M1XRFTWM Installation Manual Page 9
Enrolling Sensors from the M1 Keypad Installer Programming (additional details on following pages)
NOTE: The M1XRFTWM must be enrolled on the data bus at address 2.
1. From M1 Keypad Installer Programming scroll or navigate to Menu: 14-Wireless Setup
2. Press right arrow and scroll up to Sub-Menu: 3:Learn SelbPrgrWirelessTransmtr
3. Press right arrow WZoneandsearchofscrolltotherstavailable(unused)locationdisplayingTransmitrToLrn. An existing or
already enrolled location will display Enrolled followed by a 6 digit TXID number of the enrolled sensor.
4. AfterndinganavailablewirelesszonelocationpresstherightarrowtoLrn (Enroll) a sensor into this location.
5. The keypad will display Push Transmitter Button and the M1G will announce: "Press transmitter button for zone __". On
successfulenrollmentthekeypadwillchimeandtheTXIDwillbrieydisplay.TheM1Gwillannounce:"Zone __ Enrollment".
The Rapid-Enroll feature will advance to the next available wireless zone in sequence and wait for another sensor to be enrolled.
The M1G will announce: "Press transmitter button for zone __". The Rapid-Enroll may be exited by pressing the ELK key.
ENROLL METHOD 1 -
A. Insert Battery in the Sensor while M1 is displaying "Push Transmitter Button". If battery is already installed then remove
it and wait 5 seconds before re-inserting.
B. UponsuccessfulenrollmenttheKeypadwillchimeandbrieydisplaythe6digitTXIDcodeoftheSensor.
- If enrollment FAILS the TXID will not display. If that happens then remove the battery, wait 5 seconds, then re-insert.
ENROLL METHOD 2 - For Sensors with Multiple Zone Inputs. The enrollment must be repeated for each additional Zone Input. The
TXID will be the same for each. We strongly recommend enrolling the additional zone(s) in sequence with the 1st.
A. For the internal reed switch Zone (LP2) insert the Battery into the Sensor while M1 is displaying Push Transmitter Button.
B. UponsuccessfulenrollmenttheKeypadwillchimeandbrieydisplaythe6digitTXIDcodeoftheSensor.
- If enrollment FAILS the TXID will not display. If that happens then remove the battery, wait 5 seconds, then re-insert.
The Rapid-Enroll feature will auto advance to the next wireless zone.
C. To enroll the next Zone (marked LP1) on this sensor REMOVE the Battery and wait 5 seconds. Then re-insert Battery into
the sensor. Repeat this step to enroll the next Zone (marked LP3).
D. The Loop # must be progammed uniquely for each input since the TXID will be the same for all 3 available wireless zones.
ENROLL METHOD 3 - KEYCHAIN REMOTES †
A. PRESS and HOLD button 1 or button 2 while M1 is displaying Push Transmitter Button.
B. UponsuccessfulenrollmenttheKeypadwillchimeandbrieydisplaythe6digitTXIDcodeoftheSensor.
- If enrollment FAILS the TXID will not display. If that happens then remove the battery, wait 5 seconds, then re-insert.
NOTE: If the M1 Lrn (Enroll) function times out or is manually exited then It may be necessary to restart from Step 1
6. To end Rapid-Enroll once all wireless zones (sensors) have been enrolled, press the ELK key one time.
7. Loop # - Refer to the "Elk 6000 Series Wireless Sensors" chart for more information on the loop setting of each sensor. For single
internal reed sensors the Loop # setting will be 2. It is VERY IMPORTANT to follow the directions outlined in the referenced
chart and set the Loop # correctly. To set the Loop # scroll up or down to the desired M1 wireless zone and press the left arrow.
The screen will display a 9 digit number (the TXID in decimal) followed by Loop=. Press the right arrow and move cursor over to
Loop=.
8. Program the Zone Def. using Menu 5: Zone Denitions.
Enrolling Sensors from the ElkRP Software
1. LaunchElkRPandopenthedesiredCustomerAccountle.
2. IfnowirelesszonescurrentlyexistintheM1youwillrstneedtocreateagroupof16wirelesszones.Inthefolderscolumnright
click on Zones (Inputs), then click New Wireless Zones. Select Group 2. NOTE:TherstM1XRFTWMmustbeenrolledatdata
busaddress2,thereforetherstwirelesszonewillalwaysbeZone17whichresidesinGroup2.Additionalgroupsof16zones
may be added as required. It a hardwired zone expander is occupying address 2 it will have to be relocated to another address
so that the M1XRFTWM can be at address 2. Up to 3 additional M1XRFTWM Transceivers may added for expanded coverage.
If so, they must be enrolled at addresses 3, 4, and 5 respectively. If a large quantity of wireless zones is expected, avoid enrolling
hardwired expanders in data bus addresses below 10. This will allow for the maximum of 144 wireless zones.
3. ProgramtheZoneDenition,Name,Type,anddesiredoptionsbyclickingon:Wireless Group(thegroupjustadded).Thenselect
eachzoneoneatatimetoprogram.Zonesdenitionsmaybeassignedbeforeoraftersensorenrollment.
4. To enroll the sensors click on: Wireless Setup from the folders column.
A. Click the > Transmitters tab, then double click a zone.
B. Place a check mark in the Enabled box.
C. Set Supervision type as either: 0=Non Supervised (Keyfobs), 1=Normal “Burg” Supervision, or 2=Fire Supervision
D. TXID # - type in the Sensor TXID printed on the label on the inside and outside of the sensor.
E. LOOP # - Refer to step 7 above and the "Elk 6000 Series Wireless Sensors" for more information.
F. Click Save. Repeat the entire step 4 for each additional Wireless Sensor.
IMPORTANT! For sensors with multiple zone inputs the enrollment must be repeated for each additional Zone Input and the TXID will be
the same for each. We strongly recommend enrolling the additional zone(s) in sequence with the 1st. The Loop # must be programmed
correctly to identify which zone input belongs with which wireless zone.
'Quick Step' Enrollment of Elk 6000 Series Sensors
† Not evaluated by UL