IRB-325 Instructions 3
Document no. REV 1.0 Date 10/25/2007
Product Overview
The IRB-325 conforms to the UL325 standard when used with the powder coated steel
hoods. Registration reference number 9901994. The IRB-325 photocell is used as an
external entrapment protection device type B1 non-contact sensor for use with automatic gate
and door openers.
The IRB-325 transmitter and receiver have a line of site range of up to 65 feet. The IRB-325
operates on 12 VDC to 24 VAC and draw 150 mA maximum.
The IRB-325 receiver is activated whenever anything interrupts the beam from the
transmitter, triggering the relay output to change state and send a signal to the operator that
there has been an interruption.
Technical Specifications
Controls, Indicators and Connections
Transmitter Receiver
The IRB-325 is an external entrapment device Type B1 non-contact sensor for use
with automatic gate operators. If the IRB-325 is used as the primary entrapment
protection device it must be monitored for presence and fault condition.
Power Supply 12 Volts Dc to 24Volts AC
Power Supply Tolerance +/- 20%
Current Draw 150 mA maximum
Housing Material UL and CSA Type 4, 4X, 3, 3R, 12, 13 rating and powder coat steel hood
Relay Type Type C Rating 1A @ 30 VDC
Temperature Range -40oF to 170oF
Connector Screw terminal isolated contact (2) transmitter (5) receiver
Power Indicator Green LED
Detect Indicator Red LED
Dimensions H=5.03 in, W=3.06 in, D=3.02 in
Range 6 feet to 65 feet line of sight
Power LED
Green SMT glows when power is applied
Power LED
Green SMT glows when power is applied
Connections Screw terminal
2 position for power source
Connections Screw terminal
5 position for power and controls
Detect LED
(2) Red SMT LEDs glow on detection