Emulex LP850 Manual de usuario

LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 1of 10
Copyright Emulex Corporation - All rights reserved, 1999
Prerequisites:
lOne open 32-bit or 64-bit PCI bus slot with a 3.3 VDC or 5.0 VDC signaling interface
lMaximum PCI bus clock rate of 33 MHz
lMedia and connectors (user supplied; view supported media types.)
Follow these procedures to assemble and install the host adapter. Click procedures for
details. When finished, click "Return to top of page" to return to this summary.
1.Record reference numbers. Write down the host adapter's IEEE address and serial
number.
2.Install the host adapter board. Insert the host adapter board into a PCI slot on the
computer's motherboard.
3.Attach media. Connect fiber optic or copper duplex cabling to the host adapter.
4.Apply power. Apply power to the computer and observe the LED display.
After the host adapter is installed, install device drivers or run a DOS diagnostic program to
check host adapter functions or update firmware.
Record reference numbers
Each host adapter is shipped with a unique address identifier called the IEEE address. The
Fibre Channel industry uses a World Wide Name (WWN) derived from the IEEE address,
and this number is need for arbitrated loop connectivity. The serial number is used when
communicating with Emulex. Both numbers are clearly marked on the board. We
recommend that you record these numbers before installation.
Return to top of page.
Install the host adapter board
1.Turn off and unplug the computer.
2.Remove the computer case.
3.Remove the blank panel from an empty 32 or 64-bit PCI bus slot.
4.Insert host adapter board into the empty 32 or 64-bit PCI bus slot. Press firmly until
seated.
5.Secure the host adapter's mounting bracket to the case with the panel screw.

LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 2of 10
Copyright Emulex Corporation - All rights reserved, 1999
6.Replace the computer case and tighten case screws.
The host adapter is now installed in the PC. Continue with the attach media section.
Return to top of page.
Attach media
Select one of these types of media supported by the Emulex host adapter:
lMultimode fiber optic cable (50/125 µm or 62.5/125 µm)
lCopper duplex cable
If necessary, use an MIA to connect fiber optic cabling to a host adapter's copper DB9
connector.
Return to top of page.
Fiber optic cable (multimode)
More Information: View fiber optic specifications.
These cables support a data rate of 1.0625 Gb/s for short wave and long wave lasers.
Fiber Optic Cable Maximum
Length Minimum
Length Connector
62.5/125 µm
(multimode) 175 meters 2 meters Dual SC
50/125 µm
(multimode) 500 meters 2 meters Dual SC
9/125 µm (single
mode) 10,000 meters 2 meters Dual SC
1.Connect the fiber optic cable to the dual SC connector on the host adapter board as
shown below.
To attach fiber optic cable to a host adapter's copper DB9 connector, use an MIA.

LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 3of 10
Copyright Emulex Corporation - All rights reserved, 1999
2.Connect other end of cable to Fibre Channel device.
After the media is connected to the host adapter, you are ready to apply power to the
computer.
Return to top of page.
Copper duplex cable
TechNote: View copper specifications.
Cable Type Maximum
Length Data Rate Connector
Dual Twinax
or Quad Axial 30 meters 1.0625 Gb/s DB9
1.Connect the copper duplex cable to the DB9 connector on the host adapter board as
shown below.

LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 4of 10
Copyright Emulex Corporation - All rights reserved, 1999
2.Connect other end of cable to Fibre Channel device.
After the media is connected to the host adapter, you are ready to apply power to the
computer.
Return to top of page.
Apply Power
1.Verify the host adapter is securely installed in the computer.
2.Verify correct media is attached.
3.Plug in and turn on computer.
4.Observe LEDs for Power On Self Test (POST) results.
Return to top of page.
Power On Self Test and LEDs
Green and yellow display lights (LEDs) can be seen through openings in the host adapter's
mounting bracket. Green indicates power and yellow signifies port activity.
This chart shows normal LED indications. For other LED patterns, refer to the detailed LED
chart.
Green LED Yellow
LED State
OFF flashing
(irregular) POST processing in progress
ON blink normal - active - link up
blink OFF normal - link down or not yet started
Host adapter installation is complete. At this point, you should install a driver or run the
DOS diagnostic utility. Return to index to choose.
Return to top of page.

LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 5of 10
Copyright Emulex Corporation - All rights reserved, 1999
LP850 Additional Information
LP850 Host Adapter Specifications
Parameter Range
Hardware Interface 20 pin connector for GBIC models
Physical Dimensions Short PCI form factor 6.88" x 4.20"
Power Requirements 11 watts @ + 5.0 VDC (typical)
Airflow 100 lfm minimum
Temperature Operating: 32° to 113°F (0° to 45°C)
Storage: 14° to 131°F (-10° to 55°C)
Humidity 5% to 95% non-condensing
Agency Approvals for
LP850-D1
UL recognized to UL1950
CUR recognized to CSA22.2, No. 950
TUV certified to EN60950
FCC Rules, Part 15, Class A
Industry Canada, ICES-003, Class A
EMC Directive 89/336/EEC (CE Mark)
EN55022, Class A
EN50082-1
Australian EMC Framework (C-Tick Mark)
AS/NZS 3548:1994, Class A
VCCI, Class A.
Agency Approvals for
LP850-N1/T1
and LP850-F1
Class 1 Laser Product per DHHS 21CFR (J) & EN60825
UL recognized to UL1950
CUR recognized to CSA22.2, No.950
TUV certified to EN60950
FCC Rules, Part 15, Class B
Industry Canada, ICES-003, Class B
EMC Directive 89/336/EEC (CE Mark)
EN55022, Class B
EN50082-1
Australian EMC Framework (C-Tick Mark)
AS/NZS 3548:1994, Class B
VCCI, Class B
MIA
A Media Interface Adapter (MIA) is an adapter that allows you to convert from fibre optic
cable to copper. The adapter has two signal interfaces: an optical interface (SC connector)
and a serial interface (DB9 connector). By connecting an MIA to a copper DB9 connector on
a host adapter, a non-Open Fiber Control (non-OFC) optical link is provided. The Emulex
host adapter with a copper interface is designed to support an MIA that conforms with the
Fibre Channel - Media Interface Adapter specification.

LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 6of 10
Copyright Emulex Corporation - All rights reserved, 1999
Note An MIA is user supplied.
To attach an MIA,
1.Connect the MIA DB9 connector to the host adapter copper
DB9 connector.
2.Tighten screws carefully - do not over tighten.
3.Connect the SC connector of the fiber optic cabling to the
optical SC port of the MIA.
For more information on MIA specifications and operating instructions, consult the MIA
manufacturer’s documentation.
Supported media types
lMultimode fiber optic cable (50/125 µm or 62.5/125 µm) with dual SC connectors,
used with short wave lasers
lCopper duplex cabling with DB9 connectors (also called DE9)
lMedia Interface Adapter (MIA) used to convert from fiber optic to copper, if required
(user supplied)
Host Adapter LEDs
POST conditions and results are summarized in this table.
Green LED Yellow
LED State
OFF OFF wake-up failure (dead board)
OFF ON POST failure (dead board)
OFF slow
blink (1
Hz) wake-up failure
OFF fast blink
(4 Hz) failure in POST
OFF flashing
(irregular) POST processing in progress

LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 7of 10
Copyright Emulex Corporation - All rights reserved, 1999
ON OFF failure while functioning
ON ON failure while functioning
ON slow
blink (1
Hz) normal - inactive
ON flashing
(irregular) normal - active
ON fast blink
(4 Hz) normal - busy
slow blink OFF normal - link down or not yet started
slow blink slow
blink (1
Hz) off-line for download
slow blink fast blink
(4 Hz) restricted off-line mode (waiting for restart)
FCC and Regulatory Notices
Class 1 Information Label
CLASS 1 LASER PRODUCT
LASER KLASSE 1
LUOKAN 1 LASERLAITE
APPAREIL A` LASER DE CLASSE 1
TO IEC 825-1 (1993) + CENELEC HD 482 S1
The above statement applies to products marketed in the European Union.
FCC and VCCI
Model LP850-D1 (Copper Model)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.

LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 8of 10
Copyright Emulex Corporation - All rights reserved, 1999
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to
part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in a residential area is
likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense. Shielded cables must be used between this equipment and attached peripheral devices. The reader is
cautioned that changes or modifications made to the equipment not expressly approved by Emulex could void
the user’s authority to operate this equipment.
The above statement applies to products marketed in the USA
This class A digital apparatus meets all requirements of the Canadian Interference - Causing Equipment
Regulations. Cet Appareil numerique de la classe A respecte toutes les exigences du reglement sur le material
brouilleur du Canada.
The above statement applies to products marketed in Canada.
FCC Compliance Information Statement; Models LP850-T1/N1 (GBIC Models)
FCC Compliance Information Statement; Model LP850-F1 (1 X 9)
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Responsible Party: Paul Folino, President & CEO, Emulex Corporation, 3535 Harbor Blvd., Costa Mesa, CA
92626, USA, (714) 662-5600

LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 9of 10
Copyright Emulex Corporation - All rights reserved, 1999
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
lReorient or relocate the receiving antenna.
lIncrease the separation between the equipment and receiver.
lConnect the equipment into an outlet on a circuit different from that to which the receiver is connected.
lConsult the dealer or an experienced radio/TV technician for help.
The reader is cautioned that any changes or modifications to the equipment not expressly approved by Emulex
could void the user’s authority to operate this equipment.
This class B digital apparatus meets all requirements of the Canadian Interference - Causing Equipment
Regulations. Cet Appareil numerique de la classe B respecte toutes les exigences du reglement sur le material
brouilleur du Canada.
The above statement applies to products marketed in Canada.
VCCI Notices and Translations (Japan Only)
Note VCCI regulations provide that changes or modifications
not expressly approved by Emulex Corporation could
void your authority to operate this equipment.
Models LP850-T1/N1 (GBIC Models)
This is a Class B product based on the standard of the Voluntary Control Council for Interference by
Information Technology Equipment (VCCI). If this equipment is used near a radio or television receiver in a
domestic environment, it may cause radio interference. Install and use the equipment according to the
instruction manual.
Model LP850-D1 (Embedded Copper Model)
Product Label

LightPulse LP850 Fibre Channel PCI Host Adapter Manuals Page 10 of 10
Copyright Emulex Corporation - All rights reserved, 1999
Translation:
This is a Class A product. In a domestic environment this product may cause radio interference in which case
the user may be required to take adequate measures. VCCI—A
Manual Notice
Translation:
This is a Class A product based on the standard of the Voluntary Control Council for Interference by
Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio
disturbance may arise. When such trouble occurs, the user may be required to take corrective actions.
Copyright Emulex Corporation - All rights reserved - 1998
Tabla de contenidos
Otros manuales de Tarjeta PCI de Emulex
Manuales populares de Tarjeta PCI de otras marcas

Belkin
Belkin F5D7000F Manual de usuario

Pericom
Pericom PI7C7100 Manual de usuario

ADLINK Technology
ADLINK Technology cPCI-3548 Manual de usuario

Digium
Digium TE200 Series Manual de usuario

Allo.com
Allo.com 2nd Gen E1/T1/J1 Manual de usuario

Western Digital
Western Digital FireWire PCI Adapter Manual de usuario