Precaution for safe use.
Be sure to read the product to make it more secure.
The advantages of Hydrogen water generator
Precautions for safe use.
Name of each part.
Product conguration.
How to install before use.
Installation overview.
How operate the system.
How to replace lter.
How to remove remained electrolytic water.
Filter conguration.
Trouble shooting chart
Specications
Certicate of warranty
…
…………………………
………………………………
………………………………
………………………
………………………………
…………………………
………………………………
………
……………………………
……………………………
……………………………
……………………………
2p
4p
5p
6p
7p
8p
12p
13p
14p
15p
16p
17p
18p
Hydrogen Rich Water Purifier
EGT-300 User’s Manual

2
・The characteristic of EGT Hydrogen Water Purifier
Generation of High-Concentrated Hydrogen-Rich Water
Slim and Compact Design
with LED Lightning
•With system control from automatic control
program, hydrogen water with more than
a certain concentration is always provided
by controlling generation of hydrogen, dissolution
timing, concentration control of hydrogen water etc.
(At present, regular concentration of hydrogen
(DH) based on sample device: DH 1,000~1,300 ppb)
(Unit to product Hydrogen-reduced water with the
function of controlling concentration of dissolved
hydrogen: Invention patent).
Easy Filter Replacement
NSF/ANSI 42 Recognized Filter
Material
Adoption DC 12V for Safety

3
Before using a product, please make sure to read "Precautions for Safe Use" carefully and use it appropriately.
• After reading, please keep it in a place where anyone can see at any time.
• Appearance may be subject to change without notice in order to improve the quality of a product.
Precautions for Safe Use.
In the event that serious injury or death may occur in violation of instructions given.
In the event that minor injury or product damage in violation of instructions given.
These graphical figures are symbols for calling a user’s attention to anything and operation which
might cause a hazard.
For the part with these symbols, please read it carefully and follow the instructions to avoid a hazard
that may occur.
When using your appliance, always follow basic precautions, including the following.
Warning
Caution
WARNING
Do not attempt to dissemble or operate the device on your own.
It may cause product damage.
Do not grasp dispensing valve, when moving machine.
Do not place anything on the top of machine.
Connect only to a cold water supply.
Make sure not exceed 3 meter water tubing hose from cold water supply and
do not pull down tubing line.
Do not damage product.
Doing so may causes injury or product damage.
Check with your state and local public works department for plumbing and
sanitation code.
Do not install where the temperature and humidity are high.
For residential and light commercial use only.
Do not use this appliance for other than the intended use.

4
Precautions for Safe Use.
CAUTION
Do not wipe with thinners, benzene, alcohol etc.
Please use it in a safe place with no slope.
Do not connect to a hot water pipe, only cold water taps line.
Connect only to a cold water supply.
Do not move machine when operating.
Make sure the system is plugged into a live 110 - 220 V AC outlet.
Avoid installing the unit where it could be exposed to water or moisture, other heating system.
If the main body falls in the water or water leak from inside of cabinet, immediately disconnect
the plug and then take it out of water.
When the unit is not in use for a long period of time. Please unplug the unit from the outlet
and shut the osupply valve.
If the machine has not been used for a long time, run water through it for 5 minutes or
10 liters over.
Filters should be replaced on schedule and do not change filter set position arbitrarily.
Use only factory authorized filters.
Make sure filter replacement time.

5
1
1
2
3
4
5
2
3
4
5
6
6
7
7
8
8
Middle valve
Feed Water Supply
9
9
Side Panel Fixing Screw
Power Supply
Water Spigot
Water Lever
Side Panel
Drip Tray Grill
Drip Tray
• Name of each part

6
• Product configuration
Inside Structure
1
2
3
4
5
6
7
8
9
10
Hydrogen Generator Module
Device
Hydrogen Generator Module
Drain Cap
LED Light
Drip Tray
Water Spigot
Carbon Filter
UF Membrane Filter
PCB Cover
Pressure Regulator(Reducer)Filter Head
5
8
2
1
6 7
4
910
3

