7
Electron Microscopy Sciences
1560 Industry Road Hatfield, PA 19440
TEL: 215-412-8400 FAX: 215-412-8450 TOLL FREE: 1-800-523-5874
When the machine does not come on at all and there are no lights on machine, this could be an indication
that the timer may be bad. Call and ask for technical support at 813-936-9200. Check the power outlet to
ensure that it is supplying power. Check the 2-Amp line fuse (larger fuse; Part # FUS2). Replace with
spare if required.
TIMER INSTRUCTIONS
- Press and hold clock and then press DAY key, HOUR key, MIN key respectively to adjust clock of
timer to accurate DATE, HOUR, MINUTE. IN 24-HOUR FORMAT, and shall appear on LCD
screen. In 24-Hour-Format LCD screen shall indicate 0:00 (23:59)
Setting the time for timers to turn on:
- Press TIMER key. LCD screen shall show (1 on --: -- )
- Press DAY key 1X till you see all 7 days appear on screen.
- Press HOUR key and type in time example 9 p.m. = 21:00 in military time.
- Press MINUTE key if you want to put in minutes.
Setting the time for timers to turn off:
- Press TIMER key again to set the off time.
- Press DAY key 1X till you see all 7 days appear on screen.
- Press HOUR key and type in time example 6 a.m. = 06:00 in military time.
- Press MINUTE key if you want to put in minutes.
Finish Programming by pressing CLOCK to get out of timer mode. To finalize, press MANUAL
until the indicator line shows AUTO.
To finalize, press MANUAL until the indicator line shows AUTO.
OZONE LEVEL CONTROL
Review the FORMULA below and then:
1. Set OZONE to desired setting
2. Set TIMER to the desired setting
3. Plug the unit into any convenient wall socket
4. Switch the power to ON
5. Monitor odor level and adjust output as required to control odors.