Econ P6 Guía rápida


Installation and Instruction Manual
Inverter Air Source Heat Pump


CONTENT
1 Preface 1
3 Specification
5
(3) Unit dimension 8
4 Installation
10
13
5
Operation and Use
6 Appendix
32
2 Safety Precaution
2
(1) Mark notes 2
(2) Icon Notes 2
(3) Warning 3
(1) Appearance and structure of the heat pump
(2) The data of unit
5
6
9
10
10
11
11
12
12
13
27
31
31
11
(1) Application of heat pump
(2) Choose a right heat pump unit
(3) Installation place
(4) Installation method
(5) Water loop connection
(6) Power supply connection
(7) Location of the unit
(8) Transit
(9) Trial Running
(1)
Main interface display and function
(3)
Interface diagram
(1) Appendix 1
(2) Appendix 2
(4) Attention 4
25
(2)
Parameter list and breakdown table
9

The manufacture of this product will not be held responsible if someone is injured or
the unit is damaged, as a result of improper installation, debugging, unnecessary
maintenance which is not in line with this manual.
This manual includes all the necessary information about installation, debugging,
discharging and maintenance. Please read this manual carefully before you open or
maintain the unit.
4 Quiet running
High quality and efficient compressor, fan and water pump is used to ensure the low
noise level with insulation.
5 Good heat exchange rate
The heat pump unit use special designed heat exchanger to enhance whole efficiency.
The unit must be installed by qualified personnel.
The unit can only be opened or repaired by qualified installer or an authorised dealer.
Use genuine standard spare parts only.
Maintenance and operation must be carried out according to the recommended time and
frequency, as stated in this manual.
Failure to comply with these recommendations will invalidate the warranty.
2 Nice appearance
The heat pump is designed with beautiful looking. The monobloc one has the water
pump included which is very easy for installation.
3 Flexible installation
The unit has smart structure with compact body, just simple outdoor installation is needed.
This series of heat pump unit owns following features:
1 Advanced controlling
The PC microcomputer based controller is available for the users to review or set the
running parameters of the heat pump. Centralized controlling system can control several
units by PC.
It is vital that the below instructions are adhered to at all times to keep the warranty.
Inverter ir ource ater eat umpa s w h p is a kind of high efficiency, energy saving and
environment friendly equipment, which is mainly used for house warming. It can work with
any kind of indoor unit such fan coil, radiator, or floor heating pipe, by provide warm or hot
water. One unit of monobloc heat pump can also work with several indoor units.
The air source water heat pump unit is designed to have heat recovery by using super
heater which can provide hot water for sanitary purpose.
6 Large working range
This series of heat pump is designed to work under different working conditions as low
as -15 degrees for heating.
In order to provide the customers with high quality, strong reliability and good versatility
product, this heat pump is produced by strict design and manufacture standards.
Preface
1

Mark
Icon
Meaning
Meaning
A wrongoperation may leadto death orheavy injury on
people.
A wrongoperation may leadto harm onpeople or lossof
material.
Prohibition. What isprohibited will benearby this icon
Compulsory implement. The listed actionneed to betaken.
ATTENTION (include WARNING)
Please pay attentionto what is indicated.
Mark Notes
Icon notes
WARNING
ATTENTION
To prevent the users and others from the harm of this unit, and avoid
damage on the unit or other property, and use the heat pump properly,
please read this manual carefully and understand the following
information correctly.
Safety Precaution
2

The heat pumpmust be installedby qualified personals,
to avoid improperinstallation which canlead to water
leakage, electrical shockor fire.
Please make surethat the unitand power connection
have good earthing,otherwise may causeelectrical shock.
Installation
Professional installer
is required.
Earthing is required
Warning
Safety Precaution
Meaning
Operation Meaning
PROHIBITION
Shut off the power
DO NOT put fingers orothers into thefans and evaporator
of the unit,otherwise harm may be occurred.
When there issomething wrong orstrange smell, thepower
supply need tobe shut off to stopthe unit. Continueto run
may cause electricalshort or fire.
Move and repair
Entrust
Prohibit
Entrust
When the heat pump need to be moved or installed again,
please entrust dealer or qualified person to carry it out.
Improper installation will lead to water leakage, electrical
shock, injury or fire.
It is prohibited to repair the unit by the user himself,
otherwise electrical shock or fire may be occur.
When the heat pump need to be repaired, please entrust
dealer or qualified person to carry it out. Improper movement
or repair on the unit will lead to water leakage, electrical
shock, injury or fire.
Meaning
3
The appliance shallbe stored ina room withoutcontinuously
operating ignition sources(for example:open flames,an
operating gas applianceor an operatingelectric heater.)