7
Package content
• How to install before use
Please check feed water sources.
Do not use the system on microbiologically
unsafe drinking water.
Please set length of tube between the product and the RO water tank or water bottle within 1m.
More than1meter may result in poor pump performance or reduce water flow.
When connecting to water bottle, fix it so that the water supply tube is immersed in the bottled water bottle.
•
•
Notice: After finishing installation, please run about 2 liters of the water to flush the system.
Please check the components received against your packing slip to make sure
you have all the parts
Diverter ( Optional )
Tubing (1/4 Inch)
Electric adapter and plug
(AC 100~240V,DC 12V 5A)
User’s manual
Adapter valve
⑥Tube outlet deco ( Optional )
Diverter adapters ( Optional )

• Precaution for safe installation
8
• Installation Overview
1. Do not use warm or hot water, as may this damage the machine.
2. Please be sure to turn oadater valve when connecting water supply.
3. Check for any sign of leakage all tubing connections.
4. Check the tubing line is all straight position.
5. Do not let power cord hang over the edge of the table or counter, or touch hot surfaces.
6. Do not operate machine before finishing installation work.
7. Do not install it where the temperature and humidity are high. Keep it in a place it may not be
adversely aected by temperature, sunlight, dust, salt, sulfur content, etc.
Under Sink Type
A typical connection using the included adapter valve is shown in the illustration below.
Connect diverter for water supply to cold water pipe and inhale water up to 1/4inch
●
●
Caution
Please be sure to turn oadapter valve.
Please be sure to connect to a cold water pipe.
Firmly push the inlet water tubing onto the water inlet collar.
Respectively not escape.
Screw nut onto the diverter.
Caution. Install a tubing in a correct position.
Turn on the adapter valve.
Check any sign of leakage all tubing connections.
Cold water pipe
Adapter valve
Inlet water tubing
Middle valve for inlet water
Hot Cold

9
• Installation Overview
Counter Top Type
Connect Water Lines
※
For the first time use, please press and hold dispenser and flush 2 liter water over.
Hot
Adater valve Adater valve
Sink
Cold
Inlet water tubing
Middle valve for
inlet water
①Insert the inlet water tubing to water inlet collar located on the rear of the unit.
②Connect the another end of tubing to the water filter inlet of the adaptor value.
③Turn on the middle valve for inlet water.
④Turn on the water supply valve.
You are now ready to turn the water main back on.
As the system fills, check for leaks and make sure that everything is connected properly.
Run the water to flush the system for about 5 minutes.
You any notice some carbon dust in the water initially.
This is normal and harmless. After flushing the system you should be able to check for clarity
of the water in a clear glass.
•
•
Feed water supply tube
Feed water supply valve
Close Open

10
• Installation Overview
①Measure 3/4” from the ends of tubing ( inlet end) and mark with a pencil.
( Check for roundness, smoothness, cut, nicks, flat spots, and sharp edges.)
②
③
Push the tubing firmly into each fitting on the manifold until the line is flush with the Fitting collar.
(If the tubing is removed, re-cut the end, measure, mark and re-insert).
The tubing must be fully inserted to avoid leaks
(To remove tubing, depress and hold white collet; pull tubing out to remove).
④Pull out slightly on tubing to ensure a good seal. Do no pull too hard or it may damage related parts.
⑤install the other end of the tubing from the inlet side of the manifold of the feed water adapter.
Insert plastic tab to ensure quick- connect fitting cannot come undone.
⑥
①
②
Remove plastic tab from fitting.
Push the collet inward and hold with a finger while pulling the tubing out.
Make sure the collet is pushed evenly on all sides. If only one side is pushed, the tubing
will not be removable.
Making Tubing Connections (Tubing is not performance - tested or certified by NSF)
To Disconnect Tubing :
CORRECT INCORRECT
collet (depress to remove tubing)
tubing
Tubing correctly cut and connected
end of tubing round and smooth.
with no cuts, nicks or at spots
Incorrect partial engagement
correct full 3/4”
Tabla de contenidos