2. Introduction 4
2.1 Foreword 4
2.2 Safety Information 5
2.3 Safety notice for methanol cartridges 7
2.4 Normal Operation 7
2.5 Declaration of Conformity 8
2.6 Seals of Approval 8
2.7 Warranty 9
2.8 Disposal 10
3. Configuration 11
3.1 Standard Equipment 11
3.2 Overview 12
3.3 Specifications 13
4. Installation 14
4.1 Installation Space Requirements 14
4.2 Mounting of the Fuel Cell 16
4.3 Connecting the Off-Heat Duct 17
4.4 Connecting the Exhaust Hose 18
4.5 Installing the Fuel Cartridge Holder 20
4.6 Electrical Connection to the Battery 21
4.7 Combination with other energy sources 24
4.8 Connecting the Remote Control 25
5. Operation 27
5.1 Integrated user interface 27
5.2 Remote Control 28
5.3 Select Language 30
5.4 Remote Control with Computer 30
5.5 Connecting the Fuel Cartridge 31
5.6 Automatic Operation 33
5.7 Switching On manually 34
5.8 Switching Off manually 34
5.9 Battery protection 35
5.10 Automatic Antifreeze Feature 36
5.11 Storage 37

1. Table of Contents
3
6. Maintenance 39
6.1 Service 39
6.2 Cleaning 39
6.3 Change the filter (EFOY Pro 2200 XT) 40
6.4 Disposal Filter XT1 42
6.5 FAQs und Service 42
7. Troubleshooting 44
7.1 Safety 44
7.2 Problems and Solutions 45
7.3 Problems without Error Messages 47
7.4 Replacing Service Fluid 48
8. Data Interface and Accessories 49
8.1 Data Interface Functionality 49
8.2 Computer Interface Adapter 49
8.3 GSM Modem GSM-2-SMS 50
8.4 Fuel Level Sensor FS1 50
8.5 Cluster Controller CC1 51
8.6 EFOY ProCube 52
8.7 DuoCartSwitch 53
9. Appendix 54
9.1 Accessories and Spare Parts 54
9.2 Output characteristic 54

2. Introduction
4
2. Introduction
2.1 Foreword
Thank you for purchasing an EFOY Pro product. We hope
that you will enjoy your new unit.
Please read these instructions first before using and
follow the installation instructions.
Please contact our sales partner where you have bought
the product in case you have questions about installation
or operation.
Manufacturer’s address:
SFC Energy AG
Eugen-Sänger-Ring 7
D-85649 Brunnthal-Nord
Phone: +49 89 673 5920
Fax: +49 89 673 592 369
Email: Sales@sfc.com
web: www.efoy-pro.com

2. Introduction
5
2.2 Safety Information
Read the instructions before operating and keep them
nearby. Be sure to follow all directions in the manual.
Do not open unit or fuel cartridges. Do not use force to
open cartridges and do not refill them. Any
modifications to the unit may affect safe operation, will
lead to a loss of license and will void the warranty. Use
only original EFOY equipment.
Do not store unit and fuel cartridges at temperatures
above 45° C. Do not operate at temperatures above
45° C. Keep away from heat and direct sunlight.
Store the unit where there is no danger of freezing, or
use the automatic antifreeze feature. (see Chapter 5.10)
Do not smoke when handling the unit or the fuel
cartridges.
Keep away from heat and open flame.
There is a danger of fire if methanol leaks out (i.e.
following an accident, or if the unit or the fuel cartridge
has been damaged). Keep away from open fire and
make sure area is well ventilated. Small amounts of
methanol which may leak out will evaporate without
leaving any residue.
Keep unit and fuel cartridges (including empty or
partially filled cartridges) out of children’s reach.
Operate the unit only in accordance with instructions
and keep operating area well ventilated. Do not block
exhaust. Avoid inhaling exhaust fumes directly or for
prolonged periods of time.

2. Introduction
6
There is no risk of coming into contact with methanol
provided that you handle the unit and fuel cartridges in
accordance with instructions.
We are required by law to print the following notice.
Methanol is toxic if inhaled, ingested or if it comes into
contact with skin. Irreparable damage may occur if
inhaled, ingested or if it comes into contact with skin. In
the event of an accident or if nausea occurs, consult a
physician immediately. Be sure to bring the fuel
cartridge label or these instructions to the consultation.
(A caution concerning methanol can be found in the
appendix.)
System exhaust may contain harmful components.
Avoid inhaling exhaust directly or for prolonged periods
of time. Use the exhaust hose to conduct exhaust gases
to the exterior.
Improper use or improper connection to other electrical
devices may result in damage.
WARNING
In addition to these safety instructions, please observe
the passages in bold type. Otherwise, you may
endanger yourself and others.

