Ecosoft ROBUST 1000 Manual del propietario

СИСТЕМ ОБРАТНОГО ОСМОСА
ECOSOFT ROBUST 1000, ROBUST 1500,
ROBUST PRO, ROBUST 3000
FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500,
ROBUST PRO, ROBUST 3000
ИНСТРУКЦИЯ ПО ПОДКЛЮЧЕНИЮ И ЭКСПЛУАТАЦИИ
INSTALLATION AND OPERATION GUIDELINES

2
Carefully read this manual before installing the system.
Do not open plasc bag with reverse osmosis system components before you make sure it contains
all parts. Missing part claims will not be accepted if the package is broken.
The manufacturer reserves the right to amend design or components of the product, if such
amendment does not result in deterioraon of its quality and performance.

2
3
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2017
INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500, ROBUST PRO, ROBUST 3000
CONTENTS
1Application 4
2Specifications and components 7
2.1 Technical specifications 7
2.2 Feed water requirements 8
2.3 Reverse osmosis systems components 9
3 Installation diagrams 13
3.1 ECOSOFT RObust base model 13
3.2 ECOSOFT RObust with pressure tank 13
3.3 ECOSOFT RObust with pressure tank and ultraviolet unit 14
4 Installation steps 14
4.1 Installation conditions check 14
4.2 Installation 14
5 Post-installation 16
6 Operation 17
6.1 Average lifespan of systems components 18
6.2 Filters replacement 18
6.3 Membrane replacement 19
7 Sanitization 19
8 Troubleshooting 20
9Maintenance record 22
10 Health and environment safety information 24
11 Transportation and storage 24
12 Warranty 24
13 Authorized services in your area 26

4
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2017
INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500, ROBUST PRO, ROBUST 3000
1. APPLICATION
Robust reverse osmosis systems are designed for water puricaon using reverse osmosis
membranes — special semipermeable membranes that allow purifying tap water from all harmful
impuries, including nitrates and viruses (see Figure 1 below).
RObust is a mulstage direct ow ltraon system, which operates according to the following
scheme:
• Feed cold water rst undergoes pre-ltraon (1st pre-lter in the Robust 3000 system or 1st and
2nd pre-lters in other systems) where it is stripped of suspended parcles (rust, sand, hemp
strands etc.).
• The pressure booster pump feeds water to the reverse osmosis membranes mounted in parallel
or in series. If the supply of feed water is cut o or the input pressure is lowered below 0.15-0.2
bar, a low-pressure switch is triggered, closes the inlet valve and turns o the pump. Even when
the puried water faucet is opened, the system will not start unl the supply of feed water is
restored with sucient pressure.
• Permeate (puried water) goes to puried water outlet or pressure tank outlet (if installed),
passing through the carbon post-lter, and the concentrate — through the ow restrictor is
discharged into the drain.
• RObustPro system is equipped special RObustPro replacement lter allows to get water with
a small content of magnesium and calcium, which enhance the extracon of coee avor and
aroma components.
High pressure switch installed before the post-lter reads pressure in permeate line and starts the
reverse osmosis system when the pressure drops (due to taking of some water from the pressure
tank or opening puried water faucet). When the system switches on, entry solenoid valve is
opened and booster pump is powered up, which allows feed water into the system. When puried
water faucet is closed, pressure starts to build up, closes high pressure switch turns o the system.
On the Robust system front panel there are two pressure gauges. One shows the water pressure
aer the pre-lters, and the second shows the pressure aer the pump in the membrane unit.
The panel also provides informaon on requirements, recommendaons for resolving possible
problems if requirement are not met.
Figure 1. Reverse osmosis process illustraon
Tap water under
pressure
Concentrate
for disposal
Membrane
Water
molecules
Molecules of smaller
size, pure water
Larger molecules

4
5
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2017
INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500, ROBUST PRO, ROBUST 3000
Figure 2. RObust 1000
Figure 3. RObust 1500
Water
inlet
1/4''
Inlet
Sediment
lter
Carbon
lter
Low
pressure
switch
Afterlter
pressure
gauge
solenoid
valve
Booster
pump
RO element
Operating
pressure
gauge
High
pressure
switch
Carbon
lter
Drain
outlet
1/4''
Tank
connection
1/4''
Permeate
outlet
1/4''
Flow
restrictor
Water Inlet
inlet
3/8''
Sediment
lter
Carbon
lter
Carbon
lter
Afterlter
pressure gauge
Low pressure
switch
solenoid
valve
Operating
pressure
gauge
Drain
outlet
1/4''
Tank
connection
3/8''
Permeate
outlet
3/8''
High pressure
switch
Check
valve
RO element
Flow
restrictor
Booster
pump
Flush
valve

