Effecta Komplett III Manual

Rev. EA. 015-08-24
INSTALLING
MAINTENANCE
SERVICE
ASSEMBLY
EFFECTA KOMPLETT III
20-25-35 kW

2
We at Effecta would like to thank you for putting your trust in us when choosing your new
boiler. The ”Effecta Komplett III” has been developed to give you maximum performance,
comfort and quality. In order to get the best results from your boiler, we suggest that you
follow the recommendations in this installation guide.
Checking your delivery
Check that the boiler has not been damaged during transportation. If the boiler has been
damaged, you must report this to the transportation company immediately.
Your safety
If you discover any faults or defects in our products, it is important that you report them as
quickly as possible to your installation engineer, so that the fault can be rectified. Make sure
that there are no flammable materials close to the boiler, to help prevent risk of fire. You must
use your own judgement when operating the pellet boiler. Remember that the hatches and
some surfaces can get hot. You must take care to avoid being burnt.
The user
It is the user´s responsibility to operate the boiler according to our instructions. If you do
not operate and maintain your boiler correctly, the environmental impact of the boiler will be
greater, its efficency will be reduced and the service life of some components will be shorter.
If there is anything that you are not sure about, please contact your installation engineer or
Effecta for advice.
Warranty
The warranty takes effect from the date on which the boiler is installed. The supplied
installation form must be completed and returned to Effecta. You can find the other guarantee
terms on (page 3).
▀ Scope of delivery
Please check all components delivered.
The standard delivery as follows:
- Effecta Komplett III boiler
- Cleaning handle with brush
- Rake with scraper
- Flue attachment
- Draft stabiliser
- Turbulators, 8pcs.(mounted)
- Drain cock
- Shunt valve + motorized shunt control, not in ”Light” version
- Electrical heater 3-9 kW (mounted), not in ”Light” version
- Thermostatic mixer valve, not in ”Light” version
- Room thermostat, optional in ”Light” version
- Outdoor sensor, optional in ”Light” version
▀ Introduction

3
Effecta products are guaranteed to be free of defects in materials. The main body has a 5 year
warranty against leakage of water and all other parts have a 2 year warranty.
The warranty also covers original spare parts. Any faulty products will be replaced or repaired at
the discretion of the retailer or Effecta. If a faulty product is detected, Effecta is entitled to
replace it with a new or reconditioned product of the same or a similar type.
If you have a complaint, you must contact your retailer before starting any servicing work.You
must submit your complaint without delay. You must always state the type of product, the date of
purchase and the serial number.
Otherwise the heating and plumbing industry’s current regulations apply in case of complaints.
Guarantee terms:
The guarantee is valid on condition that:
- The boiler and the heating system have been installed in accordance with the installation
instructions and in a professional manner.
- The location where the product is installed is suitable for purpose.
The guarantee does not cover:
- The overall function of the heating system, costs incurred as a result of the heating
system being out of operation, or the cost of the temporary replacement of products.
- Damage or injury caused by negligence during the installation or by operating the boiler in
a way which conflicts with the installation and user instructions.
- Damage caused by abnormal wear, incorrect operation and maintenance.
- Damage caused by the use of non-original spare parts.
- Damage caused by the boiler being positioned in an unsuitable location.
- Damage caused by vermin.
The terms may be different from country to country. Check with your installer.
▀ System data:
▀ Warranty
Installer:
Date:
Electrical installer:

4
▀ Contents
2 Introduction 43 Cleaning
2 Scope of delivery 44 Cleaning and service
3 Warranty 45 Service
3 Warranty terms 46 Service
3 System data 47 Adjusting door to ash compartment
4 Contents 48 Troubleshooting
5 In general 49 Documentation of settings
5 Symbols in this document 49 Technical data
6 Your safety 50 Technical specification K3 external feeding
7 Safety components 51 Technical specification K3 internal storage
8 Components 52 Technical specification K3 suction system
9 Fuel 53 Connection suggestions internal hotwater and radiators
10 Boiler room 54 Connection suggestions radiators and heaters
11 Placement of components K3 external feeder 55 Connection suggestions accumulator tank with solar heating
12 Placement of components K3 internal storage 56 Connection suggestions several heating cicuits
13 Placement of components K3 vacuum system 57 Component placement K3
14 Placement of components K3 vacuum system 58 Component placement K3
15 Placement of components K3 internal storage 59 CE
15 Placement of components K3 electrical system
16 Placement of components K3 burner
17 Cleaning system burner
18 Cleaning system boiler
19 Disassembly for move
20 Function suction system
21 Suction system and storage
22 Installation of suction nozzles
22 Installation of hoses
23 Electrical connection
24 Outlets of the circuit board
25 Outlets of the circuit board
26 Electrical Schematic
27 Electrical Schematic
28 The menu system
29 The menu system
30 The menu system
31 The menu system
32 The menu system
32 Alarms
32 Update software
33 Tuning the boiler
34 Tuning the boiler
35 Hot water
35 Valve combination
36 Shunt control
37 Tuning the boiler
38 Examples of curves
39 Mounting draft regulator
40 Overheated fallshaft
40 Replacing the combustion fan
41 Replacing the igniter
42 The chimney
42 Flue attachment

