixtures and Smartflow Water Management System
The eTMV Control Hub is designed to be a generic smart hardware platform which is used for
multiple applications such as shower and basin tapware and toilet flush valves in domestic /
public / aged care / hospital / detention plumbing systems depending on the configuration.
The hub has a RS485 network interface to connect to either a local or cloud based water
management system. The network connection allows the hub to be configured, monitored
and updated remotely.
When activated, water is delivered to the shower or basin outlet at the selected thermostatic
temperature and for a pre-configured runtime. This is achieved by using an Electronic
Thermostatic Mixing Valve (eTMV) for temperature control and a solenoid for flow control. The
available activation methods depend on the configured mode.

www.enware.com.au Call 1300 369 27 3
260
340
445
297
310
95
315
187
63
90
100
57
41
SOLENOID
MIXED TO SHOWE
R
SOLENOID
MIXED TO BASIN
HOT INLET
ISOLATION, STRAINER
& CHECK VALVE COLD INLET
ISOLATION, STRAINER
& CHECK VALVE
ETMV
CONTROL HUB
ELECTRONIC TMV
TRANSFORMER
12V DC
All measurements are in millimetres.
The Custodian®Smart Board
(WMSSB-001 Model)
(WMSSB-001 Model)

4 Call 1300 369 273 www.enware.com.au
technical data - electronic tmv
Water Supply
Inlet Temperatures Cold: Min. 5°C Max. 30°C
Hot: Min. 55°C Max. 85 °C
Outlet Temperature Range
(Temperature limits and sengs controlled by
Smarlow System)
Min. 5 °C Max. 50 °C (+/- 2˚C)
Thermal Flush Temperature
(Temprorarily enabled by server, acvated on site)
Max. 70 °C
Dynamic Inlet Pressures Min. 100 kPa Max. 500 kPa
Dynamic Pressure Dierenal
Between Hot and Cold Supplies
Must be less than 100 kPa*
Stac Inlet Pressure
For Tesng Purposes / System Commissioning
Max. 1600kPa
Minimum Flow Rate 2 Litres/min
Maximum Flow Rate 32 Litres/min @ 300 kPa pressure loss
as per ow sizing graph
Inlet & Outlet Connecons 1/2" BSP Male
*AS3500.4 clause 1.9.4.2 - The dynamic pressure differential between hot and cold supplies when
mixed at a thermostatic mixing valve shall not exceed 10%.
Electronic Thermostatic Mixing Valve (eTMV)
eTMV Flow Sizing Graph
FLOW RATE VS PRESSURE LOSS
40
35
30
25
20
15
10
5
0
050 100 150 200 250 300 350 400
450
Flow rate ( litres / minute )
Dynamic pressure (kPa)
cold hot mixed

www.enware.com.au Call 1300 369 27 5
Power
Included Power Supply Input Requirements 100-240VAC 50/60Hz
Nominal Input Voltage 12VDC
Input Voltage Tolerance 10%
Typical Power Consumpon 1W
Maximum Power Consumpon 36W
Environmental Specicaons
Heat Output (BTU/HR) 3.4
Operang Temperature 5 - 50 °C
Communicaon Ports
Type of Port Smarlow Communicaon Port
Number of Connectors 1
Serial Port Protocol RS485
Serial Port Speed 38400 baud
Piezo Buon Ports
Number of Inputs 4
Type of Inputs Piezo Buons
Number of Connectors 2
Type of Connector KCC SK5/5 Male
TLI Control Wheel Port
Number of Connectors 2
Type of Connector KCC SK9/8 Male
Flushing Solenoid Ports
Number of Outputs 1
Type of Outputs 10W solenoid
Voltage of Outputs 12V
Number of Connectors 1
Connector Type KCC SK2/2 Female
eTMV Control Hub
technical data - eTMV control hub

