Minimum Clearance to Combustibles
Location of the Pellet Fire
Installation of the Ecoteck Amal Freestanding Wood Pellet Burning Heater should be
undertaken by an experienced installer. Please read the Amal Owners/Technical Manual
thoroughly before commencing installation as failure to follow the instruction could cause
damage to the pellet re or property.
Positioning the re:
Generally Amal should be installed in a centrally located position within the home. When
deciding where to position the appliance in your room you need to consider the following:
Location of a power source
• Amal has a convection fan which blows air through tubes in the direction that the re
faces, for optimum performance this location should be in a large room centrally located.
• Amal must be installed on a non-combustible surface. This surface must protrude
150mm from the front of the closed pellet re door.
• Amal has been Safety Tested to AS/NZS 2918 using the Davins manufactured ue.
Test Report ARS 05/1185. Installation is not exclusive to these nominated kits, though
alternative ue should only be considered following consultation with your local council.
• Please consult pages 2 & 3 for the required clearances to combustible material also
ensure the position of structural elements near the proposed ue.
• Because of the positive pressure in the ue, sealing of all 75mm stainless joints is
mandatory – use high temperature Maniseal. Both inner and outer ue joints must be
riveted.
• Seismic Restraint: Please view page 6 for requirements.
• Warranty: To validate warranty following installation a copy of the completed Warranty/
Producers Statement must be forwarded to: Nature’s Flame- Fax (03) 348 1743.
Side of Unit (B) 200
Rear wall to Lined Flue (D, L, J) 50
Rear wall to Unlined Flu (D, L, J) 75
Rear of Unit (M) 200
Rear corners (Corner Installation) (G) 100
Floor protection (from glass) (C) 150