Emist EPIX360 Manual de usuario

EPIX360
TECHNICAL MANUAL
VER. 010621

2
EPIX360 - Technical Manual
©2021 EMist® is a registered trademark of SanoTech 360, LLC. All rights reserved. EMist-00135-20-EPIX360 Technical Manual - 010621
Thank you for choosing the EMist®EPIX360™ Electrostatic Sprayer.
We’ve created an easy-to-use system that combines advanced liquid application technologies with improved
mobility. The result is superior application and enhanced disinfection, as well as a convenient design for users.
We recommend you read through this entire instruction manual before beginning.
Included are assembly, operating, and safety instructions. Following these manufacturer guidelines will help
the system perform at peak eectiveness, extend the life of the product, and ensure operator safety.
Questions?
Each component has been inspected prior to your purchase. However, in the event that there is a problem,
please contact our customer care center at Emist.com.
EPIX360™ Electrostatic Sprayer Technical Manual

3
EPIX360 - Technical Manual
©2021 EMist® is a registered trademark of SanoTech 360, LLC. All rights reserved. EMist-00135-20-EPIX360 Technical Manual - 010621
LIMITED WARRANTY FOR NEW EPIX360™ EQUIPMENT
* Each warranty term begins on the date of product delivery to the purchaser.
* Attachments purchased on the same purchase order as the equipment listed will be covered by the equipment’s warranty terms.
A. GENERAL PROVISIONS: The warranties described below are provided by SanoTech 360, LLC, dba
EMist to the original purchaser of the new EPIX360™ equipment from EMist or authorized reseller, with proof
of purchase which may be accomplished by registering the product at emist.com/warranty/. Under these
warranties, EMist will repair or replace, at its option, any covered part which is found to be defective in material
or workmanship during the applicable warranty term. Warranty service must be performed by EMist, or its
authorized service providers, which will use only new or refurbished parts or components furnished by EMist.
Warranty service will be performed without charge to the purchaser for parts and labor. The purchaser will be
responsible for any service call, and/or transportation of product to and from EMist, for any premium charged
for overtime labor requested by the purchaser, and for any source and/or maintenance not directly related to
any defect covered under the warranties below.
B. WHAT IS WARRANTED: All parts of any new EMist equipment are warranted for the number of months or
days specied below.
C. WHAT IS NOT WARRANTED (EMist IS NOT RESPONSIBLE FOR THE FOLLOWING): (1) Any
equipment that has been altered or modied in a way not approved by EMist including, but not limited to, EMist
specications, and such alteration or modication caused the defect or damage; (2) Depreciation or damage
caused by normal wear, lack of reasonable and proper maintenance, failure to follow operating instructions,
misuse, lack of proper protection during storage, or accident; (3) Normal maintenance parts and service.
D. SECURING WARRANTY SERVICE: To secure warranty service, the purchaser must (1) Report the product
defect to EMist and request repair within the applicable warranty term; (2) Present evidence of the warranty
start date (proof of purchase); (3) Make the equipment available to EMist within a reasonable period of time.
E. NO RESELLER WARRANTY: The reseller makes no warranty of its own and the reseller has no authority to
make any representation or promise on behalf of EMist, or to modify the terms or limitations of this warranty in any
way.
F. LIMITATION ON IMPLIED WARRANTIES: Any implied warranties granted to the original purchaser of new
EPIX360™ Equipment under law shall be limited to the limited warranty time frame set forth herein.
If further information is desired, contact EMist at Emist.com.
EPIX360™ Equipment Warranty Terms*
1. FG.2000 EPIX360 Handheld Sprayer 12 Months or 365 Days
2. EP36BTLI20 EPIX360 Handheld Battery Lithium-Ion 2020 3 Months or 90 Days
3. EP36CHLI20 EPIX360 Handheld Charger Lithium-Ion 2020 3 Months or 90 Days
4. EP36TK0820 EPIX360 Tank 8 oz. 2020 3 Months or 90 Days
5. EP36TKL820 EPIX360 Tank 8 oz. Disposable Liner 2020 No Warranty
6. EP36HCFC20 EPIX360 Hard Case with Custom Foam 2020 3 Months or 90 Days
7. EP36CHEU20 EPIX360 Handheld European Charger Lithium-Ion 2020 3 Months or 90 Days
8. EP36TCA820 EPIX360 Handheld Tank Cap Assembly 1 Month or 30 Days
9. EP36TCC820 EPIX360 Handheld Tank Cap Cover 1 Month or 30 Days
10. EP36NZT820 EPIX360 Handheld Nozzle Tip 3 Months or 90 Days

