Ebyte E810-DTU Manual de usuario

E810-DTU(CAN-RS485)
Intelligent Protocol Converter

Chengdu Ebyte Electronic Technology Co.,LTD E810-DTU(CAN-RS485) User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd. 2
Contents
1. OVERVIEW..................................................................................................................................... 4
1.1 Brief Introduction........................................................................................................................................................... 4
1.2 Feature............................................................................................................................................................................. 4
1.3 Application...................................................................................................................................................................... 4
2. TECHNICAL PARAMETERS AND SPECIFICATION............................................................ 5
2.1 Basic parameter.............................................................................................................................................................. 5
2.2 Factory default parameter............................................................................................................................................. 5
3 HARDWARE DESIGN INTRODUCTION................................................................................... 6
3.1 Design introduction.........................................................................................................................................................6
3.2 Dimension....................................................................................................................................................................... 8
3.3 Connection method......................................................................................................................................................... 9
3.3.1 RS485 connection method.........................................................................................................................................9
3.3.2 CAN connection method......................................................................................................................................... 10
4 MODE INTRODUCTION.............................................................................................................10
4.1 Operating mode.............................................................................................................................................................10
4.2 Data conversion method...............................................................................................................................................10
4.2.1Transparent conversion mode...................................................................................................................................11
4.2.2 Transparent band information conversion............................................................................................................... 14
4.2.3 Protocol mode..........................................................................................................................................................17
4.2.4 Modbus mode.......................................................................................................................................................... 19
5 OPERATION INSTRUCTIONS...................................................................................................22
5.1 Entering Command Configuration Instructions....................................................................................................... 22
5.2 Command overview...................................................................................................................................................... 22
5.3 Command error code....................................................................................................................................................22

Chengdu Ebyte Electronic Technology Co.,LTD E810-DTU(CAN-RS485) User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd. 3
5.4 Command list................................................................................................................................................................ 23
5.5 Command details.......................................................................................................................................................... 23
5.5.1 AT test command................................................................................................................................................... 23
5.5.2 AT+CANFLT Inquire/set CAN filter info............................................................................................................ 23
5.5.3 AT+CAN inquire/set transmitted CAN parameter info...........................................................................................24
5.5.4 AT+EXAT exit AT command..................................................................................................................................24
5.5.5 AT+E inquire/set command echo mode...................................................................................................................24
5.5.6 AT+MODBUSID inquire/set MODBUS ID........................................................................................................... 25
5.5.7 AT+MODE inquire/set operating mode................................................................................................................ 25
5.5.8 AT+MID inquire device name................................................................................................................................ 25
5.5.9 AT+RESTORE restore factory default setting....................................................................................................... 26
5.5.10 AT+REBT reset device.......................................................................................................................................... 26
5.5.11 AT+UARTPKT inquire/set UART sub=packing info........................................................................................... 26
5.5.12 AT+UART inquire/set UART parameter...............................................................................................................26
5.5.13 AT+VER inquire module version info..................................................................................................................27
6 FAQ..................................................................................................................................................27
6.1 Module is easy to damage.............................................................................................................................................27
6.2 Unable to successfully set the command..................................................................................................................... 27
6.3 Unable to use after parameter is changed.................................................................................................................. 27
REVISION HISTORY...................................................................................................................... 28
ABOUT US......................................................................................................................................... 28

Chengdu Ebyte Electronic Technology Co.,LTD E810-DTU(CAN-RS485) User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd. 4
1. Overview
1.1 Brief Introduction
E810-DTU (CAN-RS485) is a small intelligent protocol converter developed by
Chengdu Ebyte Electronic Technology Co., Ltd. It is with 8V ~ 28V of power supply,
integrating 1 channel CAN-BUS interface and 1 channel RS485 interface to realize
bidirectional conversion between different protocol data from RS485 and CAN. It supports
serial command configuration device parameters and working mode, and there are four data
conversion modes available: transparent conversion, transparent band information conversion,
protocol conversion, and Modbus RTU conversion. At the same time, E810-DTU (CAN-
RS485) intelligent protocol converter has the characteristics of small size and convenient
installation. It has high cost performance in CAN-BUS product development and data
analysis applications. It is reliable assistant for engineering application, project debugging and product development.
1.2 Feature
Bidirectional conversion of data between RS485 and CAN is available.
Transparent conversion, transparent band information conversion and protocol conversion are available.
Modbus RTU protocol conversion is available.
Support two CAN identifier transmission methods, which can be specified by fixed configuration or serial frame data.
Parameter setting via RS485 is available.
Parameter setting via RS485 is between 1200~115200.
Parameter setting via software is available.
Factory setting reset via software and hardware is available.
With power indicator, status indicator, etc.
1.3 Application
Industrial control and other CAN-BUS networks
Automobile and railway equipment networking
Security and fire protection network
Underground remote communication
Public address system
Parking equipment control
Smart home, smart building