2. Introduction
7
2.3 Safety notice for methanol cartridges
WARNING
You are given the methanol in the form of safe, tested
fuel cartridges that protect you from coming into
direct contact with the contents if used correctly. We
are required by law to print the following notice.
Methanol is easily flammable. Methanol is toxic if
inhaled, ingested or if it comes into contact with skin.
In the event of an accident or if nausea occurs, consult
a physician immediately. Be sure to bring the fuel
cartridge label or the methanol material safety data
sheet to the consultation.
Storage and transport of methanol may be subject to
statutory regulations.
More information is provided in the methanol safety
data sheet on our website ww.efoy-pro.com or by SFC
directly.
2.4 Normal Operation
The EFOY Pro fuel cells are automatic charging devices
for 12V and 24V lead batteries.
The unit may be used only to charge lead batteries that
conform to the specifications in Chapter 0.
The unit can be used according the specification in
Chapter 0 for stationary and mobile operation in vehicles.
Operate only with original-equipment EFOY fuel
cartridges.
The unit is not intended for emergency medical power
generation, or for powering life-sustaining or agricultural
devices.
The parallel operation of units to increase the charging
current is possible.

2. Introduction
8
The serial operation of units to increase the voltage
output is not permitted.
Do not operate unit if housing is damaged.
2.5 Declaration of Conformity
SFC Energy AG, Eugen-Saenger-Ring 7, 85649 Brunnthal-
Nord declares that the EFOY Pro 600, EFOY Pro 1600,
EFOY Pro 2200 and the EFOY Pro 2200 XTconform to the
European Community’s 2004/108/EG guidelines for
electro-magnetic compatibility. The following norms
apply: DIN EN 61000-6-1, DIN EN 61000-6-3
2.6 Seals of Approval
These units have been tested in accordance with ECE
Regulation No. 10 for electro-magnetic compatibility.
Operation in motor vehicles is permitted.
Approval number: E24 10R-020234
These units have undergone voluntary testing by TÜV
SÜD for conformity with the basic requirements of IEC
62282-5 and have been awarded the seal of approval for
product safety.
E 24

2. Introduction
9
2.7 Warranty
The warranty period begins when the new unit is purchased.
Your proof of purchase can be used as a record of this date.
Please keep these documents carefully. Our warranty
services are based on the SFC warranty conditions which are
valid at the time of purchase.
Service
For technical queries on EFOY Pro fuel cells, our EFOY
customer service can be reached during office hours at the
following numbers:
Freecall (Germany): 00800 / 73 27 62 78*
From any other country, please dial:
+49 89 / 673 5920
SFC Energy AG
Eugen-Sänger-Ring 7
85649 Brunnthal-Nord
Germany
Fax.: +49 89 / 673 592 369
Sales@sfc.com
www.efoy-pro.com
*The freecall number is available from the following countries: Germany, Belgium,
Denmark, France, Great Britain, Italy, the Netherlands, Norway, Austria, Sweden,
Switzerland and Spain.

2. Introduction
10
2.8 Disposal
Packaging
Packaging protects your unit during shipping. All
materials used are environmentally compatible and
recyclable.
We recommend saving the packaging for eventual
winter storage.
Should you nevertheless wish to dispose of the
packaging, please do so properly.
Your dealer or your local recycling center can provide
information about proper disposal.
WARNING
Danger of Suffocation!
Keep packaging away from children. Plastic wrapping
and cartons may cause suffocation.
Fuel Cartridges
Sort empty fuel cartridges with plastics. Dispose of
partly filled fuel cartridges in the same manner as
solvents or paint.
Old Units
Old units are still valuable! Proper disposal can yield
valuable raw materials while protecting the
environment. Your supplier can advise you about
returning old units.

3. Configuration
11
3. Configuration
3.1 Standard Equipment
The following is included in the standard delivery
package:
EFOY Pro fuel cell
Remote control with data line
Fuel cartridge holder with belt
Mounting plate for EFOY Pro
Off-heat duct
Exhaust hose
Charge line
Service Fluid
User manual
A basic-set is also available on demand:
EFOY Pro fuel cell
Service Fluid
User manual
Unit
Remote control with data line
RC1
Fuel-cartridge holder with
belt FH1
Mounting plate
Exhaust hose EH1
Off-heat duct OD1
Service Fluid
Charge line CL4:
Connecting line to fuel-cell 1m
Battery fuse power 15 A Battery fuse sense 2.0 A
Length 0,5m Length 0,5m
Otros manuales para EFOY Pro 600
1
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Otros manuales de Fuente de alimentación de EFOY

EFOY
EFOY COMFORT80 Manual de usuario

EFOY
EFOY ProFuelBox Manual de usuario

EFOY
EFOY Updater Manual de usuario

EFOY
EFOY Pro 800Pro 800 DuoPro 2400Pro 2400 Duo Manual de usuario

EFOY
EFOY GO! Manual de usuario

EFOY
EFOY Pro 800 Manual de uso y cuidado

EFOY
EFOY ProCube 2060A-3 Manual de usuario

EFOY
EFOY COMFORT 80 Manual de usuario

EFOY
EFOY Comfort Series Manual de usuario

EFOY
EFOY ProEnergyCase 2020P-3 Manual de usuario