Emerson RXi HMI GFK-3233A Manual de usuario

Instructions to printer
DO NOT PRINT THIS PAGE
This document is intended to be printed in coloras a
5.5 (width) x 6.5 inch (length) booklet with stapled binding.
Use high-quality, glossy 20lb (75 g/m²) paper.
Print double-sided. Fold sheet of 8.5” x 11” in two, trim length
and staple spine.
European version can use A4 in place of 8.5” x 11”.

RXi HMI Quick Start Guide
GFK-3233A
Jan 2022

iRXI Basic Quick Start Guide GFK-3233A

ii RXI Basic Quick Start Guide GFK-3233A
Contents
Contents ................................................................................................ii
Regulatory Information ...........................................................................1
Intended Use.................................................................................................. 1
Connecting Your Device ..........................................................................2
RXi HMI Connectors........................................................................................ 2
Step 1: Connect the Input Power (24V DC-in) ................................................. 2
Step 2: Connect Your Display .......................................................................... 3
Step 3: Connect Your Network Devices ........................................................... 4
Step 4: Connect Your Mouse and Keyboard..................................................... 4
Step 5: Connect Your Serial Devices (UART) .................................................... 5
RXi HMI Initial Start Up ............................................................................6
RXi HMI Windows Activation..................................................................12
Additional Information ..........................................................................15
General Contact Information ........................................................................ 16

1RXI Basic Quick Start Guide GFK-3233A
Regulatory Information
The FCC requires the following note to be published according to the FCC
guidelines:
NOTE: This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause
undesired operation.
CAUTION
Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
Industry Canada requires the following to be published: CAN ICES-3
(A)/NMB-3 (A).
Intended Use
The RXi HMI is intended for use in industrial environments only. Adherence
to supplied documentation is part of the intended use. Installation,
commissioning, and maintenance shall be carried out by qualified
personnel. For more information, please consult GFK-3163, RXi Installation
and Maintenance Requirements.

2RXI Basic Quick Start Guide GFK-3233A
Connecting Your Device
The rear panel I/O port arrangement consists of the following:
RXi HMI Connectors
Figure 1: Rear Panel Arrangement
Step 1: Connect the Input Power
(24V DC-in)
To connect to power, follow these steps:
1. Verify that the power cable is not
energized.
2. Loosen the screw clamps on the
mating power connector.
3. Strip the insulation from the power
cables.
4. Secure the power cable to the mating
connector, noting polarity, and
tighten the screw clamps. The torque
for the attaching screws is 0.3 Nm (2.26 in-lb).

3RXI Basic Quick Start Guide GFK-3233A
5. Apply dc power to the unit. During normal startup and operation,
the LED status indicator displays as follows:
•Solid amber while the RXi HMI unit is starting up
•Solid green during normal operation
Be sure to connect a DC power cord to this 3-pin power connector. Using a
voltage out of the range may fail to boot the system or cause damage to the
system board. The recommended connector is Dinkle EC350VM-03P.
Step 2: Connect Your Display
The RXi HMI uses a DisplayPort to connect to a display device such as a
computer monitor. The DisplayPort connection will be used to transmit
both audio and video. If additional configuration is required, visit the
Chipset menu in the device BIOS on startup.
Operation Status LEDs (Screen)
RXi HMI has a tri-color LED built into the screen that provides visual indication
of the operation status.
LED State
System State
Amber, Solid
Operating system starting
Green, Solid
Normal operating state
Green, Blinking
Backlight off
Red, Blinking
Backlight failure
Off
Power not applied to the unit

4RXI Basic Quick Start Guide GFK-3233A
Step 3: Connect Your Network Devices
The RXi HMI has Four Base-T Ethernet Ports. Use the LAN ports to connect to
a local area network through a network hub or router. If additional
configuration is required, visit the Wakeup Configuration menu in the device
BIOS on startup.
Ethernet Port Operation LEDs
LED
LED State
Operating State
Speed
Yellow, ON
10/100/1000
Link
Activity
Green, ON
Link Status
Step 4: Connect Your Mouse and Keyboard
The RXi HMI features two USB 2.0 (Type-A) ports for mouse and keyboard.
(There are also two USB 3.0 (Type-A) ports for external storage devices.) If
configure the device to wake on keyboard/mouse function visit the Wakeup
Configuration menu in the device BIOS on startup.

5RXI Basic Quick Start Guide GFK-3233A
Step 5: Connect Your Serial Devices (UART)
The RXi HMI features two serial port connections. Connect these devices
using the pin-out configuration seen in
Table 1: Serial Pin-Out Configuration
Serial Connection
Pin
Function
RS232
1
TXD
2
RXD
3
RTS
4
CTS
5
GND
RS485
6
TX+
7
TX-
8
RX+
9
RX-
10
GND

6RXI Basic Quick Start Guide GFK-3233A
RXi HMI Initial Start Up
1. Select the region and then click Yes.
Figure 2: Region Selection
2. Select the keyboard layout desired and click Yes. If desired, the next
screen will prompt the user for a second keyboard layout.
Figure 3: Keyboard Layout Selection
Tabla de contenidos