Precautions for
use .................................................................03
Products .....................................................................04
Control Panel - Remote Control
Panel ..........................................................05
Use .......................................................................06
Charging the battery via the
mains .............................................................09
Environment of
use ....................................................................09
Tent
placement ....................................................................10
Connecting
windows ....................................................................11
Cold Air Extension Duct Installation

3
Instructions ...........................................................11
Troubleshooting ...................................................................
..12
Cleaning and
maintenance ....................................................................12
Packing
list .....................................................................13
Environmental
Checklist .....................................................................14
Warranty
Card .....................................................................15
Precautions for use
This manual contains important safety information on the proper use and maintenance of air
conditioners to prevent personal injury or property damage to users and others,Please read the
text with full understanding of the following (signs, icons) and be sure to observe the safety
instructions provided.
Note: This symbol indicates that personal injury or property damage may be caused.

4
➢The product must be repaired or maintained by a professional and it is forbidden to disassemble,
modify, repair or clean the internal components without permission;
➢This product must not be operated by children, persons lacking physical, sensory or mental capabilities
and adults who do not understand the contents of this manual;
➢The power supply must be disconnected before cleaning or other maintenance is carried out;
➢Do not install this product in an area where combustible gases are exposed. If combustible gases
accumulate they may cause a fire;
➢Do not cover the power cord with a carpet or similar covering, do not place the cord under furniture
or other electrical appliances, and arrange the cord away from traffic areas or where it will not be
tripped over;
➢Turn off the machine in case of thunderstorms when using outdoors to avoid lightning damage to the
machine;
➢Do not cover the air outlet, air inlet, exhaust air outlet and suction air inlet while the machine is in
operation and do not use the air outlet and exhaust air outlet to air dry and dry objects and clothing.;
➢Mount the unit on a solid flat surface, otherwise damage or excessive noise and vibration may result;
➢Do not drop or damage the equipment.
Warning: This symbol indicates that death or serious injury may result
➢Installation must be carried out in accordance with the installation instructions. Improper installation
can lead to water ingress, leakage, electric shock or fire;
➢Use only the accessories and parts supplied and the specified tools for installation. Use of non-
standard parts may result in water leakage, electric shock, fire, injury or property damage;
➢Ensure that the socket you use is earthed and of the correct voltage. Equipped with a power cord with
a three-pronged grounded plug to prevent electric shocks.
➢It is forbidden to change the power cord without permission. Improper use of the power supply can
cause fire or electric shock.
➢If the power cord is damaged, it must be replaced by the manufacturer, the service department or a
specialist in order to avoid danger.;
➢Do not install the air conditioner in a humid room such as a bathroom or laundry room as this may
cause a short circuit in the electrical components;
➢To reduce the risk of fire or electric shock, do not use this air conditioner in conjunction with any solid
state speed control device.
Precautions for fluorinated gases
➢This air conditioning unit is a sealed unit containing fluorinated gas. For information on the specific
type of gas and the quantity, please refer to the relevant label on the unit.
➢This device does not support users to add their own refrigerant;
➢Maintenance or repair of this equipment must be carried out by certified technicians;
Please separate this product from household waste when it is scrapped. The scrapping must comply
with local waste disposal regulations and the power cord must be disconnected before scrapping so
that the equipment cannot be used again.

5
Note
All images in this brochure are for reference only and your air conditioner may vary slightly depending on
the model.
Introduction to the main components
⚫This product is equipped with a new 24v high performance compressor, a new double pipe exhaust
system and a classic carry handle for easy mobility; with the use of a special battery it can achieve a
maximum continuous working time of approximately 5 hours at high frequencies.
⚫Mainframe
⚫Accessories
Design and normative notes
➢Design Note: To ensure optimum performance, the design specifications and remote control of the
equipment are subject to change without notice;
➢Energy rating information: the energy rating of the machine is based on the use of an extended
exhaust pipe;
➢The batteries exemplified in this manual have to be purchased separately and the maximum operating
times are measured under experimental conditions and are for reference only;
This product already has a set of intake and exhaust pipes built in, if a longer exhaust pipe is required,
please get details from your dealer.

6
Control Panel - Remote Control Panel
Power button
⚫With the power on, press this button once to switch on when operating with the
control panel and press and hold for 3 seconds to switch off.
⚫With the power on, press this button once to switch on and once to switch off
when operating with the remote control panel.
Cooling mode
⚫Default is cooling low air 22°C/72°F when switched on;
⚫Other modes Press this button to enter cooling mode.
Strong mode button
⚫Press the "strong" button to put the air conditioner into power mode, with the air conditioner
working at full capacity.
+ button
⚫Increase the temperature setting by 1°C per press of "+" (31°C Max), not valid
in Power mode.

7
- button
⚫Lower the temperature setting by 1°C per press of "-" (16°C Min), not valid in
Power mode.
Wind speed button
⚫In cooling mode the "air speed" button switches the frequency and air speed to
three different operating modes (F1 strong air speed mode, F2 medium air speed
mode, F3 light air speed mode);
⚫Still available in strong mode, sleep mode. Simply switch the air speed and the
mode automatically changes to work with 3 adjustable air speeds.
Sleep mode button
⚫Press the "Sleep" button to put the air conditioner into sleep mode, with the air conditioner working
at low load.
Remote control battery cell use
Use
Can be used with the original power adapter or special batteries
Specifications of the device adapter: Input voltage: AC100-240V ~ 50-60Hz, output voltage: DC24V,
power: 240 W

8
⚫Power supply via adapter:
① Air conditioning power connectors ②Power adapters ③Home AC 100-240V(50-60Hz)
Note: Use the adapter provided by the original manufacturer, do not use a third party adapter (to
avoid unnecessary electrical hazards).
⚫Powered by battery:
Battery coupling illustration:①Docking position ②Rotate to a fixed position ③Wiring (with
power cable to connect the battery to the air conditioner) ④Turn on the battery switch.
Battery removal illustration :①Turn off the battery switch ②Remove the power cable
③Rotation ④Remove

9
1. Accessory connections
Connecting the drain
Accessory connection to the upper connection drain
The unit turns gaseous water in the air into a liquid, just like a conventional air conditioner, and it uses
gravity to collect and discharge the water produced. Its interior can store condensed water for
approximately 1-2 hours, depending on the humidity of the air.
2. Connect the drainage hose to the drainage outlet. Place the open end of the hose directly in the
drainage area of the basement or in another container.
Take care that the drain hose is placed so that it does not come into contact with the power supply.
Keep the hose firmly connected, free from leaks and kinks, place the end of the drain hose into the drainage
area and ensure that the end of the hose is facing downwards to allow water to flow smoothly. Do not lean
forward or to the side when working or handling as water may leak out of the front or sides.
3. Translated with www.DeepL.com/Translator (free version)
Connecting extension tubes

10
⚫Take care to keep it level in use. It is best to tilt it backwards by 5-10 degrees, not forwards or from
side to side, otherwise condensate will leak out of the front, and bottom of the air conditioning unit.
⚫Do not move the air conditioner immediately after use. Please tilt the air conditioner back slowly by
30 degrees to ensure that any water left in the air conditioner is drained.
Note: If water leaks due to improper placement, do not be nervous, just wipe it clean or cool it
naturally, it will not affect the performance of the machine.
Charging the battery via the mains