elero sonneboy Guía

»sonneboy«
"The intelligent weather monitor”
No programming, no adjusting.
Install, connect, ready to go.
GB-1 109.55012/0801
Installation and
connection instructions

Contents
Page
Explanation of display and keys.............................................................................. 3
General ...........................................................................................................................
Technical data ..............................................................................................................
Assembly and connection......................................................................................... 5–8
Fitting accessories....................................................................................................... 9–10
Operation........................................................................................................................ 11
Setting ranges............................................................................................................... 12
Explanation of Prog key ............................................................................................. 13
Programming................................................................................................................. 13–1
Changing light values ................................................................................................. 13
Changing temperature value .................................................................................... 13–1
Changing wind value................................................................................................... 13–1
Changing pulse duration ........................................................................................... 13–1
Changing delay times ................................................................................................. 13–1
Menu selection ............................................................................................................. 15
Programming protection ............................................................................................ 15
Programming menus................................................................................................... 15
View program................................................................................................................ 16
Delete program............................................................................................................. 16
Programming intermediate position/turning point ............................................. 16
Deleting intermediate position/turning point........................................................ 17
Automatic test for light value..................................................................................... 17
Troubleshooting ........................................................................................................... 18
2

3
Explanation of display and keys
No. Function
1[UP ▲] command key
a) manual „Up“
b) setting figures in
programming mode (plus)
2[DOWN ▼] command key
a) manual „Down“
b) setting figures in
programming mode (minus)
3[Prog] key
Calling up and interrupting
program
4[ENTER] key
Confirmation of programming
(in programming mode)
5[AUTO] key
Automatic/manual mode
6Unassigned key
7Display
Automatic On/Off
No. Function
8Display for rain
9Display for top end position
(TEP)
0Up/Down command key
ßDisplay, brightness value
exceeded
“[C] key (in conjunction with
[DOWN ▼] key) to set
thresholds and times
in basic program
„Display, set wind
value exceeded
”[Free] key
programming protection
¿Display for temperature
value (appears only if
temperature control is
active)
¸Display for brightness value
qDisplay for wind value
Auto Prog
ESO
Menu
Thresholds
Times
Enter
Auto
Free

1. General
The microprocessor-controlled elero sonneboy with rain sensor
input is a compact control unit for electric sunshade systems like
venetian blinds, awnings and blackout blinds.
The automatic control system controls the system automatically as
a function of light intensity (sunshine), wind and rain (snow).
There is also the option of controlling shade as a function of
temperature using the integrated temperature sensor (located on
the board).
This is an especially useful facility in conservatories for saving
heating costs. The wind monitor takes precedence over the light
sensor and the rain monitor and also in automatic and manual
operation so that the sunshade system is reliably protected from
damage. The rain monitor takes precedence only over the light
sensor and only works in automatic mode. Once the wind monitor
has responded, the sunshade system cannot be actuated for at
least the set pulse duration (30 sec.- 3 min.).
The "sonneboy has a basic program in which light value,
temperature, wind value, pulse duration and delay time are all
pre-programmed, i.e. the automatic sunshade system can be
started without being programmed.
If you would like to set different values for brightness, temperature,
wind, pulse duration or delay time, proceed as per Section 8.
2. Technical data
●Voltage: 230 V AC
●Frequency: 50 Hz
●Power draw: ,5 mA
●Switching current: 3 A, cos ϕ= 0,6
●Rupturing capacity: 690 VA
●Output: 2 relays (make contacts) potential-free
●Input: light sensor, wind monitor, rain monitor and
external switch
●Pulse duration: 30 sec. to 3 min. (adjustable)
●Ambient temperature: –5 °C to + 50 °C
●Type of protection: IP 20
●Installation location: Dry areas (do not fit outdoors)
●Basic program: light value for extend 5, for retract ,
temperature "- -", wind value 3, pulse
duration 3 min. and delay time for extend 5,
for retract 10 are pre-programmed.
These values can also be changed

