Energetech Solar PB5000 Manual de usuario

POWER BANKS STORAGE SYSTEM
User Manual
Version: 2.0
PB5000 (51.2V 100AH-5.12Kwh)
PB7000 (51.2V 150AH-7.68Kwh)
PB10000 (51.2V 200AH-10.24Kwh)
For On / Off Hybrid Solar Storage System

- 1 -
Contents
1. Safety Precautions ....................................................................................................................................... - 2 -
1.1. Before Connecting .................................................................................................................................................. - 2 -
1.2. During operation ..................................................................................................................................................... - 2 -
2. Battery Specifications ................................................................................................................................. - 3 -
3. Introduction to the battery ........................................................................................................................... - 4 -
3.1. Key Features .......................................................................................................................................................... - 4 -
3.2. Interface Introduction .............................................................................................................................................. - 4 -
3.3. SOC Indicator & Status Indicator Guides ................................................................................................................. - 5 -
3.4. Connectors ............................................................................................................................................................. - 7 -
3.5. Wake Up button ...................................................................................................................................................... - 7 -
3.6. Display function instruction ...................................................................................................................................... - 7 -
3.6.1. Reference of real figure .................................................................................................................................... - 7 -
3.6.2. Screen Display ................................................................................................................................................. - 7 -
3.6.3. Functional Specifications .................................................................................................................................. - 8 -
4. Safe handling guide ................................................................................................................................... - 11 -
4.1. System Diagram ................................................................................................................................................... - 11 -
4.2. Tools ..................................................................................................................................................................... - 11 -
4.3. Safety Gear ........................................................................................................................................................... - 11 -
5. Installation .................................................................................................................................................. - 12 -
5.1. Inventory of items .................................................................................................................................................. - 12 -
5.2. Installation Location .............................................................................................................................................. - 13 -
5.2.1. Minimum clearances ....................................................................................................................................... - 13 -
5.3. Installing the Battery Pack ..................................................................................................................................... - 14 -
5.3.1. Mounting to a wall .......................................................................................................................................... - 14 -
5.4. Parallel use of battery............................................................................................................................................ - 16 -
5.4.1. Parallel use of battery ( All off grid solar inverters ) ........................................................................................ - 16 -
5.4.2. Parallel use of Energetec battery on Canbus /RS485( All hybrid on-off grid solar inverters) ............................. - 18 -
5.4.3. ADS guide Line .............................................................................................................................................. - 18 -
6. Product Warranty ....................................................................................................................................... - 21 -
6.1. .............................................................................................................................................................................. - 21 -
6.2. .............................................................................................................................................................................. - 21 -
6.3. .............................................................................................................................................................................. - 21 -
6.4. Factory Warranty Scope ........................................................................................................................................ - 21 -
6.5. Warranty conditions .............................................................................................................................................. - 21 -

- 2 -
1.Safety Precautions
It is very important and necessary to read the user manual carefully before installing or using the
battery. Failure to follow any of the instructions or warnings in this document can result in
electrical shock, serious injury, death, or may damage the battery and the whole system.
If the battery is stored for a prolonged time, it is requirement that they are charged every three to
six months, and the SOC should be no less than 80%.
The battery needs to be recharged within 12 hours, after fully discharging.
Do not expose cable outside.
All battery terminals must be disconnected before maintenance.
Do not use cleaning solvents to clean the battery.
Do not expose the battery to flammable or harsh chemicals or vapors.
Do not paint any part of the battery, include any internal or external components.
Do not connect battery with PV solar wiring directly.
Any foreign object is prohibited to be inserted into any part of the battery.
Any warranty claims are excluded for direct or indirect damage due to items above.
1.1.Before Connecting
After unpacking, please check the battery and packing list first, if the battery is damaged or spare
parts are missing, please contact the dealer.
Before installation, be sure to cut off the grid power and make sure the battery is in the turned-off
mode;
Wiring must be correct, do not mix-connect the positive and negative cables, and ensure no short
circuit with the external device;
It is prohibited to connect the battery with AC power directly;
The embedded BMS in the battery is designed for 48VDC, please DO NOT connect battery
in series;
It is prohibited to connect the battery with different type of battery;
Please ensure the electrical parameters of battery system are compatible to inverter;
Keep the battery away from fire or water.
1.2.During operation
If the battery system needs to be moved or repaired, the power must be cut off first and the
battery is completely shutdown;
It is prohibited to connect the battery with different type of battery;
It is prohibited to put the batteries working with faulty or incompatible inverter;
In case of fire, only dry powder fire extinguisher can be used, liquid fire extinguishers are
prohibited;
Please do not open, repair or disassemble the battery. We do not undertake any consequences
or related responsibility due to violation of safety operation or violating of design, production and
equipment safety standards.

