Maintenance
-7-
Settings before first use:
1.Check the current
When the wiring are correctly done, if the current parameter is not zero when it is not
charged or discharged, then you need to press the zero button at the PARAME page to
clear the current current parameter.
2.Set the battery parameters
Set the battery “Nominal Capacity” and “Full Capacity Voltage” in the blue column of
“Parameter Setting Page”.
(Note: "Full Capacity Voltage" is recommended to be the highest voltage displayed when
the battery is fully charged and the charger is not unplugged yet.)
3.Charge the battery to full
After connecting the cable and setting the parameters, the monitoring page will not show
the battery capacity immediately. At this time, the battery capacity is still empty, and you
need to charge the battery to full for once so that the monitor could display the power
normally.
1. The voltage and current can not exceed the rated range of the monitor, otherwise it will
be damaged.
2. Positive and negative poles can not be connected in reverse, or the measurement will
be incorrect.
3. Place the monitor in a dry and cool environment, operating temperature is -10 ~ 50℃,
storage temperature is -20 ~ 70℃.
4. Do not try to disassemble the monitor, damage to the case will lead to warranty failure.
There is no module inside this monitor that can be repaired by the users.
5. When the monitor is working, please do not move the monitor violently to avoid irrepa-
rable damage to the internal circuit.