Quick Start
This new version of Accessor features several enhancements:
... the ability to add new users at the unit, without a PC
... any Level 1 Master code can now be used to mount or
unmount the unit from its mounting bracket
... added the Level 4 Lockout Mode (in lieu of Privacy)
Please follow the steps below to get your new Accessor
up and running as smoothly & easily as possible.
1) Unpack the Accessor and attach the mounting bracket to a
suitablelocation.Gateunitsmustberemovedfromthemounting
bracket prior to installation, see section 3 page 11.
2) New codes may be added at the box (see step 3) or by using
ACE ™ version 1.30 or greater. ACE ™ is available via a free
download at our website, engsolinc.com.
3) Program in new codes at the unit as follows:
... add a new Level 1 Master
(remember this code)
FCN →→
→→
→1234567 →→
→→
→New Master →→
→→
→1 →→
→→
→FCN
... test new Level 1 Master by deleting default Level 1 Master
FCN →→
→→
→New Master →→
→→
→1234567 →→
→→
→FCN
... confirm the default Level 1 Master is deleted
1234567 (unit should beep & illuminate the red LED)
... add any other new codes you need
(repeat as needed)
FCN →→
→→
→New Master →→
→→
→New Code →→
→→
→Level (1-4) →→
→→
→FCN
4) Mount the Accessor on its mounting bracket:
... enter your new Master code & lift open the keybox
... position unit on the mounting bracket, then while holding
the keybox open re-enter the new Master code
FCN →→
→→
→New Master →→
→→
→FCN
... slide the unit down, after 10 seconds the latch will move
out of the way allowing the keybox to relock
Congratulations! Your Accessor is ready to go!