taking into account the optimum
mounting / detection height (2M). Make
sure there is sufficient cable coming out
of the wall to connect to the terminal
block. Ensure that the mounting surface
is solid, preferably a brick or block wall
and ensure that there are no other cables
or pipes beneath the surface.
2. Diagram A. Fit the 2 threaded posts in
the back plate and bring the mains cable
through the rubber grommet then use the
back plate as a template and mark the 2
fixings holes, making sure the back plate
is the correct way up and the threaded
bolts are horizontal. Use appropriate
fixings to secure the back plate to the
wall.
3. Diagram B. Connect the house wiring to
the internal terminal block. The cable
entry grommet and the back plate seal
must be securely in place to ensure that
the water ingress protection is
maintained. NOTE: This is a Class I
fitting and must be earthed. Connect
the incoming mains as per the diagram
4. Diagram C. Fit the terminal block onto
the post in the back plate and then fit the
front frame over the 2 threaded bolts in
the back plate. Secure with the 2
threaded nuts / clear washers. Take care
not to trap or strain the internal cables..
5. To Test the Lantern. Turn on the
power. To test the PIR unit in daylight,
turn both the timer dial (TIME) and the
Sensitivity dial (SENS) gently fully anti-
clockwise with the blade of a small screw
driver. Activate the PIR by covering the
PIR lens with your hand. The unit will
light and should stay on for
approximately 5-15 seconds then go off.
It will remain off until the light level drops.
6. To adjust Time On. By adjusting the
TIME dial the unit will stay on (once
activated) from 5 -15 seconds (fully anti-
clockwise) to 3 -5 minutes (Fully
clockwise).
7. To adjust sensitivity – detection
distance.By adjusting the SENS dial the
detection distance can be changed –
minimum detection is fully anticlockwise -
or maximum detection distance is dial
turned fully clockwise.
NOTE:-
1. All time on values are approximate.
2. At initial power-on activation, the
lantern will switch on and may remain
on for up to 2 minutes. Keep out of the
way of the activation zone and once
the light goes off make the setting
adjustments.