4
EPIX360 - Technical Manual
©2021 EMist® is a registered trademark of SanoTech 360, LLC. All rights reserved. EMist-00135-20-EPIX360 Technical Manual - 010621
Technical Schematics
Section A - Internal Mechanics Schematics Illustration Page 5
Section B - Schematics Itemized Parts List Page 6
Troubleshooting the Backpack Assembly Area
Section 1 - Battery Page 7-8
Section 2 - Disassembly Procedures Page 8-10
Section 3 - Main Customer Quality Issues Page 10-12
Section 4 - Tank Liner Procedures Page 13
Section 5 - Before Reassembly Page 13-14
Section 6 - System Reassembly Page 14-15
Component Installation TABLE OF CONTENTS

5
EPIX360 - Technical Manual
©2021 EMist® is a registered trademark of SanoTech 360, LLC. All rights reserved. EMist-00135-20-EPIX360 Technical Manual - 010621
System Pieces and Part Numbers
EPIX360 Internal Mechanics Technical Schematic
Section
a
Itemized list on next sheet

6
EPIX360 - Technical Manual
©2021 EMist® is a registered trademark of SanoTech 360, LLC. All rights reserved. EMist-00135-20-EPIX360 Technical Manual - 010621
Item
Number
Part
Number
Quantity Description
System Pieces and Part Numbers
EPIX360 Body and Accessories Technical Schematic
Section
b
1 HW.00.060 1 2-56 Stainless Steel Hex Nut
2 HW.00.058 1 2-56 x 5/32” Stainless Steel Pan Head Screw
3 HW.00.253 2 11MM x 7MM x 2MM Viton O-Ring
4 HW.00.055 2 2.5MM x 7MM Stainless Steel Plastic Screw
5 HW.00.051 6 3MM x 12MM Stainless Steel Plastic Screw
6
7 HW.00.053 4 3MM x 16MM Stainless Steel Plastic Screw
8 HW.00.054 1 3MM x 20MM Stainless Steel Plastic Screw
9
10
11 HW.00.062 2 4MM Stainless Steel Star Washer
12 HW.00.059 1 10-32 x 1/4” Stainless Steel Pan Head Screw with Viton O-Ring
13 HW.03.038 1 Tank Cap
14 FG.2009 1 14.4 Volt Battery
15 MD.03.039 1 Tank Cap Washer
16 FG.2012 1 HH 8oz Tank Liners
17 MD.03.044 1 Leanback Pump Manifold
18 MD.03.041 1 Battery Terminal
19 MD.03.042 4 Battery Contact
20
21
22 MD.03.043 1 Inline Fan Housing
23 MD.03.045 1 Tank Lock
24 HW.03.069 1 Tank Base
25
26 MD.03.047 1 Nozzle Charging Ring Mount
27 LQ.01.101-A 1 Micro Pump
28 EL.02.057 Fan Motor
29 MD.03.048 Fan
30 HW.00.254 1 0.145ID x 0.070CS Viton O-Ring
31 MD.03.046 1 Nozzle Assembly Mounting
32 MD.03.050 1 Nozzle Extension
33 MD.03.049 1 Nozzle
34
35 MD.03.070 1 Tank Check Valve Release
36 MD.03.051 1 Riser
37
38 MD.03.067 1 Stainless Steel Spray Terminal
39 MD.03.063 1 Spray Tip
40
41
42 MD.03.066 1 Stainless Steel Charging Ring
43 MD.03.094 1 HH 8oz Tank
44 MD.03.054 1 Tank Cap
45 MD.03.053 1 Tank Cap Cover
46
47 MD.03.065 1 Pump Adaptor
48 MD.03.059 1 Tubing Retainer
49 MD.03.068 1 Valve Plate Spring Seat
50
51 MD.03.056 1 Left & Right Handle Conductive Grips
52 MD.03.055 1 Left & Right Wand Halves
53 MD.03.057 1 Wedge Cap Fan Cover
54 MD.03.058 1 Silicone Protective Cover
55