- 3 -
2.Battery Specifications
Battery Specifications
Model No PB5000 PB7000 PB10000
Nominal Parameters
Voltage 51.2V 51.2V 51.2V
Capacity 100Ah 150Ah 200Ah
Energy 5.12KwH 7.68KwH 10.24KwH
Dimensions (L x W x H) 680 x480 x180(220)mm 680 x480 x180(220)mm 680x480x180(220)mm
Weight 60.50kg 78.0 kg 105.5kg
Basic Parameters
Life time(25°C) 20 years
Life cycles(80% DOD, 25°C) 6000 Cycles
Storage time / temperature 5 months @ 25°C; 3 months @ 35°C; 1 month @ 45°C
Operation temperature -20°C to 60°C @60+/-25% Relative Humidity
Storage temperature 0°C to 45°C @60+/-25% Relative Humidity
Lithium Battery Standard IEC62133, IEC62619,UN38.3,ROHS,CE-EMC,MSDS
Enclosure protection rating IP21
Electrical Parameters
Operation voltage 51.2 Vdc 51.2 Vdc 51.2 Vdc
Max. charging voltage 56Vdc 56Vdc 56 Vdc
Cut-off Discharge Voltage 46 Vdc 46 V dc 46 Vdc
Max. charging and discharging
current 150A(7680W) 150A(7680W) 200A(10120W)

- 4 -
3.Introduction to the battery
3.1.Key Features
LiFePO4 composition – provides exceptional safety and longevity
High safety and reliability
6,000cycles/ 20 years’ service life
Consistent performance over wide temperature range
Wall-mounted, convenient installation
Integrated state-of-the-art BMS to manage and monitor battery information including voltage,
current and temperature as well as balance cell charging/discharging rates
10 years’ warranty
3.2.Interface Introduction
This section details the interface functions of front and back panel..
Front interface:

- 5 -
No
. Description Silk-screen Remark
1
D
ial switch
ADS
Set the address
2
CAN port
CAN
CAN port
3
RS485 port
RS485
RS485 port
4
RS485 port
RS485
RS485 port
5
Port Reset
button RST For reset the batter
6
Bracket
7
Switch
OFF/ON
Normal close
8 Anderson
connector - +
Input
/Output
terminal
9
Handle
10
LED
ALM
Alarm indicator
11
LED
RUN
Operation indicator
12
LED
CAPACITY
Capacity indicator
13
LCD
14
LCD KEY
3.3.SOC Indicator & Status Indicator Guides
Chart 1: Battery Status

- 6 -
Chart 2: Battery Capacity
Chart 3: Battery status

- 7 -
3.4.Connectors
Charge / Discharge connectors: to connect the positive pole (+) and negative pole (-) from the
battery to the inverter via DC isolator.
Canbus Active communication portal between battery and inverter.
USB To RS485: to get dynamic monitoring data of the battery from upper computer.
Address: Reserved Address portal for multiple parallel connections.
3.5.Wake Up button
Battery On: When battery is shut down, press this RST button for 6 seconds. It is activated
when the LED lights flicker from RUN light to the lowest capacity indicator.
Battery off: When battery is activated, press this button for 6 seconds. It will be shut down
when the LED lights flicker from lowest capacity indicator to RUN light.
3.6.Display function instruction
3.6.1.Screen Display

- 8 -
3.6.2.Functional Specifications
Interface introduction
Main menu page
Electricity/dormancy activated, will show the welcome screen, press the MENU button to enter
the main menu page. As shown in the figure below:
Battery cells state

- 9 -
Battery temperature
Battery Warning
Este manual sirve para los siguientes modelos
2