5
The boiler
Effecta Komplett III is a boiler which is to be fueled with wood pellets. No other kind of fuel is
allowed, not logs or oil.
Disassembly and disposal
It will be many years before your Effecta boiler is worn out, but it is important that you follow
the regulations in force at the time concerning disassembly and disposal of your boiler.
The fuel
The boiler should burn 6 mm ø pellets which come either in sacks or are supplied by bulk truck.
If you have built a bulk storage, you should follow the current recommendations to ensure that
the quality of the pellets does not deteriorate. Never use pellets which do not meet European
pellet standards DIN+, as this may result in problems in operating the burner.
▀ In general
▀ Symbols in this document
Information
This symbol is shown with to indicate important information the installer should know and
understand. Neglecting this information can affect the performance of the product.
Dangerous electricity
This symbol means that extra caution should be taken otherwise serious personal injury
might occur. When maintaining the product where this symbol is present the power must
be disconnected. All electrical wiring must be done by a Professional and comply with
current building regulations.
The product manual is a document that gets updated. You always find the latest version
on our webpage www.effecta.se
Hot surfaces
This symbol is shown when there is a risk of burns to people. Always wait for the boiler to
cool down before you do any service.

6
▀ Your safety
Before using the product, the owner and/or other user must read and understand the content
in this manual. The directions must be followed. This is to make sure that the product is
functioning correctly so accidents and injuries are avoided. Incorrect use or burner adjustment
can result in damage to property and personal injury or poorer performance of the product.
The boiler room where the product is installed, the chimney and other components must be
approved according to current legislation.
The commisioning of the product must be made by a professional, according to Effectas
directions and current legislations. Controls and tuning of the product should be made by a
professional. A chimney sweeper should also be contacted when commisioning the product.
The electrical connections must be done by a qualified electrician, according to Effectas
instructions in this manual.
The casing outside of the burner must always be fitted on the boiler when the boiler is
connected to the electrical power. Before cleaning and maintenance of the product, make sure
it is disconnected from the main power.
It is strictly forbidden to open any doors when the burner is igniting. If any door or hatch is
opened when the burner is running, great caution must be taken. Any kind of interference or
use of anything other than original spare parts can result in damage to the product or person. It
also removes Effecta from any liability.
It is strictly forbidden to make any changes or alterations to the boiler without prior approval
from Effecta. If any changes are made, the safety functions, or any other function, might not
work as it is supposed to, and all warranties and liabilites from Effecta are cancelled.
This manual should be kept during the whole life span of the product. Any updates will be
reported on the Effecta web page: www.effecta.se.
Remember to always disconnect the power before working with the boiler.
Wait until the boiler has cooled down before starting work.

7
Drop tube
Between the storage and the feeder there is a meltable plastic tube which is
destroyed when it is overheated.
The overheat protection on the fall shaft
This stops the feeding and the fire damper if the fan temperatures gets
too high. Reset is made manually.The cover must always be in place when
connected to main power. It only cuts the power to the auger and fire damper.
Safety lock
If the boiler is equiped with a suction system there is a fire damper mounted.
This is closed during filling, overheating or loss of power.
Flame sensor
The flame sensor monitors the flame in the burner. If a valid value is lost for
more than 120sec the feeder stops. The burner is cooled down with maximum
rpm of the fan for (X) minutes before stopping. The pellets suction is not
allowed to start if the flame sensor detects light
Overheat protection on the boiler
There is overheat protection on the boiler which cuts the power to both the
boiler and the burner if the temperature in the boiler exceeds 95°C.
Compressed air cleaning
On the cleaning to the burner there are two safety systems. The controller
limits the the time the compressor is allowed to run, there is also a pressure
switch which closes the compressor when preinstalled pressure is reached.
Flue gas fan
A flue gas fan is mounted on the flue tube. The fan helps to maintain a stable
underpressure in the boiler and prevents back heat but also improves the com-
bustion. More on the fans adjustements are on pg. 33.
Door switch
The door switch stops the auger/feeder and no more pellets are fed into the
burner when the door to the combustion chamber is open.
Automatic fuses
Automatic fuses are installed in the electrical system, which are triggered if
there are any eletrical faults in the boiler. If triggered, an authorized electrician
should be contacted to determine the cause.
▀ Safety components