6 Call 1300 369 273 www.enware.com.au
installation
1. The Custodian®Smart Board should be
securely fixed to a wall in close proximity
to the interface facia plate(s), flushing
solenoid, and within 1m of a 240VAC
GPO ideally located above the Smart
Board.
It should be placed in a clean dry
environment, in an access duct or service
duct or some other appropriate location
where it can be accessed for servicing.
Fix Smart Board to a wall, using
appropriate screws. SEE IMAGE 01
Enware products are to be installed in accordance with the Plumbing Code of Australia (PCA)
and AS/NZS3500. Installations not complying with PCA and AS/NZS 3500 may void the
product and performance warranty provisions.
Reference should also be made to the Australasian Health Facility Guidelines (AHFG), ABCB
and Local Government regulations when considering the choice of, and the installation of
these products.
NOTE: Enware Australia advises:
1. Due to ongoing Research and Development, specifications may change without notice.
2. Component specifications may change on some export models.
For use with potable water only.
installation compliance
IMAGE 01

www.enware.com.au Call 1300 369 27 7
2. Flush water supply lines and ensure the
lines are clear of any debris.
3. Connect water lines to each connection.
SEE IMAGE 02
CONNECTION TO SHOWER
CONNECTION TO BASIN
COLD INLET
1/2” BSP MALE
HOT INLET
1/2” BSP MALE
IMAGE 02
ETMV OUTLET
CONNECTION
COLD INLET
1/2” BSP MALE
HOT INLET
1/2” BSP MALE
WMSSB-001 Model
WMSSB-000 Model

www.enware.com.au Call 1300 369 27 8
Control Hub Overview
SN3SN2SN1ETMV
12V
DC
RS485
B1,B2
TLI1
TLI3
B3,B4
eTMV Control Hub Cable Connections
1. Connect cable connections for the control plate(s) and flushing solenoid to eTMV Control
Hub.
The cable connections should be plugged into the eTMV Control Hub in the location
marked with the same designator - e.g. “w1” should be connected to the other cable
labeled “w1”.
Care should be taken with the position and orientation of the connections. Align white
marking on the connectors when connecting. When unplugging cables, hold the cable
connectors themselves, and do not pull on the cables.
Follow the installation instructions for eTMV Control Panel for correct cable connections.
2. Connect RJ45 Network cable to the surface mount RJ45 Jack.
The main Backbone Cable will have already been installed and a surface mount RJ45
Jack will be fitted less than 1m above the Custodian Smart Board location.
3. Finally connect the power supply (supplied transformer) to power the Custodian®Smart
Board.

9 Call 1300 369 273 www.enware.com.au
eTMV Control Hub Connections
• 1x RJ45 network cable for communications and updates (external)
• 1x power supply input (external)
• 4x piezo button inputs (external)
• 2x TLI control wheels (external)
• 1x ETMV output (on Smart Board)
• 2x shower / basin solenoid outputs (on Smart Board)
• 1x flushing solenoid output (external)
ETMV CONTROL HUB
SHOWER SOLENOID
BASIN SOLENOID
FLUSH SOLENOID
SHOWER TLI
BASIN TLI
ETMV
SHOWER AND BASIN
ACTIVATION BUTTONS
FULL AND HALF FLUSH
BUTTONS
SN2
SN1
SN3
B1,B2
B3,B4
W1
W3
ETMV
Smart Flow RS485
RS485
12VDC
12V POWER PACK

10 Call 1300 369 273 www.enware.com.au
operation
Piezo Button Activation
WC HALF FLUSH
ACTIVATION
WC FULL FLUSH
ACTIVATION
BASIN OUTLET
ACTIVATION
SHOWER
ACTIVATION
PRESS ONCE TO ACTIVATE
CONTROL PANEL
IMAGE 03
Lightly press the piezo button once to activate. SEE IMAGE 03
Este manual sirve para los siguientes modelos
1
Manuales populares de Electricidad industrial de otras marcas

S&C
S&C Vista SD Manual de usuario

Murata
Murata GRM0335C2A7R3CA01 Series Manual de usuario

Siemens
Siemens 3VA9988-0BM10 Manual de usuario

Siemens
Siemens SITRANS LVS100 Manual de usuario

Murata
Murata GRM32ER60G227ME05 Series Manual de usuario

Siemens
Siemens SENTRON SUPERSWITCH 3KL82 Series Manual de usuario