6
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2017
INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500, ROBUST PRO, ROBUST 3000
Water
inlet
3/8''
Carbon
lter
Inlet solenoid
valve
Afterlter
pressure
gauge
Low pressure
switch
Booster
pump
RO element
Operating
pressure
gauge
Flow
restrictors
Drain
outlet
1/4''
High
pressure
switch
Carbon
lter
Tank
connection
3/8''
Permeate
outlet
3/8''
Flush
valve
Figure 5. RObust 3000
Water Inlet
inlet
3/8''
Sediment
lter
Carbon
lter
Afterlter
pressure
gauge
Low pressure
switch
solenoid
valve
Check
valve
Operating
pressure
gauge
Flow
restrictor
Drain
outlet
1/4''
Tank
connection
3/8''
Permeate
outlet
3/8''
High pressure
switch
Carbon lter
RObustPro lter
Check
valve
RO element
Flow
restrictor
Booster
pump
Flush
valve
Figure 4. RObust PRO

6
7
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2017
INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500, ROBUST PRO, ROBUST 3000
1 At feed water TDS of 1000 ppm and temperature of feed water of 25 °С, ±10%.
2 If pressure of water in your system does not meet requirement, install a pressure booster pump to raise it. If
water pressure exceeds the upper limit, install a pressure regulator before the RObust.
3 Using the RObust with feed water temperature between +20 and +30 °С produces a lower rejecon rate and
higher ow rate, which yields higher TDS of puried water. Using the system with feed water above +30 °С is
advised against.
2. SPECIFICATIONS AND COMPONENTS
2.1 TECHNICAL SPECIFICATIONS
Parameter
Value
RObust 1000 RObust 1500 RObust Pro RObust 3000
Puried water ow rate1, L/h 55–60 70–75 70–75 145–150
Feed water ow rate, L/h 110–125 140–150 140–150 290–310
Concentrate ow rate, L/h 55–65 70–75 70–75 145–160
Inlet water pressure, bar 2,0–5,02
Operang pressure, bar 5,0–7,0
Feed water temperature, °С +4…+303
Ambient air temperature, °С +5…+403
Connecon to water mains ½"
Overall dimensions,
H × W × D, mm 420x425x220 420х410х305 420х410х305 445x480x380
Weight, kg, max. 6 9 10 25
Electrical rang 230 V, 50 Hz
Power consumpon, W, max. 80 80 80 250
Ingress protecon rang IP 54

8
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2017
INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500, ROBUST PRO, ROBUST 3000
2.2 FEED WATER REQUIREMENTS
Parameter
Value1
RObust Pro ROBust 1000, ROBust 1500,
ROBust 3000
pH 6,5…8,5
TDS, ppm 250-500 < 1500
Total hardness 100–400 ppm CaCO3< 500 ppm CaCO3
Alkalinity 100–200 ppm CaCO3< 325 ppm CaCO3
Active chlorine, ppm < 0,5
Total iron, ppm < 0,3
Total manganese, ppm < 0,05
Chemical oxygen demand,
ppm O2
< 5
Total microbial count (TMC),
(CFU per 1 mL) < 100
E. coli (CFU per 100 mL) None
1 If feed water quality does not meet specied requirements, membrane and lter service life may decrease. If
aiming to purify raw water (well water/ground water etc.), it is recommended to carry out detailed water anal-
ysis. If any constuents exceed the above limitaons, it is advisable to install a special lter upstream of your
reverse osmosis system. Consult professional water treatment specialist for proper selecon of an appropriate
lter for your water.

8
9
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2017
INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500, ROBUST PRO, ROBUST 3000
1) Assembled lter 2) Pre–lters and
post–lter
3) Reverse osmosis
membranes
2.3 REVERSE OSMOSIS SYSTEMS COMPONENTS
ROBUST 1000
7) Feed valve
PP5 GAC CTO
8) Set of tubes
and ngs
9) Service wrenches
4) Feed adapter 5) Drain saddle 6) Puried water faucet

10
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2017
INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500, ROBUST PRO, ROBUST 3000
1) Assembled lter 2) Pre–lters and
post–lter
3) Reverse osmosis
membrane
ROBUST 1500
PP5 GAC CTO
8) Set of tubes
and ngs
9) Service wrench
5) Feed valve 5) Drain saddle 6) Puried water faucet
Otros manuales para ROBUST 1000
1
Este manual sirve para los siguientes modelos
3
Tabla de contenidos
Idiomas:
Otros manuales de Dispensador de agua de Ecosoft