8
U.S. and Foreign Patents Pending
Seawater Connection Overview
1. Locate the vessel’s seawater intake pump, strainer, and seacock shut-off valve.
2. Turn OFF ALL seacock shut-off valves in the seawater circuit at or below the
water line. This includes any output seacocks to prevent back siphoning.
3. The ClearCell should be installed after the seawater strainer and pump, and
before any seawater cooled equipment such as air conditioners, chillers, etc.
The ClearCell should be installed at or below the water line.
4. The optional CLEARLINE treated strainer return line should be connected after
the ClearCell Flow Sensor output and before the strainer and after the seacock.
Installation Overview 8
Air Conditioner
Thru-hull
Intake
Cooling Condenser
Raw Water
(Outflow)
CLEARLINE
Treated Seawater
DC Power
Supply
Secondary CLEARLINE Treated
Strainer Line
Primary CLEARLINE Treated
Cooling Line
Seawater
Pump Strainer
Seacock
CLEARLINE
CONTROL UNIT
All ClearCell seawater plumbing connections must be
performed by a qualified marine installation professional.
Failure to turn OFF all seacock valves in the seawater
circuit could result in sinking the vessel.
DO NOT decrease seawater flow below manufacturer’s
specifications for downstream cooling equipment.
Limit the use of 90° elbows as they restrict flow and
cause pressure drop.
Use marine grade hose and double clamp with two
stainless steel clamps, reversing the clamps. Failure to properly secure
seawater connections could result in sinking the vessel.
DO NOT exceed the ClearCell pressure specifications.
The ClearCell is made of 2205 Duplex Stainless Steel for
high corrosion resistance. Do not connect dissimilar metals to the ClearCell.
Use only original parts supplied by ElectroSea. They are
made of special titanium, stainless and other high quality materials. Use of
non-factory or substitute parts will void the Warranty.
CLEARLINE is not for use with engines or generators.
NOTICE
WARNING
NOTICE
NOTICE
NOTICE
WARNING
NOTICE
WARNING
NOTICE
DO NOT USE DESCALING SOLUTIONS, ACIDS OR CLEANING
CHEMICALS AFTER CLEARLINE HAS BEEN INSTALLED. THIS WILL DAMAGE THE
CLEARLINE SYSTEM AND VOID THE WARRANTY.
NOTICE