CAUTION. Never leave RADIASOL
exposed to the sun without water. If the
exchanger needs to be le empty, make
sure it is protected by a re-resistant and
non-transparent cover.
CAUTION. It is compulsory to install a
thermostac mixer valve downstream of
the connector (hot water outlet) to avoid
users to get burned and to opmise the
exchanger’s performance.
CAUTION. EDN recommends installing
RADIASOL in limited access areas. The
surfaces’ high temperatures and the
safety valve’s sudden opening may cause
serious injuries. Please keep in mind that,
in case of ground installaon, the area
should fenced o.
RADIASOL must be installed on suitable
bolsters designed by a structural engineer,
and equipped to support the exchanger’s
gross weight (see Technical Informaon).
Snow, wind and seismic acon must be
calculated according to the place chosen
for the installaon and in compliance with
the naonal laws.
The frame anchoring inserts (not
included) must be suitable for the surface
type and the bolsters’ material.
CAUTION. Central heang installaon
and operaon must comply with appli-
cable local laws and regulaons.
CAUTION: Before installaon, please
store the packaged equipment in a
dry place, and on a steady ground or
shelving.
PPE
Accessories Features – use Normave
reference
Light protecve
gloves
For mechanical operaons: resistant to
abrasion, cuts, tearing and puncture EN 388
Lace-up safety
footwear With an-slip sole, an-stac, an-puncture EN 345
Industrial
safety helmet
Insulang, chin-strap harness structure (when
working near overhangs at a height of 1100 mm
- 2300 mm)
EN 397
Protecve
clothing Made with an-stac fabrics EN 1149
EN 430
“Linee Vita®“
equipment
Stainless steel protecve panels against falls
- especially during the rst installaon and/
or for maintenance operaons.
UNI EN 795
Lightning protecon EN 62305
Roof works dangers:
• Make sure that all necessary safety precauons are taken
during roof works, especially to reduce the risk of falls.
• Protecve safety clothing should be worn at all mes.
• Once works are completed, the assembly kit xing,
the framework and the exchanger should be carefully
checked.
The table data can be modied, updated and/ or
superseded by applicable laws which must be strictly
complied with:
ANY OTHER AND/OR NEW LAWS APPLICABLE AT
THE TIME OF OPERATION SHALL PREVAIL OVER THIS
MANUAL.
3.2 Delivery and handling
RADIASOL is delivered in a cardboard box containing
the follow equipment:
- installaon, use and maintenance manual
- safety valve
- check valve
- 3/4 brass ngs kit
- air outlet valve (only for horizontal installaon)
Ground and roof frames (oponal) are delivered in a
separated package, together with assembly screws.
Exposure me to receive paral thickness burns
Temperature
70°C
60°C
50°C
Adults
1 sec
5 sec
5 min
Children 0-5 years
---
1 sec
2,5 mins
EDN recommends that the professionals dealing with
the exchanger’s installaon and roune and emergency
maintenance should use the following Personal
Protecve Equipment (PPE) and related accessories.
3. SAFETY REGULATIONS