For a 2-Speed fan, PRESS then PRESS to
lower the fan speed to Low (L). PRESS then
PRESS to return to High (H) Speed.
PRESS then PRESS to select
TEMPERATURE CONTROL.
The optional TS3 Outdoor
Temperature Sensor is used
to delay fan operation when
the outdoor temperature is too
warm to provide cooling.
With the two screws provided, attach the base to the wall
with the optional rubber gasket between the wall base.
Center the hole in the base over the drilled hole. Note the
wiring flange on the base is positioned at the bottom.
Install under the eaves of the home, out of direct sunlight,
away from a vent - in a location where the temperature
reading will not be influenced.
Drill a 3/8-inch hole for wiring access.
With the wire nuts provided, attach the two sensor wires to a
2-conductor, 18 or 20 gage, thermostat cable and pass the
cable through the 3/8-inch hole drilled in the wall.
Attach the cover to the base with the screw. Be sure the wire
access opening is at the bottom of the cover.
MODEL 43339
Base
Cover
Rubber Gasket
To Module
Screw attaches cover
to base.
Optional TS3 Outdoor Temperature Sensor
Model RM3
WHF Radio Module
ODT
ODT
Laguna Hills, CA
eControlsUSA.com
TS3 Sensor
RM3 Radio Module
Step 4. Establish Communication Between
RT3 Remote and RM3 Module
Use the pull tab on the back of the RT3
Remote to activate the AAA batteries
already installed. Tilting the remote up will
light the LCD and establish communication
with the RM3.
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) this device may not
Contains Transmitter Module
FCC ID OA3MRF89XAM9A
Ver. X.XX
Model RT3
Wireless Remote Control
Laguna Hills, CA
eControlseControls eControlsUSA.com
Pull Tab
Model RM3
WHF Radio Module
ODT
ODT
Laguna Hills, CA
eControlsUSA.com
The RM3 LED turns solid
green and WL is displayed
on the RT3 once the units
are communicating, usually
within seconds.
Step 6. Checking the Installation
PRESS to turn the fan ON. Fan should be running.
ON/OFF
PRESS then PRESS to select TIMER CONTROL.
MODE
Verify that the fan is running in High speed. For a 3-Speed fan,
PRESS then PRESS to lower the fan speed
to Medium (M). PRESS then PRESS to lower
the fan speed to Low (L). PRESS then PRESS
to return to High (H) speed.
SPEED
CHECK FAN OPERATION
CHECK FAN SPEEDS
SPEED
SPEED
SPEED
SPEED
RETURN TO TEMPERATURE CONTROL
MODE
ON/OFF
Troubleshooting
Ensure that the cable is completely plugged into the
connectors on the RM3 and the FC3J. Ensure the fan is
powered.
LED on RM3 Radio Module not lit.
Ensure that the number of speeds set in Step 5 correspond to
the type of fan installed - 1-speed, 2-speed or 3-speed fan.
check with your installer or the whole house fan manual if
unsure about the type of fan installed.
Fan speeds available seems incorrect.
The RT3 and RM3 are prelinked to each other and are
identified by an ID # on the back of the units. Ensure that the
RT3 and the RM3 ID #s match.
RT3 Remote doesn’t seem to be communicating
2
The RT3 Remote and RM3 Module are
prelinked and automatically establish
communication once the units are powered.
PRESS to turn the fan OFF.
Step 5. Set the Number of Fan Speeds
The RT3 is factory set to a two speed fan. For three-speed or
one-speed fan installations, the number of fan speeds available
needs to be changed to reflect the type of fan installed.
To change the number of speeds, PRESS and HOLD
until the first option is displayed. PRESS again to
display the number of speeds. PRESS to set a 3-speed
fan or PRESS to set a 1-speed fan.
MODE
MODE