Chengdu Ebyte Electronic Technology Co.,LTD E810-DTU(CAN-RS485) User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd. 5
2. Technical Parameters and Specification
2.1 Basic parameter
Main parameter
Value
Power supply
8V ~28V ,12V or 24V is recommended (Voltage over 28V will cause
permanent damage)
Operating current
38.2762mA@12V(RS485)
Operating temperature
-40℃~85℃
Interface
RS485:1*5*3.81,screwing;CAN:1*4*3.81,screwing
Communication level
3.3V,or 5V,level switch is required
Operating humidity
10%~90%,relative humidity, no condensation
2.2 Factory default parameter
RS485
Serial baud rate
115200 bps
Parity
None
Data bit
8
Stop bit
1
Flow control
Off
CAN
CAN baud rate
100K bps
CAN ID
0x00000000
Flow control
Off
Default operating mode
Transparent transmission mode
Receive all kinds of data
Default device address
Modbus device address
Default device address is 1
Frame sub-packing parameter
Time
10ms
Byte
1000byte

Chengdu Ebyte Electronic Technology Co.,LTD E810-DTU(CAN-RS485) User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd. 6
3 Hardware design introduction
3.1 Design introduction

Chengdu Ebyte Electronic Technology Co.,LTD E810-DTU(CAN-RS485) User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd. 7
NO.
Item
Application
1
VCC
Power supply, default : 8-28V, 12V or 24V is recommended
(standard 5V can be customized )
2
GND
Ground
3
GNDA
RS485 common port,connecting to GND of other RS485 device
4
485_A
RS485, Data A
5
485_B
RS485, Data B
6
PWR
Power indicator
7
TX
Serial port TX indicator
8
RX
Serial port RX indicator
9
RL
Restore factory settings indicator, press DTU for 5-10S to restore factory
settings
10
STE
Status indicator
11
GNDA
Signal reference ground
12
GNDA
Signal reference ground
13
CAN-H can H
CAN communication interface
14
CAN-L can L
CAN communication interface

Chengdu Ebyte Electronic Technology Co.,LTD E810-DTU(CAN-RS485) User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd. 8
3.2 Dimension

Chengdu Ebyte Electronic Technology Co.,LTD E810-DTU(CAN-RS485) User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd. 9
3.3 Connection method
3.3.1 RS485 connection method

Chengdu Ebyte Electronic Technology Co.,LTD E810-DTU(CAN-RS485) User Manual
Copyright ©2012–2019,Chengdu Ebyte Electronic Technology Co., Ltd. 10
3.3.2 CAN connection method
4 Mode introduction
4.1 Operating mode
There are two modes for E810-DTU(CAN-RS485),normal and parameter setting mode.
Mode
Function
Normal mode
The general mode of the device is normal mode, and it works
normally when it is powered on.
Setting mode
The device can be configured in the mode. For details on how to
enter the configuration mode, see Chapter 5.
4.2 Data conversion mode
There are four data conversion modes for E810-DTU(CAN-RS485) :Transparent conversion, transparent band information
conversion, protocol conversion and MODBUS conversion. Bidirectional conversion between CAN and RS485 is available.
Data conversion mode
Conversion direction
Transparent conversion
Bidirectional conversion between CAN
and RS485
Transparent band information
conversion
Bidirectional conversion between CAN
and RS485
Protocol conversion
Bidirectional conversion between CAN
and RS485
MODBUS conversion
Bidirectional conversion between CAN
and RS485
Otros manuales para E810-DTU