Eminent EM8622 Manual de usuario

EM8622
Wireless Control Panel

2 | ENGLISH
EM8622 - Wireless Control Panel
Table of contents
1.0 Introduction ........................................................................................................... 3
1.1 Packing contents ............................................................................................... 3
1.2 Control panel front ............................................................................................. 3
1.3 Control panel inside ........................................................................................... 4
2.0 Installation ............................................................................................................. 4
3.0 Usage .................................................................................................................... 5
3.1 Arm the alarm system ........................................................................................ 5
3.2 Disarm the alarm system ................................................................................... 6
3.2.1 Using control panel to disarm ..................................................................... 6
3.2.2 Using RFID Tag to disarm .......................................................................... 7
3.2.3 Home Mode ................................................................................................ 7
3.2.4 Emergency Call .......................................................................................... 8
3.2.5 Mute Mode ................................................................................................. 8
4.0 Connect to the alarm system ................................................................................. 9
5.0 Connect RFID Tag to control panel ........................................................................ 9
6.0 Settings ............................................................................................................... 11
6.1 Enter Setup-state ............................................................................................. 11
6.2 Delay Arm........................................................................................................ 11
6.3 SOS Speed dial ............................................................................................... 12
6.3.1 Disable SOS code .....................................................................................13
6.3.2 Enable SOS code ......................................................................................13
6.4 Keyboard tone ................................................................................................. 14
6.4.1 Disable keyboard tone ...............................................................................14
6.4.2 Enable keyboard tone ................................................................................14
6.5 Disarm system by RFID tag ............................................................................. 15
6.5.1 Disable disarming by RFID tag ..................................................................15
6.5.2 Enable disarming by RFID tag ...................................................................15
6.5.3 Disarming silently by RFID tag ...................................................................16
6.6 Power saving mode ......................................................................................... 16
6.6.1 Enable power savig mode..........................................................................17
6.6.2 Disable power saving mode .......................................................................17
6.7 Change user code ........................................................................................... 18
6.8 Change admin code ........................................................................................ 18
6.9 Reset the control panel .................................................................................... 19
7.0 Frequently Asked Questions and other related information .................................. 19
8.0 Service and support ............................................................................................. 20
9.0 Warning and points of attention ........................................................................... 21
10.0 Warranty conditions ........................................................................................... 22
11.0 Declaration of Conformity .................................................................................. 23

3 | ENGLISH
1.0 Introduction
Congratulations with the purchase of this high-quality Eminent product! This product
has undergone extensive testing by Eminent’s technical experts. Should you
experience any problems with this product, you are covered by a five-year Eminent
warranty. Please keep this manual and the receipt in a safe place.
Register your product now on www.eminent-online.com and receive product updates!
1.1 Packing contents
The following parts need to be present in the packing:
EM8622 Wireless Control Panel
Manual
3pcs AAA batteries
External connection cable
Screws and plugs
1.2 Control panel front
Led indicator
RFID tag reader
Arm button
Disarm button
Home mode button
SOS button
Wake-up button

4 | ENGLISH
1.3 Control panel inside
2.0 Installation
Install the batteries and mount the control panel on the door frame or the wall before
use.
Battery contact, please check
positive and negative
terminals
Battery compartment
Tamper switch
Wired cable connection
Red wire = + 12V
Black wire = - GND

5 | ENGLISH
1) Remove the screw and open the case
2) Install the batteries according to the positive and negative signs (Remove the
insulating strip before the first use)
3) Mount the backcover on the door frame or wall
4) Close the case and replace the screw
Note : Opening the cover will trigger the tamper switch ! You can disarm it by entering
the admin code 123456 followed by [#].
Note : The default admin code is : 123456. See chapter “Change Admin Code” to
change it.
Note : The default user code is : 1234. See chapter “Change User Code” to change it.
3.0 Usage
The control panel can be used as a remote control. User code or admin code should
be input before the operation of Arm, Disarm, Home Mode and Mute Mode.
3.1 Arm the alarm system
Input user code or admin code, and press [Arm] key. The LED indicator
flashes once and the control panel beeps once and sends Arm command to
the alarm system.
When the alarm panel receives the signal, the siren will beep once and the
Arm indicator will light on. The alarm system enters armed state.