8
The shunt valve
The shunt valve is connected to the boiler or accumulator tank.The shunt valve
controls the heat supply from the boiler to the heating circuits of the house.
Heat regulation
The boiler is equiped with its own heat regulator. In the ”Shunt control” menu you
can choose how to control the heat in the house. More on how to regulate the
heat is found on pg. 36.
The thermostatic mixer valve
The mixing valve is used to ensure that the temperature of the hot water in your
shower and elsewhere in the house is comfortable. Set the system to the tem-
perature you want by turning the thermostat between +/-. If you have a Komplett
Light the mixer valve is mounted on the accumulator tank.
Feeder
The feeder is either internal or external on the boiler. The feeder controls the
amount of pellets fed to the burner.
The burner
The burner is mounted on either the right or left side. The fuel from the feeder is
ignited and combusted, which heats up the water in the boiler.
Turbulators
Within the tubes in the heat exchanger hang the turbulators. The turbulators function
is to transfer heat from the flue gas to boiler water. They must always be placed in
the boiler. If the flue gas temperature in the chimney is too low, the turbulators can
be cut off to increase the temperature.
Draft stabiliser
The draft stabiliser gives the boiler stabile draft conditions, this improves
combustion and efficiency.
Hot water coil
Within the boiler is a hot water coil that heats up the water for the house. The
water you can drain from the boiler depends on the boiler temperature, the mount
of flow you through and which effect the boiler is set to. We recommend a flow
of 12-42l/min in the taps. In the Light model there is no coil, here you heat your
water in a external water heater.
The sealings
The seals on the hatches must be checked every year. If the hatches do not seal
properly, the efficiency and the combustion process of the boiler will deteriorate.
Dust and ash can also leak out during cleaning.
▀ Components

9
Wood pellets are made of sawdust, a byproduct from handling wood. Wood contains lignin that
makes the pellet hard without any glue or other binder being used.
There are several different kinds of pellet on the market. The quality and energy can vary
between them. The diameter is 6-8mm, the normal length is between 5 and 30mm.
High quality pellets have a density of 600-750 kg/m3. The moisture content is 5-9% in weight.
Oil has an energy content of 9,9kWhr/kg and wood logs about 4,0kWhr/kg. Wood pellets have
a energy content of 4,7-5,0kWhr/kg. To maintain good combustion the pellets should be stored
in a dry place and be protected from dirt. Pellets are delivered in sacks with 10-15kg content or
in bulk by truck.
The Effecta Komplett III can handle most of the different types of wood pellets that are between
6-8mm, but in UK only 6mm should be used. The quality should meet DIN+ standards. Good
pellets with a small amount of dust and that are uniform helps achieve good combustion, less
maintenance of the product and also less environmentally harmful emissions.
The worse the quality of fuel is, the more cleaning and maintenance of the product will be
required.
▀ The fuel
The amount of pellets fed into the burner should be controlled every time the pellet
brand or quality is changed. If the deviation is more than 0,5kg/hour compared to the
numbers in the ”Warranty and Installation” paper, the burner should be tuned.

10
▀ Boiler room
It is time to install the Effecta Komplett III pellet boiler. Please follow the examples we provide
for a safe installation. After installation, be sure to instruct the customer on how the heating
system and the boiler works, in order to avoid unnecessary complications in the future.
Set up
The boiler is positioned so that the
surface temperature of flammable
building material does not exceed
80°C. The boiler should be positioned
at least 10 cm (1) from the wall. If the
distance between the flue tube and
flammable wall is less than 30 cm
an ignition protective covering
must be used (4). In order to
clean the boiler, a minimum
clear space of 1 metre (2)
is required in front of the
boiler. A passage with a
minimum width of 0.5m (3)
is required along one of
the long sides of the boiler.
Check the regulations of your
country in order to place the
pellet hopper an approved
distance from the boiler.
Boiler room
The boiler must be installed in a boiler room or boiler house. The ceilings and walls must
be fitted with ignition protective covering and the floor must be made of non-combustible
material. Minimum ceiling height in the boiler room is 2 metres. The boiler room or boiler house
must be equipped with a fresh air intake with the minimum dimensions 150 x 150 mm(5.) or
with a sufficiently large free sectional area to avoid low pressure in the boiler room. It must be
impossible to close the air intake.
Chimney
The chimney should have enough area to manage the effect from the boiler. At standstill the draft
should be between 5-10pa. It is important that the chimney is tested and approved by a HETAS
approved installer before a new boiler is installed. If the chimney is tall and has a lot of mass to
heat up there is a risk of condensation. Measure the temperature 1m down from the top when the
burner is running, the temperature should be 70°C.
Read more about the chimney on pg 42.