2.3. Preparation for starting and starting
Dehumidifier has button SPEED placed on the control panel ( picture 1/12 ). It enables
to choose speed of flowing air. (You can choose one of two speeds. )
Regulator of humidity – humidistat is another operating element. Humidity regulator
provides switching off or switching on of compressor and it keeps the constant humidity of
air.
Humidistat is adjust by button HUMIDITY (picture 1/11 ). You choose required
humidity of air by pressing button. The pilot lamp indicates selected humidity, which is
placed at the top part of control panel ( picture 1/7 ).
You adjust by this way required humidity and dehumidifier will switch on and switch off
automatically to keep required humidity. Sometimes it takes several days or weeks than
humidity decreases to required humidity.
2.4. Operation
Air contains humidity in the form of steam. It is air humidity. Quantity of humidity, that air
can contain depend on the temperature (when air is warmer, air can contain much more
humidity).
Compressor is part of cooling equipment of dehumidifier, that keeps the surface cool.
Circulating ventilator sucks in wet air and then sucked air flows to the cooling elements, there
is reduced humidity by condensation. Then dehumidified air is blown to the condenser, where
air is dried by warming. Finally dried air is flow back to the room. Dehumidifier is equipped
with automatic defrosting of cooler. Ventilator sucks in the air during the defrosting cycle, but
compressor is switched off automatically.
This system automatically removes ice that can be on the spiral of cooler.
Condensed water is systematically drained by hose connected to the collecting vessels
of dehumidifier. It is necessary to persuade, that hose is right placed.
End of hose must not be sunk into water.
2.5. Breakdown
Before breakdown turn off dehumidifier by button on the control panel (picture 1/10).
Before breakdown for long time you should disconnect the dehumidifier from plug.