7
EPIX360 - Technical Manual
©2021 EMist® is a registered trademark of SanoTech 360, LLC. All rights reserved. EMist-00135-20-EPIX360 Technical Manual - 010621
Battery Charger Instructions
Battery
Section
1a
Battery Charger Instructions
Battery
Section
1b
(Overturned battery)
Align the battery slots to the
charger receptors.
Be Advised! No other brand of battery should be used for the
EPIX360, only the bateries supplied with the unit kit (see photo).
If any other battery is used and damage occurs to the EPIX360
unit, this will void the warranty.
Battery Charger Instructions & Guideline:
1. While charging battery, the “RED” indicator light will slowly
strobe “ON” and “OFF” (normal operation.)
2. If “RED” Indicator light stays on, this means the battery is fully
charged. If the “RED” indicator light blinks fast, this indicates the
battery is not secure to the charger.
Slide battery onto outline
conguration and secure in
place.
Battery
Battery Charger

8
EPIX360 - Technical Manual
©2021 EMist® is a registered trademark of SanoTech 360, LLC. All rights reserved. EMist-00135-20-EPIX360 Technical Manual - 010621
Battery Installation Instructions
Battery
Section
1c
Removal of EPIX360 Frame Silicone Sleeve (Pt. #MD.03.058).
Disassembly Procedures
Section
2a
Align battery along
slots of the battery
(outlined above) on
the EPIX360 unit.
Slide unit or slide battery until
you hear a “click.”
To remove battery: Press down on release
tab, then slide battery out from unit.
Battery is secured in
place.
BE ADVISED -
When battery tester
is pressed and the
center “GREEN” light
is not “ON” - battery is
defective and needs to
be replaced.

9
EPIX360 - Technical Manual
©2021 EMist® is a registered trademark of SanoTech 360, LLC. All rights reserved. EMist-00135-20-EPIX360 Technical Manual - 010621
Removal of EPIX360 Frame Silicone Sleeve (Pt. #MD.03.058).
Disassembly Procedure
Section
2b
Disassembly Instructions for the Shell Separation EPIX360 Unit
Disassembly Procedure
Section
2c
Take a razor or box
cutter, cut the serial
number label along the
split were the 2 halves
of the pastic body
meet.
Remove all (9) T10 Torx Star
Screws (Pt. #HW.00.053) from
main EPIX360 unit.
Remove (2) T8 Torx
Star Screws (Pt.
#HW.00.253) from
main EPIX360 unit
front nozzle assembly.
a.) Start from the rear of the unit, gently
pull the sleeve away from the frame.
b.) Peel the sleeve towards the front of
the frame of the unit, then remove.
b.)
b.)
a.)
a.)
b.)

10
EPIX360 - Technical Manual
©2021 EMist® is a registered trademark of SanoTech 360, LLC. All rights reserved. EMist-00135-20-EPIX360 Technical Manual - 010621
Disassembly Procedure
Section
2d
Overview
Main Customer Quality Issues
Section
3a
Removing the Rear Fan Cover - Continued
Remove (2) T10 Torx Star
Screws from main EPIX360
unit front nozzle assembly.
1.) The trigger switch (Pt.# SA.2000.4)
2.) The tank check valve release (female valve release-tank cap - (Pt. #SA.2011.1) & (male valve)
One can separate both halves
of the EPIX360 unit.
Male check valve release Female check valve release-tank cap Pt. #SA.2011.1
Otros manuales para EPIX360
5
Este manual sirve para los siguientes modelos
1
Tabla de contenidos
Otros manuales de Pistola pulverizadora de pintura de Emist

Emist
Emist EM360 Manual de usuario

Emist
Emist EM360 Manual de usuario

Emist
Emist EPIX360 Manual de usuario

Emist
Emist EM360RC Manual de usuario

Emist
Emist EM360 Manual de usuario

Emist
Emist EPIX360 Manual de usuario

Emist
Emist EM360 Manual de usuario

Emist
Emist EPIX360 Manual de usuario

Emist
Emist EM360 Manual de usuario

Emist
Emist Tru Electrostatic EX-7000 Manual de usuario