Electronics Line EL-4800 Manual de usuario

Wireless Outdoor PIR
Two-Way Wireless Outdoor PIR Detector
Model: EL-4800
Installation Instructions

2

3
Table of Contents
Introduction ............................................................................................................................4
Mounting.................................................................................................................................4
Mounting Considerations......................................................................................................4
Installing the Wireless Outdoor PIR Detector in challenging situations ...........................5
Wall Mount Installation .........................................................................................................6
Flat Mounting: ......................................................................................................................6
45° angle Mounting (Left side mounting): .............................................................................6
Changing Back Tamper position: .........................................................................................7
Back Tamper Terminal Wiring ...............................................................................................8
Detection Range Adjustment.................................................................................................8
Walk test .................................................................................................................................9
LED Display ..........................................................................................................................10
Operational Modes ...............................................................................................................10
Transmitter/Receiver Communication link setup ...............................................................10
Optional Swivel Installation (Not Supplied) ........................................................................10
Wall Mounting ....................................................................................................................10
Replacing Lenses.................................................................................................................13
Technical Specification........................................................................................................14
Ordering Information............................................................................................................14
Accessory Kits .....................................................................................................................14

4
Introduction
Electronic Line’s Wireless PIR Outdoor Detector is a unique detector with signal processing
based on two Passive Infrared (PIR) channels. The detector has an adjustable detection range. The
detector is compatible with all Electronic Line’s Wireless and Hybrid systems.
The following instructions describe the installation of the Wireless PIR Outdoor Detector.
Mounting
Mounting Considerations
1. Installation Height: 0.8m - 1.2m
(2'8" – 3'11")
Typical Installation Height: 1m (3'3")
2. To ensure maximum operational reliability, install the detector perpendicular to the ground so
that the upper detection area is parallel to the ground.
3. For optimum detection,
select a location that is likely
to intercept an intruder
moving across the coverage
pattern.
4. Avoid pointing the detector to moving
objects (swaying trees, bushes etc.)
Out of
Detection Range
With moving objects
keep distance of
minimum 5 meters (16')
5m (16')
5. Ensure any objects do not obstruct the field
of view. Pay attention to growing trees or
bushes, plants with big moving leaves etc.

5
Installing the Wireless Outdoor PIR Detector in challenging situations
In the following situations, rapid and significant infrared radiation changes can happen in both
PIR channels together, resulting in false alarms and therefore care should be taken.
1. Situations in which metal and/or glass objects measuring over 70cm (2’4”) in height from the
ground are in the field of view of the detector (cars, metal gates, shutters, metal walls,
windows, etc.)
2. Situations in which a reflective surface on the ground larger than 1m (3’4”) in diameter may
cause reflection into the detector’s lens. Examples of a reflective surface on the ground are a
puddle, wet road or car park, smooth concrete or asphalt surface, swimming pool, etc.
Water Reflection
Notes:
1. Please note that any outdoor PIR detector will require reduction in range to a shorter distance than the car,
metal object or surface reflection (so that these objects won’t be protected) in order to eliminate false alarms.
2. For full 15m (50’) coverage in the above situations, it is highly recommended to install the Wired DT Outdoor
Detector, the only outdoor detector with 2 PIR channels and 2 Microwave channels.
3. Wireless Outdoor PIR detectors include high quality Silicon filters on the PIR sensors for blocking out
white light interferences. These filters are not intended to block infrared thermal radiation.

6
Wall Mount Installation
Note:
The installation knockouts numbering are marked
on the back plate.
1. Open the Wireless PIR Outdoor
Detector front cover (unlock C1, Figure
1).
2. Release internal base (unlock I1, Figure
2).
3. Select mounting installation as follows:
Flat Mounting:
Open knockouts on external base (Figure
3).
•B1 - B4: Wall mounting knockouts
•T1: Back tamper knockout
45° angle Mounting (Left side
mounting):
a. Open knockouts on external base
(Figure 3).
•L1, L2: Left mounting knockouts
•T3: Left tamper knockout
b. Remove tamper spring (Figure 4).
c. Replace tamper bracket (Item 1) with
supplied flat tamper bracket (Item 2).
Item 1
Item 2
d. Insert Tamper lever B onto T6 and T3
and secure screw A (Figure 3).
4. Secure external base to the wall.
5. Insert tamper wires through internal base
(Figure 4).
6. Secure internal base to external base
(lock I1, Figure 2).
7. Close the front cover (Lock C1, Figure 1)
after wiring and setting DIP switches.
8. Walk test the detector.
Figure 1
C1
Figure 2
I1
Figure 3
Tamper
Lever
A
T5
T1
B2
W9
B3
W2
B
L1
T3
B1
L2
W3
B4
R1
R2
(not visible)
T2
T6
(not visible)
T4
W5
W6
Figure 4
Note:
For 45° right side installation use the equivalent units on the external base as follows:
Knockouts Description Lef
t
Righ
t
Mounting Knockouts L1, L2 R1, R2
Tamper spring knockouts T1,T3 T2,T4
Tamper screw anchor T5 T6

