Manual-EMT-HI-Tonearm 10/13
Setting the tracking force (VTF)
Your tonearm features a unique mechanism for coupling the counterweight
to the rear end of the tonearm. A spring-loaded pin connects with the spiral-
groove and allows quick linear positioning as well as precise and backlash-
free adjsutment.
An engraved scale allows setting the vertical tracking force, even if you
don’t have a tonearm scale at hand.
Installing the counterweight
- Hold the counterweight (1) and move it to the rear end of the tonearm (2)
- Move the counterweight horizontally for approcimate setting
- Turn the counterweight clockwise to increase the VTF
- Turn the counterweight anticlockwise to decrease the VTF
Reset the scale
- Turn the counterweight until the tonearm is in fully balanced position
- Hold the main-unit (3) of the counterweight in place
- Turn the scale (4) until the 0-Position is aligned with the marking (5)
Setting the VTF
Turn the counterweight until the wanted value for the VTF is aligned with
the marking (5). The scale shows the value in dg: 10dg = 1g.
Note
The accuracy of the integrated scale is limited to ±0,1g. For more precise
adjustment, please use a separate tonearm scale.