6 | ENGLISH
If there is an intrusion the alarm system will be triggered, the siren will hoot
and the alarm system will send an SMS and auto dial to pre-stored phone
numbers to notify users.
Note : When an entry delay is set, the external control panel will NOT warn you with
an audio signal when a sensor is triggered. Only the alarm system itself will give an
audio signal !
3.2 Disarm the alarm system
Users can disarm the alarm system by using the control panel or by using RFID tags.
3.2.1 Using control panel to disarm
Input user code or admin code, and press the [Disarm] key. The LED indicator
flashes once and the control panel beeps once, and sends Disarm command to the
alarm system.
When the alarm panel receives the signal, the siren will beep twice and the Disarm
indicator will light. The alarm system enters disarmed state. In this state the sensors
being triggered will not cause an alarm.

7 | ENGLISH
3.2.2 Using RFID Tag to disarm
If direct disarm by RFID tag is disabled (this is the default power saving mode when
using batteries), user needs to press [*] to wake up the control panel and then put
RFID tag close to the reader to disarm the alarm system..
When the power saving function is disabled, user can put the RFID tag directly close to
the control panel to disarm the alarm system.
3.2.3 Home Mode
Input user code or admin code and press [Home Mode] key, the LED indicator flashes
once and the control panel beeps once and sends Home Mode command to the alarm
system.
When the alarm panel receives the signal, the siren will beep once and the Home
Mode indicator will light, the alarm system enters Home Mode state.
All the sensors in other zones are armed to prevent the intruder except that the motion
detector in Home Mode Zone is disarmed, so that people can move freely at home.
Note : Check manual of the alarm system for installing sensors in home mode.

8 | ENGLISH
3.2.4 Emergency Call
When the control panel is in SOS Speed Dial mode, user just holds the [SOS] key
for 3 seconds, the LED indicator flashes once, the control panel beeps once, and the
alarm system alarms immediately.
When the control panel is not in SOS Speed Dial mode, user needs to input user
code or admin code before holding the [SOS] key for 3 seconds to send an alarm.
3.2.5 Mute Mode
Mute mode means that the LED indicators of the control panel flash, but the siren
does not beep to avoid disturbing the neighbourhood.
Input user code or admin code, and hold any key of [Arm] [Disarm] [Home Mode] for
2 seconds. The LED indicator flashes once, the control panel beeps once and sends
corresponding command to the alarm system.
When the alarm panel receives the signal, the LED
indicator lights on or off, but the siren does not beep.

9 | ENGLISH
4.0 Connect to the alarm system
Note : The default admin code is : 123456. See chapter “Change Admin Code” to
change it.
Note : The default user code is : 1234. See chapter “Change User Code” to change it.
Make sure the alarm system is in connection state (press code on alarm system and
press the memo button).
Input the admin code on the control panel and press the Arm, Disarm or Home mode
button.
When the control panel is connected successful the alarm system will give one beep.
5.0 Connect RFID Tag to control panel
Note : The default admin code is : 123456
1. Input the admin code followed by the [#] button. ( a long beep is heard)
2. Immediatly after step one, press the 9 button. One beep is heard an the LED
indicator will be on for about 2 seconds. The control panel is in learning state.
During the time the LED is on, you can connect the RFID tag to the control panel.

10 | ENGLISH
3. Put the RFID tag close to the RFID reader. If one beep is heard the connecting is
successful. When 2 beeps are heard, the RFID tag was already connected to the
control panel.
To remove all connected RFID tags, input the admin code followed by the # button.
Press and hold down the 9 button for six seconds. All RFID tags are cleared after one
beep is heard.
Note : you can connect up to 50 RFID tags to the EM8622.