7
Changing Back Tamper position:
The back tamper is by default secured on the right
side of the internal base (Rear view). If you wish to
move it to the left side (rear view), do the following
(Figure 5):
1. Remove tamper screw 1 in order to release the
tamper from position 7.
2. Ensure tamper spring (2) rests over tamper wire
base 4.
3. Ensure plastic tamper bracket (3) rests over
both 2 and 4.
4. Secure tamper screw (1) into (3) over position 6.
Figure 5
Left Side
Tamper
Right Side
Tamper
3
6
1
2
4
7
5
Notes:
1. Verify that you hear a "Click" when attaching the tamper spring to the wall.
2. For pole installation, the tamper can be moved to the bottom right-hand side of the internal base.

8
Back Tamper Terminal Wiring
If you wish to use the back tamper (recommended) remove the short from the back tamper terminal
block and connect the back tamper wires to the back tamper terminal block.
Back Tamper in use
BACK TAMPER
Back Tamper not used
Short
H1 H1
Detection Range Adjustment
Slide the moving PIR to the desired
position, see figure 6.
The range of the lower detection area
determines the detection range.
The upper PIR is fixed and its detection
area is parallel to the ground at all times.
The lower detection area changes from
2m to 12m depending on the location of
the moving PIR. Therefore, the detection
range is established according to the
location of the lower PIR since both the
upper and the lower PIR should be
triggered in order to activate an alarm.
Figure 6

9
Detection patterns (side view):
Detection range with 1m (3'3")
installation height:
* Note:
Length may vary according to
environmental thermal conditions.
Note:
No effective detection occurs at distance
less than 2.5 ft from the detector.
Walk test
Two minutes after applying power, walk test the protected area to verify proper operation.
Adjust the moving PIR for required detection range and reliability.
Important!
Both upper and lower detection areas must be blocked simultaneously for detection to occur, see figure 7 below.
Figure 7

10
LED Display
LED State Description
RED Steady Indicates ALARM
Operational Modes
Operational Mode Description
Normal Dead time (between detection alarms) is 2.5 Minutes.
Test (walk test) Dead time (between detection alarms) is 3 sec.
Note:
After power up the detector enters into test mode for a period of 20 minutes (disregarding the DIP Switch Modes
Position).
Transmitter/Receiver Communication link setup
The detector must identify itself to the control panel’s receiver by registering its coded message into
the receiver’s address memory. This is accomplished by performing the following steps:
1. Set the receiver to Registration Mode.
2. Remove the insulation material from the battery and place it in the battery holder on the PCB on
the right direction (pay attention to the "+" and "–" diagram on the PCB)
3. Send a registration message by closing both of the tamper switches (back and cover) for at
least 3 seconds.
4. Verify that the detector has been identified by the receiver.
Caution Notice
Changes or modifications not expressly approved by Electronics Line may void the user’s authority to operate this
equipment.
Simultaneous transmissions from two different units may cause message interference resulting in loss of
information.
The communication quality of this unit may be affected by its surrounding environment. Nearby electrical
equipment may interfere with its normal operation.
The operation of this unit must, therefore, be tested at each installation since its transmission quality may vary as
a result of operational conditions.
Optional Swivel Installation (Not Supplied)
Please follow the instructions below for mounting the detector with the Swivel:
1. Open the Wireless PIR Outdoor Detector front cover (Unlock C1, Figure 1).
2. Release internal base (Unlock I1, Figure 2).
3. Remove back tamper from the internal base (see the “Changing Back Tamper Position"
paragraph on page 7) and connect it to S5 (Figure 8, Detail A) on the Standard Swivel.
4. Select the mounting installation as follows:
Note:
•The swivel mount has not been evaluated by UL
•Ensure that you see the engraved UP mark on the upper front face of the swivel.
Wall Mounting
1. Insert back tamper wires through the Swivel Wires Passage (Figure 8, Detail B).
2. Secure swivel to the wall through holes S1, S3, S6 and S8.
Tabla de contenidos
Otros manuales de Sensor de seguridad de Electronics Line

Electronics Line
Electronics Line EL5845 Manual de usuario

Electronics Line
Electronics Line EL-1484 Manual de usuario

Electronics Line
Electronics Line EL-2650XL Manual de usuario

Electronics Line
Electronics Line EL-4755 Manual de usuario

Electronics Line
Electronics Line EL-4607 Manual de usuario

Electronics Line
Electronics Line EL-2800 Manual de usuario