3. Assembly and connection
Work on the mains may be performed only by authorised
specialists
When connecting the wires for mains and protective low voltage
(sensors, external switches), VDE 0100 Part 10 and the assembly
instructions should be observed.
●Switch off mains power
●Connect as per wiring diagram
●Fit light sensor, wind monitor and rain monitor as per Section ,
fit following the relevant instructions
●Clip terminal cover onto (8-pin) connecting terminal
●The power unit is fixed in position using 2 expanding binders or
using mounting screws
●Clip cover onto control panel (see series of diagrams below)
●Plug on control panel
●Switch on power
●Set manual mode using "Auto On/Off” key. "Manual” appears on
the display (manual mode is set on delivery).
●Using the vor bkey, check direction of rotation of the motors.
Important Key vsunshade system must retract
Key bsunshade system must extend
●If the direction of rotation of the motors does not agree with the
vand bsymbols on the control panel, switch off power and
change over wires a vand bterminals of the power unit, then
switch power back on.
5
Series of diagrams for assembly (representation applies to any
model)
1: Cover
2: Control panel
3: Adapter frame
.1: Frame
.2: Bearing ring
5: Power unit
6: Terminal cover
7.1: Branch box l60, No. 13 701.5101
7.2: Surface socket, No. 2 8 3.0103 or No. 2 752.0001
Parts .2 and 7.2 replace parts .1 and 7.1 in the case of surface mounting.
Always put parts 1 and 2 together first when assembling.

6
Important notes:
When connecting the light sensor, check the connection is
correct (1-1, 3-3)!
If the light sensor is connected with incorrect polarity, brightness
value 12 appears in the display.
The connection wires to the light sensor, wind monitor and rain
monitor must always be executed as a shielded cable;
either a separate 2-wire line or -wire shared line, e.g. Siemens
LSYCY MSR control line or JY-ST-Y 2 x 2 x 0.6 telecommunicati-
ons line
●Only 1 wind monitor per "sonneboy” may be connected between
terminals 2 and 3.
●A second light sensor can be connected between terminals
and 6 to increase the angle of incidence. No account need be
taken of the angle of incidence of the sunlight (for connection,
see Page 8).
●If it is not possible to connect a second light sensor between
terminals and 6 because there are insufficient wires, it is also
possible to connect the second light sensor in parallel with the
first one between terminals 1 and 3.
The light sensors may not be fitted in the same angle of incidence
of sunlight, however, they must be offset by at least 60° (see dia-
gram below). Furthermore, the light value needs to be set at least
2-3 levels higher than in the basic programme.
Light
sensor

7
Wiring diagram
Connection max. 1 motor
Do not connect with power switched on!
Attention: you must observe the correct polarity when connecting
the light sensor
Additional control units are required to connect several motors or
switching points.
To do this, please ask for elero control documentation.
Note:
When a temperature level is set, the light sensor only becomes
active once the set level has been exceeded.
A second switching point (individual switch) can be connected for
individual operation. This is given equal priority to the functions of
the [UP] and [DOWN] keys on the control panel and is thus also
only active in manual mode (for connection, see Page 8).
UP
DOWN
blue
green/yellow
Mains
230 V/50 Hz
light
sensor wind
monitor
red
white
black
white

8
Connecting a switch
Attention: switch only works in "manual” mode.
Connecting a second light sensor
(to increase angle of incidence)
Note: either a switch or a second light sensor can be connected.
It is not possible to connect both at once.
Connecting a rain monitor
The rain monitor retracts the system if it rains (v).
White
red
Mains
230 V/50 Hz
vb
Switch

9
4. Fitting accessories
Light sensor and wind monitor combined
●Fit light sensor and wind monitor vertically, close to the awning
(see Fig.) where sun shines and not in the lee of the wind.
Ensure that no shadows (e.g. from a tower or masts) and no
reflections fall on the light sensor.
●Connect as per wiring diagram (see Page 7).
●Clip on cover and/or unscrew (execution Aero).
Wind monitor
●Fit wind monitor close to the awning, not in the lee of the wind.
●Check correctly positioned (see Fig.).
●Connect as per wiring diagram (see Page 7).
●Clip on cover.
Aero

10
Light sensor
●Attach light sensor vertically (cable inlet underneath) above the
awning with two screws (max. diameter ) in an area where sun
shines.
Ensure that no shadows (e.g. from a tower or masts) and no
reflections fall on the light sensor.
●Connect as per wiring diagram (see Page 7/8).
●Clip on hood.
Note: functions only in automatic mode
Rain monitor
●Fit rain monitor vertically (cable inlet underneath) above the
sunshade system (unprotected).
●Connect as per wiring diagram (in cover): make contact /6
(see Page 8).
●Screw on cover.
Note: functions only in automatic mode
Tabla de contenidos
Manuales populares de Estación meteorológica de otras marcas

National Geographic
National Geographic VA Colour RC Manual de usuario

Renkforce
Renkforce 1208067 Manual de usuario

Levenhuk
Levenhuk Discovery Report WA40 Manual de usuario

Instant Transmission
Instant Transmission MA 10410 Manual de usuario

Lutron Electronics
Lutron Electronics PHB-318 Manual de usuario

WAREMA
WAREMA EWFS Weather station eco Manual de usuario