Switch off
the power
Prohibition
Please switch off the powerfor clean ormaintenance.
It is prohibitedto use copperor iron asfuse. The right fuse
must be fixed by electrician for the heat pump.
It is prohibitedto spray theflammable gas tothe heat pump,
as it maycause fire.
Installation
Operation
Prohibition
ATTENTION
Check the
installation basement
Please check theinstallation basement ina period (one
month), to avoidany decline ordamage on thebasement,
which may hurtpeople or damagethe unit
Safety Precaution
Meaning
Fix the unit
Installation Place
Need
circuit breaker
The unit CANNOTbe installed near the flammable gas.
Once there isany leakage ofthe gas, firecan be occur.
Make sure thatthe basement ofthe heat pumpis strong
enough, to avoidany decline orfall down ofthe unit
Make sure thatthere is circuitbreaker for theunit, lack of
circuit breaker can lead to electrical shock or fire.
Meaning
4

Specification
1. Appearance and structure of the heat pump
5
P6
The longest distance of installing the
remote controller is 200 meters.
Water intlet tube
Remote Controller
(Manually)
Water outlet tube
The longest distance of installing the
remote controller is 200 meters.
Water intlet tube
Remote Controller
(Manually)
Water outlet tube
P10A/P10T
P17A/P17T
The longest distance of installing the
remote controller is 200 meters.
Water intlet tube
Remote Controller
(Manually)
Water outlet tube

2. The data of unit
Specification
6
*** REFRIGERANT : R32
Cooling working condition:(DB/WB)35 /24 , (Outlet/Inlet) 7 /12 .
Heating working condition:(DB/WB) 7 /6 . (Outlet/Inlet) 35 /30 .
Hot Water working condition: (DB/WB) 20 /15 . Water outlet circulation from 15 to55 .
BS EN 14511-1-2013 Airconditioner, whole liquid cooling machine, electric compressor.
Part2: Test condition Part3:Test method Part4:related requirements.
kW
kW
kW
kW
kW
kW
kW
A
W
RPM
kW
dB(A)
dB(A)
inch
3
m/h
m
mm
mm
kg
kg
P6
1.980 6.100
0.700 2.220
2.290 8.250
0.630 1.810
3.000 9.770
0.600 2.350
2.900
13.0
220~240V
/50Hz
1
Rotary
1
75
850
0.05
48
37~54
1
1.0
5.5
P10T
3.220 11.300
1.270 4.640
4.700 12.50
1.080 3.440
5.760 16.20
1.160 4.200
4.640
7.6
380~415V/3N
~/50Hz
1
Rotary
1
75
850
0.05
52
42~55
1
1.7
5.5
P10A
3.220 11.300
1.270 4.640
4.700 12.50
1.080 3.440
5.760 16.20
1.160 4.200
4.640
21.5
220~240V
/50Hz
1
Rotary
1
93
1050
0.05
52
42~55
1
1.7
5.5
P17A
5.500 15.50
1.500 6.000
7.000 20.50
1.500 6.000
9.350 24.30
2.060 6.400
7.200
33.2
220~240V
/50Hz
1
Rotary
2
110
850
0.18
55
44~58
1 1/4
2.9
12.5
P17T
5.500 15.50
1.500 6.000
7.000 20.50
1.500 6.000
9.350 24.30
2.060 6.400
7.200
12.0
380-415V/3N
~/50Hz
1
Rotary
2
110
850
0.18
55
44~58
1 1/4
2.9
12.5
See drawings of theheat pump
see data on thepackage
see data on thenameplate
see data on thepackage
P24T
The longest distance of installing the
remote controller is 200 meters.
Water intlet tube
Remote Controller
(Manually)
Water outlet tube
P24T
6.400 15.80
3.400 6.800
10.00 25.00
2.800 5.700
14.30 28.10
3.400 7.000
12.80
20.5
380-415V/3N
~/50Hz
1
Rotary
2
150
850
0.5
59
53~59
1 1/4
4.2
21
Este manual sirve para los siguientes modelos
5
Tabla de contenidos
Manuales populares de Bomba de calor de otras marcas

Mitsubishi Electric
Mitsubishi Electric PUZ-SWM60VAA Manual de usuario

Dimplex
Dimplex LI 16I-TUR Guía del usuario

Carrier
Carrier WSHP Open v3 Guía de configuración rápida

TGM
TGM CTV14CN018A Manual de usuario

Carrier
Carrier 38MGQ Series Manual de usuario

Kokido
Kokido K2O K880BX/EU Guía de solución de problemas

Viessmann
Viessmann VITOCAL 300-G PRO Type BW 2150 Guía rápida

Carrier
Carrier 48EZN Manual de usuario

Viessmann
Viessmann KWT Vitocal 350-G Pro Series Instrucciones de funcionamiento

Ariston
Ariston NIMBUS Manual de usuario

Weishaupt
Weishaupt WWP L 7 Guía del usuario

GE
GE Zoneline AZ85H09EAC Manual de usuario