5
The default reference setting is from the rear of the instrument.
Press this button to take the selection from the front edge . A special beep sounds
whenever the reference setting is changed. After a re-startup the reference returns automatically to
the default setting (rear reference).
Press this button again to take the next selection from end piece edge.
Press this button , to set the rear reference again.
In a word, to select the reference level, push button repeatedly until the required reference
level is indicated in the display. Each time after switching on, the rear edge of the measuring tool is
preset as the reference level.
DISPLAY ILLUMINATION
Click illumination button of the display can be switched on or off, User can trigger the
function when he/she is in darkness situation. The value is clear viable on the LCD.
DISTANCE UNIT SETTING FOR INSTRUMENT
Click the button longer change the next type of unit, m, ft. in, ft/in then to continue click the
button for the next unit selection.
MEASURING
SINGLE DISTANCE MEASUREMENT
Press to activate the laser. Press again to trigger the distance
measurement. The measured value is displayed immediately.
Continuous Measurement & Max and Min Measurement The continuous measurement function
(tracking) is used for the transferring of measurements, e.g., from construction plans. In continuous
measurement mode, the measuring tool can be moved close to the target, whereby the measured
value is updated approx. every 0.5 seconds. The corresponding dynamically maximum and
minimum values are displayed in the rst and second line.
As an example, the user can move from a wall to the required distance, while the actual distance
can be read continuously. For continuous measurement, press button until the indicator
for continuous measurement appears in the display. And press it again or press to stop the
function.
The function is terminated after 5 minutes’ continuous measurement.
With this function, customers can measure the max and min distance from a certain point.